Insoo Park
Research Subjects
Insoo Park has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Sujin Park
Charm Vascular Clinic, Seoul, Republic of Korea
2 shared publicationsDaehwan Kim
Charm Vein Center, Gwanak-gu, Seoul, Republic of Korea
1 shared publication- Daehwan Kim
Bioengineering, UC Berkeley, Berkeley, CA, 94720, USA
1 shared publication - Dogeun Kim
ENGAIN Co. Ltd., 700, Daewangpangyo-ro, Bundang-gu, Seongnam 13488, Gyeonggi-do, Korea
1 shared publication - Habeen Park
ENGAIN Co. Ltd., 700, Daewangpangyo-ro, Bundang-gu, Seongnam 13488, Gyeonggi-do, Korea
1 shared publication - Jae-Won Seo
ENGAIN Co. Ltd., 700, Daewangpangyo-ro, Bundang-gu, Seongnam 13488, Gyeonggi-do, Korea
1 shared publication
Latest Publications
- 8 July 2026
- Published by SAGE Publications in Phlebology: The Journal of Venous Disease
Which modality for which vein? A narrative review of strategic modality selection for chronic venous disease treatment
Introduction: Management of chronic venous disease (CVD) has shifted from high ligation and stripping (HL/S) to multiple endovenous options, yet no single technique is optimal for all anatomical patterns or patient profiles. This narrative review aimed to summarize current evidence and guideline recommendations and outline an anatomy-oriented framework for modality selection in daily practice. Methods: A non-systematic search of MEDLINE and current guidelines from the European Society for Vascular Surgery and the Society for Vascular Surgery/American Venous Forum/American Vein and Lymphatic Society was performed, focusing on comparative trials, long-term series and key reviews of HL/S, endovenous thermal techniques (TT), cyanoacrylate closure (CAC), mechanochemical ablation (MOCA) and ultrasound-guided foam sclerotherapy (UGFS). Evidence was synthesized descriptively with attention to anatomical indications, efficacy and complications. Results: HL/S remains valuable for markedly dilated, aneurysmal or tortuous trunks, epifascial segments and junctional disease with thrombus or unfavorable anatomy, and may provide durable occlusion in very large veins. TT is the best-studied modality, achieving high occlusion rates, rapid recovery and broad applicability across typical truncal diameters, but efficacy and skin-related events are problematic in superficial or extremely large veins. CAC and MOCA, as non-thermal non-tumescent options, offer excellent periprocedural comfort and avoid thermal nerve injury, making them attractive for below-the-knee segments; however, durability appears less robust in large-diameter or long trunks and both incur higher device-related costs. CAC is uniquely associated with phlebitis-like abnormal reaction or hypersensitivity. UGFS remains a versatile option for complex recurrent varices and neovascularization but is less suitable as a first-line treatment for truncal reflux. Conclusions: No single “gold-standard” modality suffices for all CVD presentations. An anatomy- and patient-centered strategy that deliberately deploys all available modalities or hybrid combinations based on vein diameter, depth, length and patient factors is essential to optimize occlusion and minimize complications in daily practice.
- 8 July 2026
- Published by SAGE Publications in Phlebology: The Journal of Venous Disease
Which modality for which vein? A narrative review of strategic modality selection for chronic venous disease treatment
Introduction: Management of chronic venous disease (CVD) has shifted from high ligation and stripping (HL/S) to multiple endovenous options, yet no single technique is optimal for all anatomical patterns or patient profiles. This narrative review aimed to summarize current evidence and guideline recommendations and outline an anatomy-oriented framework for modality selection in daily practice. Methods: A non-systematic search of MEDLINE and current guidelines from the European Society for Vascular Surgery and the Society for Vascular Surgery/American Venous Forum/American Vein and Lymphatic Society was performed, focusing on comparative trials, long-term series and key reviews of HL/S, endovenous thermal techniques (TT), cyanoacrylate closure (CAC), mechanochemical ablation (MOCA) and ultrasound-guided foam sclerotherapy (UGFS). Evidence was synthesized descriptively with attention to anatomical indications, efficacy and complications. Results: HL/S remains valuable for markedly dilated, aneurysmal or tortuous trunks, epifascial segments and junctional disease with thrombus or unfavorable anatomy, and may provide durable occlusion in very large veins. TT is the best-studied modality, achieving high occlusion rates, rapid recovery and broad applicability across typical truncal diameters, but efficacy and skin-related events are problematic in superficial or extremely large veins. CAC and MOCA, as non-thermal non-tumescent options, offer excellent periprocedural comfort and avoid thermal nerve injury, making them attractive for below-the-knee segments; however, durability appears less robust in large-diameter or long trunks and both incur higher device-related costs. CAC is uniquely associated with phlebitis-like abnormal reaction or hypersensitivity. UGFS remains a versatile option for complex recurrent varices and neovascularization but is less suitable as a first-line treatment for truncal reflux. Conclusions: No single “gold-standard” modality suffices for all CVD presentations. An anatomy- and patient-centered strategy that deliberately deploys all available modalities or hybrid combinations based on vein diameter, depth, length and patient factors is essential to optimize occlusion and minimize complications in daily practice.
- Open Access
- 23 October 2025
- Published by Elsevier in Journal of Vascular Surgery: Venous and Lymphatic Disorders
- Vol. 14 (1) , 102345
One-year outcomes of mechanochemical ablation of incompetent saphenous veins using the Flebogrif device
- 23 October 2025
- Published by Elsevier in Journal of Vascular Surgery: Venous and Lymphatic Disorders
- Vol. 14 (1) , 102345
Open AccessOne-year outcomes of mechanochemical ablation of incompetent saphenous veins using the Flebogrif device
- Open Access
- 31 December 2024
- Published by The Korean Society for Phlebology in Annals of Phlebology
- Vol. 22 (2) , 77-81
Early Outcomes of Flebogrif®, a Mechanochemical Ablation Technique, for Treating Chronic Venous Disorders
Insoo Park, M.D., Sujin Park, M.D.. Ann Phlebology 2024;22:77-81. https://doi.org/10.37923/phle.2024.22.2.77
- 31 December 2024
- Published by The Korean Society for Phlebology in Annals of Phlebology
- Vol. 22 (2) , 77-81
Open AccessEarly Outcomes of Flebogrif®, a Mechanochemical Ablation Technique, for Treating Chronic Venous Disorders
Insoo Park, M.D., Sujin Park, M.D.. Ann Phlebology 2024;22:77-81. https://doi.org/10.37923/phle.2024.22.2.77
- Open Access
- 4 March 2024
- Published by The Korean Society for Vascular Surgery in Vascular Specialist International
- Vol. 40 (1) , 6
Ethical Considerations and Adverse Events in Cyanoacrylate Embolization for Non-Saphenous Veins: A Case Report
Insoo Park. Vasc Specialist Int 2024;40:. https://doi.org/10.5758/vsi.230102
- 4 March 2024
- Published by The Korean Society for Vascular Surgery in Vascular Specialist International
- Vol. 40 (1) , 6
Open AccessEthical Considerations and Adverse Events in Cyanoacrylate Embolization for Non-Saphenous Veins: A Case Report
Insoo Park. Vasc Specialist Int 2024;40:. https://doi.org/10.5758/vsi.230102
- Open Access
In Vivo Animal Study of a Highly Viscous N-butyl Cyanoacrylate Medical Adhesive for Intravenous Embolization
N-butyl cyanoacrylate (NBCA) is a liquid monomer that undergoes an exothermic polymerization reaction to form a solid upon initiation with hydroxyl anions. Recently, EGpresto, a highly viscous NBCA-based adhesive, has been developed for vascular-occlusion purposes. In this study, we investigated the heat of polymerization of EGpresto and compared the results with those of a low-viscosity NBCA glue. Results show that EGpresto exhibited a lower heat of polymerization (64 ± 7 °C vs. 34 ± 1 °C). This was due to its high viscosity, which resulted in a delayed polymerization time. To investigate the efficacy and safety of EGpresto for intravenous embolization, a 14 d in vivo animal test was conducted using three pigs. Five cc of EGpresto was injected into the epigastric vein of each animal. Complete postoperative vein occlusion was confirmed at 7 and 14 d by ultrasonographic visualization. After the animals were sacrificed, the operated and unoperated veins were exposed, and the injected adhesive was found without migration. During the histology, the injected adhesive was not found in the inner or outer vein walls, and the immune reactions seemed to be the only foreign-body reaction, showing that EGpresto is a non-toxic and safe intravascular embolic agent.
Open AccessIn Vivo Animal Study of a Highly Viscous N-butyl Cyanoacrylate Medical Adhesive for Intravenous Embolization
N-butyl cyanoacrylate (NBCA) is a liquid monomer that undergoes an exothermic polymerization reaction to form a solid upon initiation with hydroxyl anions. Recently, EGpresto, a highly viscous NBCA-based adhesive, has been developed for vascular-occlusion purposes. In this study, we investigated the heat of polymerization of EGpresto and compared the results with those of a low-viscosity NBCA glue. Results show that EGpresto exhibited a lower heat of polymerization (64 ± 7 °C vs. 34 ± 1 °C). This was due to its high viscosity, which resulted in a delayed polymerization time. To investigate the efficacy and safety of EGpresto for intravenous embolization, a 14 d in vivo animal test was conducted using three pigs. Five cc of EGpresto was injected into the epigastric vein of each animal. Complete postoperative vein occlusion was confirmed at 7 and 14 d by ultrasonographic visualization. After the animals were sacrificed, the operated and unoperated veins were exposed, and the injected adhesive was found without migration. During the histology, the injected adhesive was not found in the inner or outer vein walls, and the immune reactions seemed to be the only foreign-body reaction, showing that EGpresto is a non-toxic and safe intravascular embolic agent.
- 1 February 2021
- Published by Elsevier in Annals of Vascular Surgery
- Vol. 71, 534.e17-534.e21
Human Saphenous Vein Histopathology 2 Years After Cyanoacrylate Closure Using the VenaSeal™ System
- 1 February 2021
- Published by Elsevier in Annals of Vascular Surgery
- Vol. 71, 534.e17-534.e21
Human Saphenous Vein Histopathology 2 Years After Cyanoacrylate Closure Using the VenaSeal™ System
- Open Access
- 31 December 2020
- Published by The Korean Society for Vascular Surgery in Vascular Specialist International
- Vol. 36 (4) , 273-274
Using a Syringe Pump during Mechanochemical Ablation Is Not Mandatory, but It Is Easy to Control
- 31 December 2020
- Published by The Korean Society for Vascular Surgery in Vascular Specialist International
- Vol. 36 (4) , 273-274
Open AccessUsing a Syringe Pump during Mechanochemical Ablation Is Not Mandatory, but It Is Easy to Control
- Open Access
- 30 September 2020
- Published by The Korean Society for Vascular Surgery in Vascular Specialist International
- Vol. 36 (3) , 198-200
Automatic Sclerosant Injection Technique of Mechanochemical Ablation with ClariVein Using a Syringe Pump for the Treatment of Varicose Veins
Mechanochemical ablation (MOCA) is a non-thermal, non-tumescent technique for the treatment of incompetent saphenous vein. It is sometimes difficult to maintain consistency when simultaneously implementing wire rotation, sclerosant injection, and wire pullback. Here, we report a simple technique for achieving constant injection during MOCA with the help of a syringe pump; thus, the operator can focus on wire pullback only with convenience and consistency.
- 30 September 2020
- Published by The Korean Society for Vascular Surgery in Vascular Specialist International
- Vol. 36 (3) , 198-200
Open AccessAutomatic Sclerosant Injection Technique of Mechanochemical Ablation with ClariVein Using a Syringe Pump for the Treatment of Varicose Veins
Mechanochemical ablation (MOCA) is a non-thermal, non-tumescent technique for the treatment of incompetent saphenous vein. It is sometimes difficult to maintain consistency when simultaneously implementing wire rotation, sclerosant injection, and wire pullback. Here, we report a simple technique for achieving constant injection during MOCA with the help of a syringe pump; thus, the operator can focus on wire pullback only with convenience and consistency.
- 1 July 2020
- Published by Elsevier in Journal of Vascular Surgery: Venous and Lymphatic Disorders
- Vol. 8 (4) , 697-698
Shall we focus on the additives of glue for phlebitis-like abnormal reaction?
- 1 July 2020
- Published by Elsevier in Journal of Vascular Surgery: Venous and Lymphatic Disorders
- Vol. 8 (4) , 697-698
Shall we focus on the additives of glue for phlebitis-like abnormal reaction?
- Open Access
- 3 October 2019
- Published by SAGE Publications in Vascular and Endovascular Surgery
- Vol. 54 (1) , 47-50
Correlation Between the Immediate Remnant Stump Length and Vein Diameter After Cyanoacrylate Closure Using the VenaSeal System During Treatment of an Incompetent Great Saphenous Vein
Cyanoacrylate glue is injected for incompetent great saphenous vein (GSV) treatment 5 cm distal to the saphenofemoral junction (SFJ). Although a few reports have investigated the postprocedural remnant stump length, none have focused on the factors affecting glue extension length and the consequent remnant stump length. Seventy-nine patients undergoing cyanoacrylate closure using the VenaSeal system at our clinic between August 2018 and November 2018 were investigated. The GSV diameter was measured just before treatment in the supine position 3 cm distal to the SFJ. Cyanoacrylate glue was injected 5 cm distal to the SFJ. The mean glue extension length was 1.13 ± 1.12 cm. The GSV diameter and glue extension length exhibited a significant inversely proportional relationship (P < .001). More specifically, patients with a GSV diameter ≥0.7 cm had a longer remnant stump length than those with a smaller GSV diameter (P < .001). An increased GSV diameter is likely associated with a decreased glue extension length and, consequently, a longer remnant stump.
- 3 October 2019
- Published by SAGE Publications in Vascular and Endovascular Surgery
- Vol. 54 (1) , 47-50
Open AccessCorrelation Between the Immediate Remnant Stump Length and Vein Diameter After Cyanoacrylate Closure Using the VenaSeal System During Treatment of an Incompetent Great Saphenous Vein
Cyanoacrylate glue is injected for incompetent great saphenous vein (GSV) treatment 5 cm distal to the saphenofemoral junction (SFJ). Although a few reports have investigated the postprocedural remnant stump length, none have focused on the factors affecting glue extension length and the consequent remnant stump length. Seventy-nine patients undergoing cyanoacrylate closure using the VenaSeal system at our clinic between August 2018 and November 2018 were investigated. The GSV diameter was measured just before treatment in the supine position 3 cm distal to the SFJ. Cyanoacrylate glue was injected 5 cm distal to the SFJ. The mean glue extension length was 1.13 ± 1.12 cm. The GSV diameter and glue extension length exhibited a significant inversely proportional relationship (P < .001). More specifically, patients with a GSV diameter ≥0.7 cm had a longer remnant stump length than those with a smaller GSV diameter (P < .001). An increased GSV diameter is likely associated with a decreased glue extension length and, consequently, a longer remnant stump.