Simultaneous determination of copper, mercury and zinc in water with a tailored fluorescent bipyridine ligand entrapped in silica sol-gel
- 9 October 2010
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 398 (7-8) , 3127-3138
Abstract
A novel fluorescent ligand, (4-[(E)-2-(4′-methyl-2,2′-bipyridin-4-yl)vinyl]phenol) (abbreviated BSOH), has been designed and prepared for simultaneous determination of heavy metals in water. Its photophysical and photochemical properties in the absence and in the presence of Cd(II), Cu(II), Hg(II), Ni(II) and Zn(II) were determined, and the respective complexation constants (7.4 × 103–2.8 × 108 l mol−1) and stoichiometries were extracted thereof. The Stern–Volmer emission intensity and lifetime plots indicate an efficient static quenching of the indicator dye with the heavy metals. The BSOH fluorescent reagent has been successfully immobilised in a silica sol-gel matrix for automation of the analytical method, and the sensing phase demonstrated a reversible response to Cu(II), Hg(II) and Zn(II) but not to Cd(II) and Ni(II). Characterisation of the sensor showed that its response to those heavy metals is linear in the 2.5 to 50 μmol l−1 range, with a response time (t 90) on the order of 100 min, providing detection limits of 9.0 × 10−7, 4.7 × 10−7 and 2.9 × 10−7 mol l −1 for Zn(II), Cu(II) and Hg(II), respectively. Due to the stability of the immobilised ligand, which presented no leaching from the sol-gel matrix, the simultaneous determination of the three cations in water was feasible by employing multivariate calibration techniques coupled to fluorescence quenching measurements. The sensor was validated with recovery tests by addition of Cu(II) and Hg(II) ions to spring waters, providing results with standard errors lower than 4.1 μmol l −1.Keywords
This publication has 39 references indexed in Scilit:
- Sol–gel matrix modified microstructured optical fibre towards a fluoride sensitive optical probeOptics Communications, 2009
- Optical sensors and biosensors based on sol–gel filmsTalanta, 2007
- Simultaneous determination of copper, lead and cadmium by cathodic adsorptive stripping voltammetry using artificial neural networkAnalytica Chimica Acta, 2006
- Quantification of Ternary Mixtures of Heavy Metal Cations from Metallochromic Absorbance Spectra Using Neural Network InversionAnalytical Chemistry, 2004
- Chemically selective membrane optode for Cr(VI) determination in aqueous samplesAnalytica Chimica Acta, 2004
- Development of a new bulk optode membrane for the determination of mercury(II)Analytica Chimica Acta, 2000
- Quimiometria I: calibração multivariada, um tutorialQuímica Nova, 1999
- Heavy metal ions detection in solution, in sol–gel and with grafted porphyrin monolayersJournal of Photochemistry and Photobiology A: Chemistry, 1999
- Nafion-based optode for the detection of metal ions in flow analysisAnalytica Chimica Acta, 1996
- Fluorimetric determination of mercury with a water-soluble porphyrin and porphyrin-doped sol-gel filmsAnalytica Chimica Acta, 1995