Latest Publications

  • In Vivo Meso‐Scale Whole‐Brain Quantitative Imaging With Tailored MRF on the NexGen 7T Scanner

    by Xiaozhi Cao, Alexander Beckett, Congyu Liao, Erica Walker, Zheren Zhu, Yurui Qian, Mengze Gao, Nan Wang, Yimeng Lin, Lisong Gong, et al.

    Purpose: To push the speed and resolution limit of in vivo quantitative imaging and enable estimation of quantitative tissue parameters of subtle brain structures that were previously difficult to assess. Methods: This study implemented an efficient quantitative imaging approach, 3D‐SPI MRF, on the NexGen 7T scanner equipped with a high‐performance head‐only gradient and 96‐channel receiver array. To address challenges associated with performing rapid mesoscale MRF on this system, acquisition and reconstruction mitigation methods were developed and incorporated into the MRF framework, including: (i) flip‐angle‐aware dictionary fitting to account for both B 1 + inhomogeneity and voxel‐specific RF frequency response, (ii) gradient imperfection corrections via Skope measurements that incorporates a new per‐TR trajectory rewinder compensation, (iii) incorporation of rapid B 1 + and B 0 mappings into the MRF sequence, and (iv) high‐temporal motion navigation. Results: Whole‐brain T 1 and T 2 maps were obtained at 560‐μm isotropic resolution within 4 min, where ablation studies demonstrated the necessity of the various mitigation methods implemented in removing bias and artifacts. For comparison, MRF data were acquired using current state‐of‐the‐art method but limited to typical whole‐body gradient specifications to demonstrate that the proposed developments resulted in ∼3× shorter scan time while producing more accurate parameter maps. Data were also acquired at ∼3.8× smaller voxel size, 360‐μm isotropic, using the developed technique, to achieve mesoscale multi‐parameter quantitative mapping in vivo. Conclusion: Tailored 3D MRF acquisition and reconstruction were developed to enable fast and accurate T 1 and T 2 mapping across the whole‐brain at mesoscale resolution on the NexGen 7T scanner.


  • Open Access

    Reassessment of peripheral nerve stimulation thresholds for the Impulse model‐optimized asymmetric head gradient coil

    by David A. Feinberg, Samantha J. Ma, Erica Walker, Alexander J. S. Beckett, Dominik Rattenbacher, Elmar Rummert, Peter Dietz, Mathias Davids, Nicolas Boulant

    Purpose: Peripheral nerve stimulation (PNS) remains a physiologic limitation to boosting spatiotemporal resolution with more powerful gradients. We investigate discrepancies in previous measurements and model predictions from PNS experienced by volunteers scanned with the investigational “Impulse” gradient coil on the NexGen 7T scanner.Methods: Twenty‐nine volunteers (18 males, mean ± standard deviation age 52.2 ± 17.1 years) underwent PNS characterizations in the scanner. The process was repeated after the subject positions were moved by 2 and 4 cm toward the feet, away from isocenter. These new data were compared with prior experimental data acquired at the factory (32 volunteers, 16 males, mean ± standard deviation age 58.3 ± 13.5 years) and to modeling results initially used to guide the gradient winding pattern.Results: The PNS threshold for the x‐axis (left–right) was significantly below the threshold level predicted by the model used to optimize the wiring pattern and thresholds measured in the factory, whereas there was closer agreement for the y‐axis (anterior–posterior) and z‐axis (superior–inferior). The x‐axis threshold increased as the subject was moved in the Z‐direction toward the foot end of the magnet, at the expense of gradient nonlinearity distortions. Sensitivity of the threshold for the x‐axis was measured as 20 mT/m per centimeter Z‐offset.Conclusion: The PNS threshold of the x‐axis measured in the scanner was much lower than predicted by the optimization model and as measured at the factory. Our measurements verified that PNS thresholds of asymmetric head gradient coils were sensitive to head position, subject variability, and age. The discrepancy of the PNS prediction model remains to be elucidated.


  • Higher spatial resolution and sensitivity in whole brain functional MRI at 7T using 3D EPI accelerated with variable density CAIPI sampling and temporal random walk

    by Suhyung Park, Alexander Beckett, Suvi Häkkinen, Erica Walker, Samantha J. Ma, Sugil Kim, Hahnsung Kim, David A. Feinberg

    Purpose: To develop an efficient 3D EPI encoding technique for high spatiotemporal resolution functional MRI. Methods: To exploit spatiotemporal fMRI data structure, we introduce a variable density 2D CAIPI sampling in the spatial domain combined with time‐wise extra random encoding in the time domain, thus achieving pseudo‐regular sampling with a regular blip while allowing incoherent sampling in a complementary manner across time. This enabled temporally regularized reconstruction of highly accelerated functional data acquisition. The encoding scheme was then validated against temporally invariant CAIPI encoding by applying to locally confined and whole‐brain around the primary visual cortex, respectively, with increasing the spatial resolutions. Results: For partial brain imaging, our proposed method achieved higher reconstruction accuracy, resulting in a substantial increase of SSIM compared to an alternative method for 0.64 mm‐isotropic resolution. When used for whole brain imaging at 0.56 mm‐isotropic resolution, our method showed a decreased spatial extent of activation and produced high‐quality images for a clear distinction between activated and non‐activated regions around calcarine fissure with high spatial specificity. Conclusion: The proposed 3D EPI encoding scheme, which exploits coherent and incoherent sampling properties, can significantly improve the image quality while providing a good balance between sensitivity and specificity in the activated regions.


  • Top Cited Papers
    Open Access

    Next-generation MRI scanner designed for ultra-high-resolution human brain imaging at 7 Tesla

    by David A. Feinberg, Alexander J. S. Beckett, An T. Vu, Jason Stockmann, Laurentius Huber, Samantha Ma, Sinyeob Ahn, Kawin Setsompop, Xiaozhi Cao, Suhyung Park, et al.

    To increase granularity in human neuroimaging science, we designed and built a next-generation 7 Tesla magnetic resonance imaging scanner to reach ultra-high resolution by implementing several advances in hardware. To improve spatial encoding and increase the image signal-to-noise ratio, we developed a head-only asymmetric gradient coil (200 mT m−1, 900 T m−1s−1) with an additional third layer of windings. We integrated a 128-channel receiver system with 64- and 96-channel receiver coil arrays to boost signal in the cerebral cortex while reducing g-factor noise to enable higher accelerations. A 16-channel transmit system reduced power deposition and improved image uniformity. The scanner routinely performs functional imaging studies at 0.35–0.45 mm isotropic spatial resolution to reveal cortical layer functional activity, achieves high angular resolution in diffusion imaging and reduces acquisition time for both functional and structural imaging.


  • Open Access

    Whole-Cerebrum distortion-free three-dimensional pseudo-Continuous Arterial Spin Labeling at 7T

    by Chenyang Zhao, Xingfeng Shao, Qinyang Shou, Samantha J. Ma, Sayim Gokyar, Christina Graf, Rudolf Stollberger, Danny Jj Wang

    Fulfilling potentials of ultrahigh field for pseudo-Continuous Arterial Spin Labeling (pCASL) has been hampered by B1/B0 inhomogeneities that affect pCASL labeling, background suppression (BS), and the readout sequence. This study aimed to present a whole-cerebrum distortion-free three-dimensional (3D) pCASL sequence at 7T by optimizing pCASL labeling parameters, BS pulses, and an accelerated Turbo-FLASH (TFL) readout. A new set of pCASL labeling parameters (Gave=0.4mT/m, Gratio=14.67) was proposed to avoid interferences in bottom slices while achieving robust labeling efficiency (LE). An OPTIM BS pulse was designed based on the range of B1/B0 inhomogeneities at 7T. A 3D TFL readout with 2D-CAIPIRINHA undersampling (R=2×2) and centric ordering was developed, and the number of segments (Nseg) and flip angle (FA) were varied in simulation to achieve the optimal trade-off between SNR and spatial blurring. In-vivo experiments were performed on 19 subjects. The results showed that the new set of labeling parameters effectively achieved whole-cerebrum coverage by eliminating interferences in bottom slices while maintaining a high LE. The OPTIM BS pulse achieved 33.3% higher perfusion signal in gray matter (GM) than the original BS pulse with a cost of 4.8-fold SAR. Incorporating a moderate FA (8 ° ) and Nseg (2), whole-cerebrum 3D TFL-pCASL imaging was achieved with a 2×2×4 mm 3 resolution without distortion and susceptibility artifacts compared to 3D GRASE-pCASL. In addition, 3D TFL-pCASL showed a good to excellent test-retest repeatability and potential of higher resolution (2 mm isotropic). The proposed technique also significantly improved SNR when compared to the same sequence at 3T and simultaneous multislice TFL-pCASL at 7T. By combining a new set of labeling parameters, OPTIM BS pulse, and accelerated 3D TFL readout, we achieved high resolution pCASL at 7T with whole-cerebrum coverage, detailed perfusion and anatomical information without distortion, and sufficient SNR.

  • Open Access

    Optimization of pseudo‐continuous arterial spin labeling at 7T with parallel transmission B1 shimming

    by Kai Wang, Samantha J. Ma, Xingfeng Shao, Chenyang Zhao, Qinyang Shou, Lirong Yan, Danny J. J. Wang

    Purpose: To optimize pseudo‐continuous arterial spin labeling (pCASL) for 7 T, and to further improve the labeling efficiency with parallel RF transmission transmit B1 () shimming.Methods: pCASL parameters were optimized based on field distributions at 7 T with simulation. To increase labeling efficiency, the amplitude at inflowing arteries was increased with parallel RF transmission shimming. The “indv‐shim” with shimming weights calculated for each individual subject, and the “univ‐shim” with universal weights calculated on a group of 12 subjects, were compared with circular polarized (CP) shim. The optimized pCASL sequences with three shimming modes (indv‐shim, univ‐shim, and CP‐shim) were evaluated in 6 subjects who underwent two repeated scans 24 hours apart, along with a pulsed ASL sequence. Quantitative metrics including mean amplitude, perfusion, and intraclass correlation coefficient were calculated. The optimized 7T pCASL was compared with standard 3T pCASL on 5 subjects, using spatial SNR and temporal SNR.Results: The optimal pCASL parameter set (RF duration/gap = 300/250 us, ) achieved robust perfusion measurement in the presence of inhomogeneities. Both indv‐shim and univ‐shim significantly increased amplitude compared with CP‐shim in simulation and in vivo experiment (P < .01). Compared with CP‐shim, perfusion signal was increased by 9.5% with indv‐shim (P < .05) and by 5.3% with univ‐shim (P = .35). All three pCASL sequences achieved fair to good repeatability (intraclass correlation coefficient ≥ 0.5). Compared with 3T pCASL, the optimized 7T pCASL achieved 78.3% higher spatial SNR and 200% higher temporal SNR.Conclusion: The optimized pCASL achieved robust perfusion imaging at 7 T, while both indv‐shim and univ‐shim further increased labeling efficiency.