Quantitative assessment of manual and robotic microcannulation for eye surgery using new eye model
- 16 April 2014
- journal article
- research article
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 11 (2) , 210-217
Abstract
Background Microcannulation, a surgical procedure for the eye that requires drug injection into a 60–90 µm retinal vein, is difficult to perform manually. Robotic assistance has been proposed; however, its effectiveness in comparison to manual operation has not been quantified. Methods An eye model has been developed to quantify the performance of manual and robotic microcannulation. The eye model, which is implemented with a force sensor and microchannels, also simulates the mechanical constraints of the instrument's movement. Ten subjects performed microcannulation using the model, with and without robotic assistance. Results The results showed that the robotic assistance was useful for motion stability when the drug was injected, whereas its positioning accuracy offered no advantage. Conclusions An eye model was used to quantitatively assess the robotic microcannulation performance in comparison to manual operation. This approach could be valid for a better evaluation of surgical robotic assistance. Copyright © 2014 John Wiley & Sons, Ltd.Keywords
Funding Information
- Japan Society for the Promotion of Science (23226006)
- Global Center of Excellence for Mechanical Systems Innovation (GMSI) at the University of Tokyo
This publication has 11 references indexed in Scilit:
- Impact of Robotic Assistance on Precision of Vitreoretinal Surgical ProceduresPLOS ONE, 2013
- Design and analysis of 6 DOF handheld micromanipulator2012
- Microsurgical robotic system for vitreoretinal surgeryInternational Journal of Computer Assisted Radiology and Surgery, 2011
- New steady-hand Eye Robot with micro-force sensing for vitreoretinal surgery2010
- A parallel robot to assist vitreoretinal surgeryInternational Journal of Computer Assisted Radiology and Surgery, 2009
- Physiological tremor amplitude during retinal microsurgery2002
- An Active Hand-Held Instrument for Enhanced Microsurgical Accuracy2000
- Toward robot-assisted vascular microsurgery in the retinaGraefe's Archive for Clinical and Experimental Ophthalmology, 1997
- A comparison of the elastic properties of human choroid and scleraExperimental Eye Research, 1988
- In vivo cannulation of retinal vesselsGraefe's Archive for Clinical and Experimental Ophthalmology, 1987