Higher spatial resolution and sensitivity in whole brain functional MRI at 7T using 3D EPI accelerated with variable density CAIPI sampling and temporal random walk
- 24 April 2025
- journal article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (2) , 678-693
Abstract
Purpose: To develop an efficient 3D EPI encoding technique for high spatiotemporal resolution functional MRI. Methods: To exploit spatiotemporal fMRI data structure, we introduce a variable density 2D CAIPI sampling in the spatial domain combined with time‐wise extra random encoding in the time domain, thus achieving pseudo‐regular sampling with a regular blip while allowing incoherent sampling in a complementary manner across time. This enabled temporally regularized reconstruction of highly accelerated functional data acquisition. The encoding scheme was then validated against temporally invariant CAIPI encoding by applying to locally confined and whole‐brain around the primary visual cortex, respectively, with increasing the spatial resolutions. Results: For partial brain imaging, our proposed method achieved higher reconstruction accuracy, resulting in a substantial increase of SSIM compared to an alternative method for 0.64 mm‐isotropic resolution. When used for whole brain imaging at 0.56 mm‐isotropic resolution, our method showed a decreased spatial extent of activation and produced high‐quality images for a clear distinction between activated and non‐activated regions around calcarine fissure with high spatial specificity. Conclusion: The proposed 3D EPI encoding scheme, which exploits coherent and incoherent sampling properties, can significantly improve the image quality while providing a good balance between sensitivity and specificity in the activated regions.Keywords
Funding Information
- National Research Foundation of Korea (RS‐2024‐00357917)
This publication has 48 references indexed in Scilit:
- High temporal resolution functional MRI using parallel echo volumar imagingJournal of Magnetic Resonance Imaging, 2008
- Compressed sensing in dynamic MRIMagnetic Resonance in Medicine, 2008
- Improved echo volumar imaging (EVI) for functional MRIMagnetic Resonance in Medicine, 2006
- Controlled aliasing in volumetric parallel imaging (2D CAIPIRINHA)Magnetic Resonance in Medicine, 2006
- Microvascular BOLD contribution at 4 and 7 T in the human brain: Gradient‐echo and spin‐echo fMRI with suppression of blood effectsMagnetic Resonance in Medicine, 2003
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Phase errors in multi‐shot echo planar imagingMagnetic Resonance in Medicine, 1994
- Functional MRI of human brain activation at high spatial resolutionMagnetic Resonance in Medicine, 1993
- Oxygenation‐sensitive contrast in magnetic resonance image of rodent brain at high magnetic fieldsMagnetic Resonance in Medicine, 1990