Dynamic Performance Evaluation of N-channel MOSFET under Gamma Irradiation
Open Access
- 1 April 2024
- journal article
- research article
- Published by Egyptian Knowledge Bank in Arab Journal of Nuclear Sciences and Applications
- Vol. 57 (2) , 63-76
Abstract
Experimental studies for two groups n-channel MOSFET are conducted. Each group, which have two devices from the same type, is exposed to dosages of gamma-ray ionizing radiation. The main objective of this study is to discuss the dynamic performance of these types under ionizing radiation for purpose of usage as a radiation dosimeter. Novelty of this study arisen from that the dynamic parameters such as threshold voltage, rise and fall times, different transconducatances and capacitances between device terminals are investigated. Because of gamma-ray irradiation, the surface and interface charges are arisen into MOSFET region. The threshold voltage is dependent on the MOSFET parameters, as it depends reversely on the oxide capacitance. From the obtained results, the channel width and length play an important role for determining all the dynamic parameters. One can notice that the majority of capacitances values are decreased. Consequently, the threshold voltage is decreased with the increase of radiation dose. From outcomes, the different transconductance values have different comportment according to the channel width and length into these adjacent regions. The devices under study are considered as a candidate to be a dosimeter for gamma-ray radiation.Keywords
This publication has 23 references indexed in Scilit:
- A Study of the Performance of an N-Channel MOSFET Under Gamma Radiation as a DosimeterJournal of Electronic Materials, 2020
- Study the Behavior of Carbon Nanotube Networks for Flow-Encoded DataJournal of Electronic Materials, 2019
- Effect of gamma ray absorbed dose on the FET transistor parametersResults in Physics, 2016
- Contribution of fixed oxide traps to sensitivity of pMOS dosimeters during gamma ray irradiation and annealing at room and elevated temperatureSensors and Actuators A: Physical, 2012
- Thermal drift reduction with multiple bias current for MOSFET dosimetersPhysics in Medicine & Biology, 2011
- Evaluation of a low-cost commercial mosfet as radiation dosimeterSensors and Actuators A: Physical, 2006
- Effect of 30 Mev Li 3+ ion and 8 MeV electron irradiation on n-channel MOSFETsRadiation Effects and Defects in Solids, 2002
- Electronic dosimeters based on solid state detectorsNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2001
- p MOS transistors for dosimetric applicationElectronics Letters, 1993
- Linearity of p MOS radiation dosimeters operated at zero biasElectronics Letters, 1985