CWCarson A. Wick

Carson A. Wick

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Carson A. Wick has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Detection of Quiescent Cardiac Phases in Echocardiography Data Using Nonlinear Filtering and Boundary Detection Techniques

    by Lakshminarayan Ravichandran, Carson A. Wick, James H. McClellan, Tian Liu, Srini Tridandapani

    We describe an algorithm to detect cardiac quiescence within a heartbeat using nonlinear filtering and boundary detection techniques in echocardiography images. The motivation for detection of these quiescent phases is to provide improved cardiac gating to obtain motion-artifact-free images of the heart at cardiac computed tomography (CT). Currently, cardiac gating is provided through electrocardiography (ECG), which does not provide information about the instantaneous mechanical state of the heart. Our goal is to test if information about the actual mechanical motion of the heart obtained from B-mode echocardiographic data could potentially be used for gating purposes. The nonlinear filtering algorithm presented involves anisotropic diffusion to smoothen the homogeneous regions of the B-mode images while preserving image edges that represent myocardial boundaries. Following this, we detect the boundary of a particular region of interest (ROI) using a thresholding step. The positional changes of this ROI are then observed for quiescent phases over multiple cardiac cycles using the ECG’s R-R interval. In a pilot study, seven subjects were imaged in the apical, four-chamber view, and quiescence of the interventricular septum was primarily observed in the diastolic region of the ECG signal. However, the position and length of quiescence vary across multiple heartbeats for the same individual and for different individuals as well. The center of quiescence for the seven patients ranged from 51 to 84 % and did not show a trend with heart rates, which ranged from 54 to 83 beats per minute. The gating intervals based on such analysis of echocardiographic signals could potentially optimize cardiac CT gating.


  • Open Access

    Remotely Accessible Instrumented Monitoring of Global Development Programs: Technology Development and Validation

    by Evan A. Thomas, Zdenek Zumr, Jodi Graf, Carson A. Wick, James H. McCellan, Zachary Imam, Christina Barstow, Kelly Spiller, Michael Fleming

    Many global development agencies self-report their project outcomes, often relying on subjective data that is collected sporadically and communicated months later. These reports often highlight successes and downplay challenges. Instrumented monitoring via distributed data collection platforms may provide crucial evidence to help inform the sector and public on the effectiveness of aid, and the on-going challenges. This paper presents the process of designing and validating an integrated sensor platform with cellular-to-internet reporting purposely targeted at global development programs. The integrated hardware platform has been applied to water, sanitation, energy and infrastructure interventions and validated through laboratory calibration and field observations. Presented here are two examples: a water pump and a household water filter, wherein field observations agreed with the data algorithm with a linear fit slope of between 0.91 and 1, and an r-squared of between 0.36 and 0.39, indicating a wide confidence interval but with low overall error (i.e., less than 0.5% in the case of structured field observations of water volume added to a household water filter) and few false negatives or false positives.


  • An active contour based method for analyzing cardiac quiescence from echocardiography

    by Carson A. Wick, James H. McClellan, Lakshminarayan Ravichandran, Srini Tridandapani

    A semi-automated method for analyzing cardiac quiescence of anatomical cardiac features from two-dimensional echocardiographic cine data is presented. The method utilizes both active contour and optical flow techniques for feature identification and tracking. A curvature-based potential surface was used in the active contour calculations to attract the contour to regions of inflection on the image surface rather than the standard gradient-based surface that attracts the contour to strong edges. After identifying the feature in each frame, the frame-to-frame correlation matrix of the feature was calculated with correlation values corresponding to how well the feature matched between frames. Therefore prolonged regions of high correlation correspond to periods of cardiac quiescence. The location and duration of these periods were automatically identified from the correlation matrix by finding the largest region around each time index with a mean correlation above a specified threshold. In parallel, the position of the feature was calculated for each frame by finding the centroid of the pixel locations inside the contour. From this trajectory, the magnitude of the two-dimensional velocity was calculated. These methods were used to analyze the quiescence of the interventricular septum from an apical four-chamber echocardiogram performed on a human subject. Correlation-derived quiescent phases were observed to coincide with periods of the cardiac cycle with minimal velocity magnitude.


  • Open Access

    Detection of quiescent phases in echocardiography data using non-linear filtering and boundary detection

    by Lakshminarayan Ravichandran, Carson A. Wick, Srini Tridandapani

    In order to detect the quasi-stationary states of the heart within a cardiac cycle from echocardiography data, we present an algorithm that uses non-linear filtering and boundary detection. The non-linear filtering algorithm involves anisotropic diffusion to remove the speckle noise from the data and to smoothen the homogeneous regions while preserving the edges. Following this, we perform binary thresholding and boundary detection, and observe the positional changes in the region of interest. From a series of echocardiography images, we derived the regions of cardiac quiescence, which we then plotted on the electrocardiograph (ECG) R-R interval. It is observed that the quiescence occurs in the diastolic region of the ECG signal, but the position and length of quiescence varies across multiple cardiac cycles for the same individual.