QSQinyang Shou

Qinyang Shou

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Qinyang Shou has a total of 36 co-authors. Here are the top co-authors by number of shared publications:

  • Danny J. J. Wang

    University of Southern California

    10 shared publications
  • Chenyang Zhao

    Laboratory of FMRI Technology (LOFT), Mark & Mary Stevens Neuroimaging and Informatics Institute, Keck School of Medicine University of Southern California Los Angeles California USA

    7 shared publications
  • Xingfeng Shao

    Laboratory of FMRI Technology (LOFT) Mark & Mary Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California Los Angeles California USA

    6 shared publications
  • Hosung Kim

    Laboratory of Neuro Imaging (LONI) Stevens Neuroimaging and Informatics Institute University of Southern California Los Angeles California USA

    2 shared publications
  • Kay Jann

    Laboratory of FMRI Technology (LOFT), Mark & Mary Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California, Los Angeles, USA

    2 shared publications
  • Megan M. Herting

    Department of Population and Public Health Sciences, University of Southern California, Los Angeles, CA, USA

    2 shared publications

Latest Publications

  • Open Access

    Generative diffusion model enables quantification of calibration‐free arterial spin labeling perfusion magnetic resonance imaging data in an Alzheimer's disease cohort

    by Qinyang Shou, Steven Cen, Nan‐Kuei Chen, John M Ringman, Hosung Kim, Clifford R. Jack, Bret J. Borowski, Matthew L. Senjem, Arvin Arani, Danny J. J. Wang, et al.

    INTRODUCTION: M0 images were missing in Siemens ASL data in Alzheimer's Disease Neuroimaging Initiative (ADNI) dataset, prohibiting cerebral blood flow (CBF) quantification. METHODS: A conditional latent diffusion model was trained and evaluated on in‐house datasets, then applied to the Siemens data in ADNI‐3. Regional CBF differences by Alzheimer's disease (AD) stages, their accuracy for AD classification, and CBF trajectory slopes were compared between generated data (Siemens) and acquired data (General Electric). RESULTS: The diffusion model generated M0 images with high fidelity (SSIM = 0.918 ± 0.023, PSNR = 31.361 ± 2.537) and minimal CBF bias (mean difference is 0.21 ± 1.58 mL/100 g/min). Both generated and acquired CBF showed similar spatial patterns and decreasing trends with AD progression in specific AD‐related regions. Generated CBF also improved accuracy in classifying AD stages compared to qualitative perfusion images. CONCLUSION: This study shows the potential of diffusion models for imputing missing modalities in large‐scale studies exploring the use of ASL as a biomarker of AD. Highlights: Using latent diffusion model, we can generate M0 image from control image in arterial spin labeling (ASL) with high fidelity. The generated M0 can be used for cerebral blood flow (CBF) quantification in Alzheimer's Disease Neuroimaging Initiative dataset. The performance of classification between Alzheimer's disease (AD) patients and cognitive normal people is better when using generated CBF maps than using non‐quantitative perfusion images. ASL CBF decreases with AD progression in key AD‐related brain regions.

  • Open Access

    Assessing cerebral microvascular volumetric with high-resolution 4D cerebral blood volume MRI at 7 T

    by Fanhua Guo, Chenyang Zhao, Qinyang Shou, Ning Jin, Kay Jann, Xingfeng Shao, Danny Jj Wang

    Arterial pulsation is crucial for promoting neurofluid circulation. Most previous studies quantified pulsatility via blood velocity-based indices in large arteries. Here we propose an innovative method to quantify the microvascular volumetric pulsatility index (mvPI) across cortical layers and white matter (WM) using high-resolution four-dimensional (4D) vascular space occupancy (VASO) and arterial spin labeling (ASL) magnetic resonance imaging (MRI) at 7 T with simultaneous pulse recording. We assessed aging-related changes in mvPI in 11 young (28.4 ± 5.8 years) and 12 older (60.2 ± 6.8 years) participants and compared mvPI with large artery pulsatility assessed by 4D-flow MRI. mvPI peaked in the pial surface (0.18 ± 0.04). Deep WM mvPI was significantly higher in older participants (P = 0.006) than young ones. Deep WM mvPI correlated with large artery velocity PI (r = 0.56, P = 0.0099). We performed test–retest scans, non-parametric reliability test and simulations to demonstrate the reproducibility and accuracy of the method. In conclusion, our non-invasive method enables in vivo fine-grained measurement of mvPI, with implications for glymphatic function, aging and neurodegenerative diseases.


  • Open Access

    Diffusion model enables quantitative CBF analysis of Alzheimer’s Disease

    by Qinyang Shou, Steven Cen, Nan-Kuei Chen, John M Ringman, Junhao Wen, Hosung Kim, Danny Jj Wang, Alzheimer’s Disease Neuroimaging Initiative

    Objectives: Cerebral blood flow (CBF) measured by arterial spin labeling (ASL) is a promising biomarker for Alzheimer’s Disease (AD). ASL data from multiple vendors were included in the Alzheimer’s Disease Neuroimaging Initiative (ADNI) dataset. However, the M0 images were missing in Siemens ASL data, prohibiting CBF quantification. Here, we utilized a generative diffusion model to impute the missing M0 and validated generated CBF data with acquired data from GE. Methods: A conditional latent diffusion model was trained to generate the M0 image and validate it on an in-house dataset ( N =55) based on image similarity metrics, accuracy of CBF quantification, and consistency with the physical model. This model was then applied to the ADNI dataset (Siemens: N =211) to impute the missing M0 for CBF calculation. We further compared the imputed data (Siemens) and acquired data (GE) regarding regional CBF differences by AD stages, their classification accuracy for AD prediction, and CBF trajectory slopes estimated by a mixed effect model. Results: The trained diffusion model generated the M0 image with high fidelity (Structural similarity index, SSIM=0.924±0.019; peak signal-to-noise ratio, PSNR=33.348±1.831) and caused minimal bias in CBF values (mean difference in whole brain is 1.07±2.12ml/100g/min). Both generated and acquired CBF data showed similar differentiation patterns by AD stages, similar classification performance, and decreasing slopes with AD progression in specific AD-related regions. Generated CBF data also improved accuracy in classifying AD stages compared to qualitative perfusion data. Interpretation/Conclusion: This study shows the potential of diffusion models for imputing missing modalities for large-scale studies of CBF variation with AD.


  • Open Access

    High Resolution Multi-delay Arterial Spin Labeling with Transformer based Denoising for Pediatric Perfusion MRI

    by Qinyang Shou, Chenyang Zhao, Xingfeng Shao, Megan M Herting, Danny Jj Wang

    Multi-delay arterial spin labeling (MDASL) can quantitatively measure cerebral blood flow (CBF) and arterial transit time (ATT), which is particularly suitable for pediatric perfusion imaging. Here we present a high resolution (iso-2mm) MDASL protocol and performed test-retest scans on 21 typically developing children aged 8 to 17 years. We further proposed a Transformer-based deep learning (DL) model with k-space weighted image average (KWIA) denoised images as reference for training the model. The performance of the model was evaluated by the SNR of perfusion images, as well as the SNR, bias and repeatability of the fitted CBF and ATT maps. The proposed method was compared to several benchmark methods including KWIA, joint denoising and reconstruction with total generalized variation (TGV) regularization, as well as directly applying a pretrained Transformer model on a larger dataset. The results show that the proposed Transformer model with KWIA reference can effectively denoise multi-delay ASL images, not only improving the SNR for perfusion images of each delay, but also improving the SNR for the fitted CBF and ATT maps. The proposed method also improved test-retest repeatability of whole-brain perfusion measurements. This may facilitate the use of MDASL in neurodevelopmental studies to characterize typical and aberrant brain development.

  • Open Access

    Transformer‐based deep learning denoising of single and multi‐delay 3D arterial spin labeling

    by Qinyang Shou, Chenyang Zhao, Xingfeng Shao, Kay Jann, Hosung Kim, Karl G. Helmer, Hanzhang Lu, Danny J. J. Wang

    Purpose: To present a Swin Transformer‐based deep learning (DL) model (SwinIR) for denoising single‐delay and multi‐delay 3D arterial spin labeling (ASL) and compare its performance with convolutional neural network (CNN) and other Transformer‐based methods.Methods: SwinIR and CNN‐based spatial denoising models were developed for single‐delay ASL. The models were trained on 66 subjects (119 scans) and tested on 39 subjects (44 scans) from three different vendors. Spatiotemporal denoising models were developed using another dataset (6 subjects, 10 scans) of multi‐delay ASL. A range of input conditions was tested for denoising single and multi‐delay ASL, respectively. The performance was evaluated using similarity metrics, spatial SNR and quantification accuracy of cerebral blood flow (CBF), and arterial transit time (ATT).Results: SwinIR outperformed CNN and other Transformer‐based networks, whereas pseudo‐3D models performed better than 2D models for denoising single‐delay ASL. The similarity metrics and image quality (SNR) improved with more slices in pseudo‐3D models and further improved when using M0 as input, but introduced greater biases for CBF quantification. Pseudo‐3D models with three slices achieved optimal balance between SNR and accuracy, which can be generalized to different vendors. For multi‐delay ASL, spatiotemporal denoising models had better performance than spatial‐only models with reduced biases in fitted CBF and ATT maps.Conclusions: SwinIR provided better performance than CNN and other Transformer‐based methods for denoising both single and multi‐delay 3D ASL data. The proposed model offers flexibility to improve image quality and/or reduce scan time for 3D ASL to facilitate its clinical use.


  • Open Access

    Transformer based deep learning denoising of single and multi-delay 3D Arterial Spin Labeling

    by Qinyang Shou, Chenyang Zhao, Xingfeng Shao, Kay Jann, Karl G. Helmer, Hanzhang Lu, Danny Jj Wang

    Purpose To present a Swin Transformer-based deep learning (DL) model for denoising of single-delay and multi-delay 3D arterial spin labeling (ASL) and compare its performance with convolutional neural network (CNN) methods. Methods Swin Transformer and CNN-based spatial denoising models were developed for single-delay ASL. The models were trained on 59 subjects (104 scans) and tested on 44 subjects (57 scans) from 3 different vendors. Spatiotemporal denoising models were developed using another dataset (6 subjects, 10 scans) of multi-delay ASL. A range of input conditions was tested for denoising single and multi-delay ASL respectively. The performance was evaluated using similarity metrics, spatial signal-to-noise ratio (SNR) and quantification accuracy of cerebral blood flow (CBF) and arterial transit time (ATT). Results Swin Transformer outperformed CNN-based networks, whereas pseudo-3D models showed better performance than 2D models for denoising single-delay ASL. The similarity metrics and image quality (SNR) improved with more slices in pseudo-3D models, and further improved when using M0 as input but introduced greater biases for CBF quantification. Pseudo-3D models with 3 slices as input achieved optimal balance between SNR and accuracy, which can be generalized to different vendors. For multi-delay, spatiotemporal denoising models had better performance than spatial-only models with reduced biases in fitted CBF and ATT maps. Conclusions Swin Transformer DL models provided better performance than CNN methods for denoising both single and multi-delay 3D ASL data. The proposed model offers flexibility to improve image quality and/or reduce scan time for 3D ASL to facilitate its clinical use.


  • Open Access

    Whole-Cerebrum distortion-free three-dimensional pseudo-Continuous Arterial Spin Labeling at 7T

    by Chenyang Zhao, Xingfeng Shao, Qinyang Shou, Samantha J. Ma, Sayim Gokyar, Christina Graf, Rudolf Stollberger, Danny Jj Wang

    Fulfilling potentials of ultrahigh field for pseudo-Continuous Arterial Spin Labeling (pCASL) has been hampered by B1/B0 inhomogeneities that affect pCASL labeling, background suppression (BS), and the readout sequence. This study aimed to present a whole-cerebrum distortion-free three-dimensional (3D) pCASL sequence at 7T by optimizing pCASL labeling parameters, BS pulses, and an accelerated Turbo-FLASH (TFL) readout. A new set of pCASL labeling parameters (Gave=0.4mT/m, Gratio=14.67) was proposed to avoid interferences in bottom slices while achieving robust labeling efficiency (LE). An OPTIM BS pulse was designed based on the range of B1/B0 inhomogeneities at 7T. A 3D TFL readout with 2D-CAIPIRINHA undersampling (R=2×2) and centric ordering was developed, and the number of segments (Nseg) and flip angle (FA) were varied in simulation to achieve the optimal trade-off between SNR and spatial blurring. In-vivo experiments were performed on 19 subjects. The results showed that the new set of labeling parameters effectively achieved whole-cerebrum coverage by eliminating interferences in bottom slices while maintaining a high LE. The OPTIM BS pulse achieved 33.3% higher perfusion signal in gray matter (GM) than the original BS pulse with a cost of 4.8-fold SAR. Incorporating a moderate FA (8 ° ) and Nseg (2), whole-cerebrum 3D TFL-pCASL imaging was achieved with a 2×2×4 mm 3 resolution without distortion and susceptibility artifacts compared to 3D GRASE-pCASL. In addition, 3D TFL-pCASL showed a good to excellent test-retest repeatability and potential of higher resolution (2 mm isotropic). The proposed technique also significantly improved SNR when compared to the same sequence at 3T and simultaneous multislice TFL-pCASL at 7T. By combining a new set of labeling parameters, OPTIM BS pulse, and accelerated 3D TFL readout, we achieved high resolution pCASL at 7T with whole-cerebrum coverage, detailed perfusion and anatomical information without distortion, and sufficient SNR.

  • Open Access

    Quantification of blood–brain barrier water exchange and permeability with multidelay diffusion‐weighted pseudo‐continuous arterial spin labeling

    by Xingfeng Shao, Chenyang Zhao, Qinyang Shou, Keith S. St Lawrence, Danny J. J. Wang

    Purpose: To present a pulse sequence and mathematical models for quantification of blood–brain barrier water exchange and permeability.Methods: Motion‐compensated diffusion‐weighted (MCDW) gradient‐and‐spin echo (GRASE) pseudo‐continuous arterial spin labeling (pCASL) sequence was proposed to acquire intravascular/extravascular perfusion signals from five postlabeling delays (PLDs, 1590–2790 ms). Experiments were performed on 11 healthy subjects at 3 T. A comprehensive set of perfusion and permeability parameters including cerebral blood flow (CBF), capillary transit time (τc), and water exchange rate (kw) were quantified, and permeability surface area product (PSw), total extraction fraction (Ew), and capillary volume (Vc) were derived simultaneously by a three‐compartment single‐pass approximation (SPA) model on group‐averaged data. With information (i.e., Vc and τc) obtained from three‐compartment SPA modeling, a simplified linear regression of logarithm (LRL) approach was proposed for individual kw quantification, and Ew and PSw can be estimated from long PLD (2490/2790 ms) signals. MCDW‐pCASL was compared with a previously developed diffusion‐prepared (DP) pCASL sequence, which calculates kw by a two‐compartment SPA model from PLD = 1800 ms signals, to evaluate the improvements.Results: Using three‐compartment SPA modeling, group‐averaged CBF = 51.5/36.8 ml/100 g/min, kw = 126.3/106.7 min−1, PSw = 151.6/93.8 ml/100 g/min, Ew = 94.7/92.2%, τc = 1409.2/1431.8 ms, and Vc = 1.2/0.9 ml/100 g in gray/white matter, respectively. Temporal SNR of MCDW‐pCASL perfusion signals increased 3‐fold, and individual kw maps calculated by the LRL method achieved higher spatial resolution (3.5 mm3 isotropic) as compared with DP pCASL (3.5 × 3.5 × 8 mm3).Conclusion: MCDW‐pCASL allows visualization of intravascular/extravascular ASL signals across multiple PLDs. The three‐compartment SPA model provides a comprehensive measurement of blood–brain barrier water dynamics from group‐averaged data, and a simplified LRL method was proposed for individual kw quantification.


  • Open Access

    Optimization of pseudo‐continuous arterial spin labeling at 7T with parallel transmission B1 shimming

    by Kai Wang, Samantha J. Ma, Xingfeng Shao, Chenyang Zhao, Qinyang Shou, Lirong Yan, Danny J. J. Wang

    Purpose: To optimize pseudo‐continuous arterial spin labeling (pCASL) for 7 T, and to further improve the labeling efficiency with parallel RF transmission transmit B1 () shimming.Methods: pCASL parameters were optimized based on field distributions at 7 T with simulation. To increase labeling efficiency, the amplitude at inflowing arteries was increased with parallel RF transmission shimming. The “indv‐shim” with shimming weights calculated for each individual subject, and the “univ‐shim” with universal weights calculated on a group of 12 subjects, were compared with circular polarized (CP) shim. The optimized pCASL sequences with three shimming modes (indv‐shim, univ‐shim, and CP‐shim) were evaluated in 6 subjects who underwent two repeated scans 24 hours apart, along with a pulsed ASL sequence. Quantitative metrics including mean amplitude, perfusion, and intraclass correlation coefficient were calculated. The optimized 7T pCASL was compared with standard 3T pCASL on 5 subjects, using spatial SNR and temporal SNR.Results: The optimal pCASL parameter set (RF duration/gap = 300/250 us, ) achieved robust perfusion measurement in the presence of inhomogeneities. Both indv‐shim and univ‐shim significantly increased amplitude compared with CP‐shim in simulation and in vivo experiment (P < .01). Compared with CP‐shim, perfusion signal was increased by 9.5% with indv‐shim (P < .05) and by 5.3% with univ‐shim (P = .35). All three pCASL sequences achieved fair to good repeatability (intraclass correlation coefficient ≥ 0.5). Compared with 3T pCASL, the optimized 7T pCASL achieved 78.3% higher spatial SNR and 200% higher temporal SNR.Conclusion: The optimized pCASL achieved robust perfusion imaging at 7 T, while both indv‐shim and univ‐shim further increased labeling efficiency.