Learning curve using the second-generation cryoballoon ablation
Authors:
- Carlo de AsmundisCarlo de Asmundis
- Giacomo MugnaiGiacomo Mugnai
- Burak HünükBHBurak Hünük
- Ebru HacioğluEHEbru Hacioğlu
- Erwin StrökerESErwin Ströker
- Darragh MoranDMDarragh Moran
- Diego RuggieroDRDiego Ruggiero
- Jan PoelaertJan Poelaert
- Christian VerborghCVChristian Verborgh
- Vincent UmbrainVUVincent Umbrain
- Gaetano PaparellaGPGaetano Paparella
- 1 July 2017
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cardiovascular Medicine
- Vol. 18 (7) , 518-527
Abstract
To study the learning curve with the second-generation cryoballoon technology focusing on safety, efficacy and procedural characteristics. We included 300 patients (men 64.6%, mean age 58.3 ± 12.4 years), 240 of whom were treated by four operators without prior experience in atrial fibrillation ablation and compared them with 60 consecutive patients treated by senior operator. To study the learning curves, we divided the study period into two trimesters and analyzed procedure duration, fluoroscopy times, complications, characteristics of the freeze–thaw cycles and midterm outcomes. Hands-on help from senior operators to achieve pulmonary vein isolation was needed only in the first study trimester (24.1%), most commonly to achieve right inferior pulmonary vein isolation (55.2%). The mean procedure duration shortened from 76.7 ± 17.4 to 65.1 ± 11.4 min (P < 0.0001), and fluoroscopy time decreased from 18.5 ± 7.3 to 12.1 ± 4.3 min (P < 0.0001) for first and second trimester, respectively, and approached senior operator's results (58.2 ± 12.8 and 8.7 ± 4.5 min). Most of the major complications (one stroke, four pseudoaneurysms and one retroperitoneal hematoma) occurred during the first study trimester. Most characteristics of the freeze cycles remained unchanged in both study periods. Compared with junior operators, the senior operator achieved lower nadir temperatures in both inferior veins. However, there was no significant difference in midterm outcomes between junior and senior operators (79.5 vs 83.3%, P = 0.589). The learning curve with the second-generation cryoballoon is steep. Inexperienced operators, trained in high-volume centers, can achieve pulmonary vein isolation safely and efficiently with short procedure and fluoroscopy times after having performed 20–30 cases.Keywords
This publication has 25 references indexed in Scilit:
- Immediate balloon deflation for prevention of persistent phrenic nerve palsy during pulmonary vein isolation by balloon cryoablationHeart Rhythm, 2013
- Cryoballoon Ablation of Pulmonary Veins for Paroxysmal Atrial FibrillationJACC, 2013
- Long-Term Outcomes After Cryoballoon Pulmonary Vein IsolationJACC, 2013
- Improved Procedural Efficacy of Pulmonary Vein Isolation Using the Novel Second‐Generation CryoballoonJournal of Cardiovascular Electrophysiology, 2012
- ESC-EURObservational Research Programme: the Atrial Fibrillation Ablation Pilot Study, conducted by the European Heart Rhythm AssociationEP Europace, 2012
- 2012 HRS/EHRA/ECAS Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: Recommendations for Patient Selection, Procedural Techniques, Patient Management and Follow-up, Definitions, Endpoints, and Research Trial DesignA report of the Heart Rhythm Society (HRS) Task Force on Catheter and Surgical Ablation of Atrial Fibrillation. Developed in partnership with the European Heart Rhythm Association (EHRA), a registered branch of the European Society of Cardiology (ESC) and the European Cardiac Arrhythmia Society (ECAS); and in collaboration with the American College of Cardiology (ACC), American Heart Association (AHA), the Asia Pacific Heart Rhythm Society (APHRS), and the Society of Thoracic Surgeons (STS). Endorsed by the governing bodies of the American College of Cardiology Foundation, the American Heart Association, the European Cardiac Arrhythmia Society, the European Heart Rhythm Association, the Society of Thoracic Surgeons, the Asia Pacific Heart Rhythm Society, and the Heart Rhythm SocietyEP Europace, 2012
- Influence of the anatomic characteristics of the pulmonary vein ostium, the learning curve, and the use of a steerable sheath on success of pulmonary vein isolation with a novel multielectrode ablation catheterEP Europace, 2011
- Reduced fluoroscopy exposure during ablation of atrial fibrillation using a novel electroanatomical navigation system: a multicentre experienceEP Europace, 2011
- Efficacy and safety of cryoballoon ablation for atrial fibrillation: A systematic review of published studiesHeart Rhythm, 2011
- Recovered Pulmonary Vein Conduction as a Dominant Factor for Recurrent Atrial Tachyarrhythmias After Complete Circular Isolation of the Pulmonary VeinsCirculation, 2005