On-line signal quality estimation of multichannel surface electromyograms
Authors:
- 1 June 2005
- journal article
- research article
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 43 (3) , 357-364
Abstract
When multichannel surface-electromyography (MCSEMG) systems are used, there is a risk of recording low-quality signals. Such signals can be confusing for analysis and interpretation and can be caused by power-line interference, motion artifacts or poor electrode-skin contact. Usually, the electrode-skin impedance is measured to estimate the quality of the contact between the electrodes and the skin. However, this is not always practical, and the contact can change over short time-scales. A fast method is described to estimate the quality of individual signals of monopolar MCSEMG recordings based on volume conduction of myo-electric signals. The characteristics of the signals were described using two descriptor variables. Outliers (extreme data points) were detected in the two-dimensional distributions of the descriptor variables using a non-parametric technique, and the quality of the signals was estimated by their outlier probabilities. The method's performance was evaluated using 1 s long signals visually classified as very poor (G1), poor (G2) or good quality (G3). Recordings from different subjects, contraction levels and muscles were used. An optimum threshold at 0.05 outlier probability was proposed and resulted in classification accuracies of 100% and >70% for G1 and G2 signals, respectively, whereas <5% of the G3 signals were classified as poor. In conclusion, the proposed method estimated MCSEMG signal quality with high accuracy, compared with visual assessment, and is suitable for on-line implementation. The method could be applied to other multichannel sensor systems, with an arbitrary number of descriptor variables, when their distributions can be assumed to lie within a certain range.Keywords
This publication has 22 references indexed in Scilit:
- Inhomogeneities in muscle activation reveal motor unit recruitmentJournal of Electromyography and Kinesiology, 2005
- Simultaneous estimation of muscle fibre conduction velocity and muscle fibre orientation using 2D multichannel surface electromyogramMedical & Biological Engineering & Computing, 2005
- Changes in muscle fiber conduction velocity indicate recruitment of distinct motor unit populationsJournal of Applied Physiology, 2003
- Evolution in impedance at the electrode-skin interface of two types of surface EMG electrodes during long-term recordingsJournal of Electromyography and Kinesiology, 2003
- A Fast Algorithm for the Minimum Covariance Determinant EstimatorTechnometrics, 1999
- Robust bivariate boxplots and multiple outlier detectionComputational Statistics & Data Analysis, 1998
- The origin of skin-stretch-caused motion artifacts under electrodesPhysiological Measurement, 1996
- Fast Very Robust Methods for the Detection of Multiple OutliersJournal of the American Statistical Association, 1994
- Temporal changes in electrode impedance while recording the electrocardiogram with “Dry” electrodesAnnals of Biomedical Engineering, 1973
- Multivariate Normal PlottingJournal of the Royal Statistical Society Series C: Applied Statistics, 1968