Fire resistance of partially encased composite columns subjected to eccentric loading
- 11 January 2022
- journal article
- research article
- Published by Emerald Publishing in Journal of Structural Fire Engineering
- Vol. 13 (4) , 451-469
Abstract
Purpose: Investigate the fire performance of eccentrically loaded concrete partially encased column (PEC), using the advanced calculation method (ANSYS 18.2, 2017) and the simple calculation method in Annex G of Eurocode 4 (EN 1994-1-2, 2005). This work examines the influence of a range of parameters on fire behaviour of the composite column including: eccentricity loading, slenderness, reinforcement, fire rating and fire scenario. In this study, ISO-834 (ISO834-1, 1999) was used as fire source.Design/methodology/approach: Currently, different methods of analysis used to assess the thermal behaviour of composite column exposed to fire. Analytical method named simplified calculation methods defined in European standard and numerical simulations named advanced calculation models are treated in this paper.Findings: The load-bearing capacity of the composite column becomes very weak in the presence of the fire accident and eccentric loading, this recommends to avoid as much as possible eccentric loading during the design of construction building. The reinforcement has a slight influence on the temperature evolution; moreover, the reinforcement has a great contribution on the load capacity, especially in combined compression and bending. When only the two concrete sides are exposed to fire, the partially encased composite column presents a high load-bearing capacity value.Originality/value: The use of a three-dimensional numerical model (ANSYS) allowed to describe easily the thermal behaviour of PEC columns under eccentric loading with the regard to the analytical method, which is based on three complex steps. In this study, the presence of the load eccentricity has found to have more effect on the load-bearing capacity than the slenderness of the composite column. Introducing a load eccentricity on the top of the column may have the same a reducing effect on the load-bearing capacity as the fire.Keywords
This publication has 25 references indexed in Scilit:
- Experimental investigation of the fire resistance of partially encased beamsJournal of Constructional Steel Research, 2013
- State of the art on the time-dependent behaviour of composite steel–concrete structuresJournal of Constructional Steel Research, 2013
- Fire resistance of partially encased steel columns with restrained thermal elongationJournal of Constructional Steel Research, 2011
- Fire resistance of concrete encased steel columns under 3- and 4-side standard heatingJournal of Constructional Steel Research, 2011
- Experimental behavior of steel beam–columns subjected to fire-induced thermal gradientsJournal of Constructional Steel Research, 2011
- Investigation of concrete encased steel composite columns at elevated temperaturesThin-Walled Structures, 2010
- Analytical modeling of the standard fire behavior of loaded CFT columnsJournal of Constructional Steel Research, 2009
- Fire resistance of composite columns with embedded I-section steel — Effects of section size and load levelJournal of Constructional Steel Research, 2008
- A numerical imperfection sensitivity study of cold-formed thin-walled tubular steel columns at uniform elevated temperaturesThin-Walled Structures, 2004
- Fire Resistance of Concrete‐Filled, Fire‐Resistant Steel‐Tube ColumnsJournal of Materials in Civil Engineering, 1994