Automatic Sclerosant Injection Technique of Mechanochemical Ablation with ClariVein Using a Syringe Pump for the Treatment of Varicose Veins
Open Access
- 30 September 2020
- journal article
- research article
- Published by The Korean Society for Vascular Surgery in Vascular Specialist International
- Vol. 36 (3) , 198-200
Abstract
Mechanochemical ablation (MOCA) is a non-thermal, non-tumescent technique for the treatment of incompetent saphenous vein. It is sometimes difficult to maintain consistency when simultaneously implementing wire rotation, sclerosant injection, and wire pullback. Here, we report a simple technique for achieving constant injection during MOCA with the help of a syringe pump; thus, the operator can focus on wire pullback only with convenience and consistency.Keywords
This publication has 6 references indexed in Scilit:
- A multi-centre randomised controlled trial comparing radiofrequency and mechanical occlusion chemically assisted ablation of varicose veins – Final results of the Venefit versus Clarivein for varicose veins trialPhlebology: The Journal of Venous Disease, 2016
- Retrograde Inversion Stripping as a Complication of the Clarivein® Mechanochemical Venous Ablation ProcedureThe Annals of The Royal College of Surgeons of England, 2015
- European guidelines for sclerotherapy in chronic venous disordersPhlebology: The Journal of Venous Disease, 2013
- ClariVein Mechanochemical AblationVascular and Endovascular Surgery, 2013
- 2nd European Consensus Meeting on Foam Sclerotherapy 2006, Tegernsee, Germany.2008
- Duplex ultrasound and efficacy criteria in foam sclerotherapy from the 2ndEuropean Consensus Meeting on Foam Sclerotherapy 2006, Tegernsee, GermanyVasa, 2008