Blast flagging of the Sysmex XN‐10 hematology analyzer with supervised cell image analysis: Impact on quality parameters
- 4 June 2019
- journal article
- research article
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 41 (5) , 601-606
Abstract
Introduction: The Sysmex XN‐10 automated hematology analyzer (Sysmex Corporation) is routinely used in hematology laboratories to perform complete blood cell count with differential (CBC w/ diff). The sensitivity of this system for blast detection is unclear, since many prior studies evaluating the blast flagging capabilities of Sysmex XN series used the white precursor cell (WPC) channel, which is not cleared for use in the United States.Methods: We assessed the blast flagging capabilities of the Sysmex XN‐10 compared with CellaVision (a cell image analyzer)‐assisted visual hematology results. We evaluated the following flags: “blasts?/abnormal lymph?” and “immature granulocytes present” and compared differences in turnaround time between methods.Results: We collected data on 2239 CBC w/ diff Sysmex automated analyzer differential and CellaVision‐assisted visual differential from the inpatient hematology‐oncology population of a tertiary care medical center. Solely analyzing the first CBC/diff from each unique patient, both flags had a combined sensitivity of 100%, specificity of 50.2%, PPV of 21.7%, and NPV of 100%. The mean turnaround time for the automated differential was 19.5 minutes (SD 35.9 minutes) compared with 66.4 minutes for the CellaVision‐assisted visual differential (SD 68.5 minutes; P < 0.001; Figure 1).Conclusion: The Sysmex XN‐10 abnormal lymphocyte/blast and immature granulocytes flags had excellent sensitivity and acceptable specificity in detecting circulating blasts with shorter turnaround time than the CellaVision‐assisted visual differential. Our study suggests that automated differentials performed on Sysmex XN‐10 can replace visual differentials as a first‐line screening method for blast detection with improved turnaround time in hematology‐oncology populations.Keywords
This publication has 15 references indexed in Scilit:
- Decreased sensitivity of the automatic white precursor cell channel (WPC) for blast flagging in patients with leukopeniaClinical Biochemistry, 2016
- The value of the white precursor cell channel (WPC) on the Sysmex XN-1000 analyser in a specialist paediatric hospitalJournal of Clinical Pathology, 2014
- Do the Flags Related to Immature Granulocytes Reported by the Sysmex XE-5000 Warrant a Microscopic Slide Review?American Journal of Clinical Pathology, 2014
- Performance evaluation of the new hematology analyzer Sysmex XN‐seriesInternational Journal of Laboratory Hematology, 2014
- Optimal flagging combinations for best performance of five blood cell analyzersInternational Journal of Laboratory Hematology, 2014
- A Survey Study of Benefits and Limitations of using CellaVision™ DM96 for Peripheral Blood DifferentialsAmerican Society for Clinical Laboratory Science, 2014
- Performance and Abnormal Cell Flagging Comparisons of Three Automated Blood Cell CountersAmerican Journal of Clinical Pathology, 2013
- Comparison of Automated Differential Blood Cell Counts From Abbott Sapphire, Siemens Advia 120, Beckman Coulter DxH 800, and Sysmex XE-2100 in Normal and Pathologic SamplesAmerican Journal of Clinical Pathology, 2013
- Improved Flagging Rates on the Sysmex XE-5000 Compared With the XE-2100 Reduce the Number of Manual Film Reviews and Increase Laboratory ProductivityAmerican Journal of Clinical Pathology, 2011
- Can automated blood film analysis replace the manual differential? An evaluation of the CellaVision DM96 automated image analysis systemInternational Journal of Laboratory Hematology, 2009