Ronald Jackups
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ronald Jackups has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Chancey Christenson
Department of Laboratory Medicine and Pathology, Mayo Clinic, Jacksonville, FL, United States
1 shared publicationCharles S. Eby
Department of Pathology and Immunology, Washington University School of Medicine, St. Louis, Missouri
1 shared publication- Chen Yang
Department of Pathology, Yale School of Medicine, Yale University, New Haven, USA
1 shared publication - David S. McClintock
Department of Laboratory Medicine and Pathology, Division of Computational Pathology and Informatics, Mayo Clinic , Rochester, MN
1 shared publication Gail Shimer
Clinical Hematology Laboratory, Barnes-Jewish Hospital, St. Louis, Missouri
1 shared publicationJeanne Anderson
Clinical Hematology Laboratory, Barnes-Jewish Hospital, St. Louis, Missouri
1 shared publication
Latest Publications
- Open Access
- 1 October 2023
- Published by Elsevier in Journal of Pathology Informatics
- Vol. 14, 100338
Organizational preparedness for the use of large language models in pathology informatics
- 1 October 2023
- Published by Elsevier in Journal of Pathology Informatics
- Vol. 14, 100338
Open AccessOrganizational preparedness for the use of large language models in pathology informatics
- 22 March 2021
- Published by Elsevier in Journal of Biomedical Informatics
- Vol. 117, 103756
Using information theory to optimize a diagnostic threshold to match physician-ordering practice
- 22 March 2021
- Published by Elsevier in Journal of Biomedical Informatics
- Vol. 117, 103756
Using information theory to optimize a diagnostic threshold to match physician-ordering practice
- 4 June 2019
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 41 (5) , 601-606
Blast flagging of the Sysmex XN‐10 hematology analyzer with supervised cell image analysis: Impact on quality parameters
Introduction: The Sysmex XN‐10 automated hematology analyzer (Sysmex Corporation) is routinely used in hematology laboratories to perform complete blood cell count with differential (CBC w/ diff). The sensitivity of this system for blast detection is unclear, since many prior studies evaluating the blast flagging capabilities of Sysmex XN series used the white precursor cell (WPC) channel, which is not cleared for use in the United States.Methods: We assessed the blast flagging capabilities of the Sysmex XN‐10 compared with CellaVision (a cell image analyzer)‐assisted visual hematology results. We evaluated the following flags: “blasts?/abnormal lymph?” and “immature granulocytes present” and compared differences in turnaround time between methods.Results: We collected data on 2239 CBC w/ diff Sysmex automated analyzer differential and CellaVision‐assisted visual differential from the inpatient hematology‐oncology population of a tertiary care medical center. Solely analyzing the first CBC/diff from each unique patient, both flags had a combined sensitivity of 100%, specificity of 50.2%, PPV of 21.7%, and NPV of 100%. The mean turnaround time for the automated differential was 19.5 minutes (SD 35.9 minutes) compared with 66.4 minutes for the CellaVision‐assisted visual differential (SD 68.5 minutes; P < 0.001; Figure 1).Conclusion: The Sysmex XN‐10 abnormal lymphocyte/blast and immature granulocytes flags had excellent sensitivity and acceptable specificity in detecting circulating blasts with shorter turnaround time than the CellaVision‐assisted visual differential. Our study suggests that automated differentials performed on Sysmex XN‐10 can replace visual differentials as a first‐line screening method for blast detection with improved turnaround time in hematology‐oncology populations.
- 4 June 2019
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 41 (5) , 601-606
Blast flagging of the Sysmex XN‐10 hematology analyzer with supervised cell image analysis: Impact on quality parameters
Introduction: The Sysmex XN‐10 automated hematology analyzer (Sysmex Corporation) is routinely used in hematology laboratories to perform complete blood cell count with differential (CBC w/ diff). The sensitivity of this system for blast detection is unclear, since many prior studies evaluating the blast flagging capabilities of Sysmex XN series used the white precursor cell (WPC) channel, which is not cleared for use in the United States.Methods: We assessed the blast flagging capabilities of the Sysmex XN‐10 compared with CellaVision (a cell image analyzer)‐assisted visual hematology results. We evaluated the following flags: “blasts?/abnormal lymph?” and “immature granulocytes present” and compared differences in turnaround time between methods.Results: We collected data on 2239 CBC w/ diff Sysmex automated analyzer differential and CellaVision‐assisted visual differential from the inpatient hematology‐oncology population of a tertiary care medical center. Solely analyzing the first CBC/diff from each unique patient, both flags had a combined sensitivity of 100%, specificity of 50.2%, PPV of 21.7%, and NPV of 100%. The mean turnaround time for the automated differential was 19.5 minutes (SD 35.9 minutes) compared with 66.4 minutes for the CellaVision‐assisted visual differential (SD 68.5 minutes; P < 0.001; Figure 1).Conclusion: The Sysmex XN‐10 abnormal lymphocyte/blast and immature granulocytes flags had excellent sensitivity and acceptable specificity in detecting circulating blasts with shorter turnaround time than the CellaVision‐assisted visual differential. Our study suggests that automated differentials performed on Sysmex XN‐10 can replace visual differentials as a first‐line screening method for blast detection with improved turnaround time in hematology‐oncology populations.
- 5 April 2018
- Published by American Society of Hematology in Blood
- Vol. 131 (14) , 1626
Abnormalities of platelet aggregation associated with giant granules in a subset of platelets
- 5 April 2018
- Published by American Society of Hematology in Blood
- Vol. 131 (14) , 1626
Abnormalities of platelet aggregation associated with giant granules in a subset of platelets