Peripheral quantitative computed tomography is a valid imaging technique for tracking changes in skeletal muscle cross‐sectional area
Open Access
- 26 April 2024
- journal article
- research article
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 44 (5) , 407-414
Abstract
Peripheral quantitative computed tomography (pQCT) has recently expanded to quantifying skeletal muscle, however its validity to determine muscle cross‐sectional area (mCSA) compared to magnetic resonance imaging (MRI) is unknown. Eleven male participants (age: 22 ± 3 y) underwent pQCT and MRI dual‐leg mid‐thigh imaging before (PRE) and after (POST) 6 weeks of resistance training for quantification of mid‐thigh mCSA and change in mCSA. mCSA agreement at both time points and absolute change in mCSA across time was assessed using Bland‐Altman plots for mean bias and 95% limits of agreement (LOA), as well as Lin's concordance correlation coefficients (CCC). Both pQCT and MRI mCSA increased following 6 weeks of resistance training (∆mCSApQCT: 6.7 ± 5.4 cm2, p < 0.001; ∆mCSAMRI: 6.0 ± 6.4 cm2, p < 0.001). Importantly, the change in mCSA was not different between methods (p = 0.39). Bland‐Altman analysis revealed a small mean bias (1.10 cm2, LOA: −6.09, 8.29 cm2) where pQCT tended to overestimate mCSA relative to MRI when comparing images at a single time point. Concordance between pQCT and MRI mCSA at PRE and POST was excellent yielding a CCC of 0.982. For detecting changes in mCSA, Bland‐Altman analysis revealed excellent agreement between pQCT and MRI (mean bias: −0.73 cm2, LOA: −8.37, 6.91 cm2). Finally, there was excellent concordance between pQCT and MRI mCSA change scores (CCC = 0.779). Relative to MRI, pQCT imaging is a valid technique for measuring both mid‐thigh mCSA at a single time point and mCSA changes following a resistance training intervention.Keywords
This publication has 24 references indexed in Scilit:
- Ribosome biogenesis and degradation regulate translational capacity during muscle disuse and reloadingJournal of Cachexia, Sarcopenia and Muscle, 2020
- A Comparison of Peripheral Imaging Technologies for Bone and Muscle Quantification: A Review of Segmentation TechniquesJournal of Clinical Densitometry, 2020
- Skeletal muscle ceramides and relationship with insulin sensitivity after 2 weeks of simulated sedentary behaviour and recovery in healthy older adultsThe Journal of Physiology, 2018
- Panoramic ultrasound: a novel and valid tool for monitoring change in muscle massJournal of Cachexia, Sarcopenia and Muscle, 2017
- Muscle analysis using pQCT, DXA and MRIEuropean Journal of Radiology, 2016
- Multiplicative intrinsic component optimization (MICO) for MRI bias field estimation and tissue segmentationMagnetic Resonance Imaging, 2014
- Effects of filtering methods on muscle and fat cross-sectional area measurement by pQCT: a technical notePhysiological Measurement, 2011
- Contraindications to magnetic resonance imagingHeart, 2008
- Clinical evaluation of a high-resolution new peripheral quantitative computerized tomography (pQCT) scanner for the bone densitometry at the lower limbsPhysics in Medicine & Biology, 1998
- Noninvasive assessment of bone mineral and structure: State of the artJournal of Bone and Mineral Research, 1996