Detection of Quiescent Cardiac Phases in Echocardiography Data Using Nonlinear Filtering and Boundary Detection Techniques
Open Access
- 24 May 2014
- journal article
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 27 (5) , 625-632
Abstract
We describe an algorithm to detect cardiac quiescence within a heartbeat using nonlinear filtering and boundary detection techniques in echocardiography images. The motivation for detection of these quiescent phases is to provide improved cardiac gating to obtain motion-artifact-free images of the heart at cardiac computed tomography (CT). Currently, cardiac gating is provided through electrocardiography (ECG), which does not provide information about the instantaneous mechanical state of the heart. Our goal is to test if information about the actual mechanical motion of the heart obtained from B-mode echocardiographic data could potentially be used for gating purposes. The nonlinear filtering algorithm presented involves anisotropic diffusion to smoothen the homogeneous regions of the B-mode images while preserving image edges that represent myocardial boundaries. Following this, we detect the boundary of a particular region of interest (ROI) using a thresholding step. The positional changes of this ROI are then observed for quiescent phases over multiple cardiac cycles using the ECG’s R-R interval. In a pilot study, seven subjects were imaged in the apical, four-chamber view, and quiescence of the interventricular septum was primarily observed in the diastolic region of the ECG signal. However, the position and length of quiescence vary across multiple heartbeats for the same individual and for different individuals as well. The center of quiescence for the seven patients ranged from 51 to 84 % and did not show a trend with heart rates, which ranged from 54 to 83 beats per minute. The gating intervals based on such analysis of echocardiographic signals could potentially optimize cardiac CT gating.Keywords
This publication has 20 references indexed in Scilit:
- Heart Disease and Stroke Statistics—2013 UpdateCirculation, 2013
- A Half Century of Selective Coronary ArteriographyJACC, 2009
- Assessment of Coronary Artery Disease by Cardiac Computed TomographyCirculation, 2006
- Speckle reducing anisotropic diffusionIEEE Transactions on Image Processing, 2002
- Optimal ECG Trigger Point in Electron-Beam CT StudiesAcademic Radiology, 2001
- Noninvasive Coronary Angiography by Retrospectively ECG-Gated Multislice Spiral CTCirculation, 2000
- Nonlinear anisotropic filtering of MRI dataIEEE Transactions on Medical Imaging, 1992
- Adaptive restoration of images with speckleIEEE Transactions on Acoustics, Speech, and Signal Processing, 1987
- Speckle Suppression And Analysis For Synthetic Aperture Radar ImagesOptical Engineering, 1986
- Refined filtering of image noise using local statisticsComputer Graphics and Image Processing, 1981