Transformer‐based deep learning denoising of single and multi‐delay 3D arterial spin labeling
Open Access
- 17 October 2023
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (2) , 803-818
Abstract
Purpose: To present a Swin Transformer‐based deep learning (DL) model (SwinIR) for denoising single‐delay and multi‐delay 3D arterial spin labeling (ASL) and compare its performance with convolutional neural network (CNN) and other Transformer‐based methods.Methods: SwinIR and CNN‐based spatial denoising models were developed for single‐delay ASL. The models were trained on 66 subjects (119 scans) and tested on 39 subjects (44 scans) from three different vendors. Spatiotemporal denoising models were developed using another dataset (6 subjects, 10 scans) of multi‐delay ASL. A range of input conditions was tested for denoising single and multi‐delay ASL, respectively. The performance was evaluated using similarity metrics, spatial SNR and quantification accuracy of cerebral blood flow (CBF), and arterial transit time (ATT).Results: SwinIR outperformed CNN and other Transformer‐based networks, whereas pseudo‐3D models performed better than 2D models for denoising single‐delay ASL. The similarity metrics and image quality (SNR) improved with more slices in pseudo‐3D models and further improved when using M0 as input, but introduced greater biases for CBF quantification. Pseudo‐3D models with three slices achieved optimal balance between SNR and accuracy, which can be generalized to different vendors. For multi‐delay ASL, spatiotemporal denoising models had better performance than spatial‐only models with reduced biases in fitted CBF and ATT maps.Conclusions: SwinIR provided better performance than CNN and other Transformer‐based methods for denoising both single and multi‐delay 3D ASL data. The proposed model offers flexibility to improve image quality and/or reduce scan time for 3D ASL to facilitate its clinical use.Keywords
All Related Versions
This publication has 27 references indexed in Scilit:
- Deep learningNature, 2015
- Recommended implementation of arterial spin‐labeled perfusion MRI for clinical applications: A consensus of the ISMRM perfusion study group and the European consortium for ASL in dementiaMagnetic Resonance in Medicine, 2014
- Reliability of Three-Dimensional Pseudo-Continuous Arterial Spin Labeling MR Imaging for Measuring Visual Cortex Perfusion on Two 3T ScannersPLOS ONE, 2013
- Arterial spin labeling with simultaneous multi‐slice echo planar imagingMagnetic Resonance in Medicine, 2013
- Reliability of two‐dimensional and three‐dimensional pseudo‐continuous arterial spin labeling perfusion MRI in elderly populations: Comparison with 15o‐water positron emission tomographyJournal of Magnetic Resonance Imaging, 2013
- Quantifying the test–retest reliability of cerebral blood flow measurements in a clinical model of on-going post-surgical pain: A study using pseudo-continuous arterial spin labellingNeuroImage: Clinical, 2013
- Multi-delay multi-parametric arterial spin-labeled perfusion MRI in acute ischemic stroke — Comparison with dynamic susceptibility contrast enhanced perfusion imagingNeuroImage: Clinical, 2013
- Test–retest reliability of arterial spin labeling with common labeling strategiesJournal of Magnetic Resonance Imaging, 2011
- Reduction of errors in ASL cerebral perfusion and arterial transit time maps using image de‐noisingMagnetic Resonance in Medicine, 2010
- A general kinetic model for quantitative perfusion imaging with arterial spin labelingMagnetic Resonance in Medicine, 1998