Shinichi Tanaka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shinichi Tanaka has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Mamoru Mitsuishi
Univ. of Tokyo
4 shared publications Naohiko Sugita
The University of Tokyo
4 shared publications- Kanako Harada
Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
3 shared publications Takashi Ueta
The University of Tokyo
3 shared publicationsAkio Morita
Nippon Medical School
2 shared publicationsFumihito Arai
Nagoya University
2 shared publications
Latest Publications
- 1 January 2015
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2015, _1P1-D02_1
1P1-D02 Development of task recognition algorithm for mircosurgical robotic system
- 1 January 2015
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2015, _1P1-D02_1
1P1-D02 Development of task recognition algorithm for mircosurgical robotic system
- 16 April 2014
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 11 (2) , 210-217
Quantitative assessment of manual and robotic microcannulation for eye surgery using new eye model
Background Microcannulation, a surgical procedure for the eye that requires drug injection into a 60–90 µm retinal vein, is difficult to perform manually. Robotic assistance has been proposed; however, its effectiveness in comparison to manual operation has not been quantified. Methods An eye model has been developed to quantify the performance of manual and robotic microcannulation. The eye model, which is implemented with a force sensor and microchannels, also simulates the mechanical constraints of the instrument's movement. Ten subjects performed microcannulation using the model, with and without robotic assistance. Results The results showed that the robotic assistance was useful for motion stability when the drug was injected, whereas its positioning accuracy offered no advantage. Conclusions An eye model was used to quantitatively assess the robotic microcannulation performance in comparison to manual operation. This approach could be valid for a better evaluation of surgical robotic assistance. Copyright © 2014 John Wiley & Sons, Ltd.
- 16 April 2014
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 11 (2) , 210-217
Quantitative assessment of manual and robotic microcannulation for eye surgery using new eye model
Background Microcannulation, a surgical procedure for the eye that requires drug injection into a 60–90 µm retinal vein, is difficult to perform manually. Robotic assistance has been proposed; however, its effectiveness in comparison to manual operation has not been quantified. Methods An eye model has been developed to quantify the performance of manual and robotic microcannulation. The eye model, which is implemented with a force sensor and microchannels, also simulates the mechanical constraints of the instrument's movement. Ten subjects performed microcannulation using the model, with and without robotic assistance. Results The results showed that the robotic assistance was useful for motion stability when the drug was injected, whereas its positioning accuracy offered no advantage. Conclusions An eye model was used to quantitatively assess the robotic microcannulation performance in comparison to manual operation. This approach could be valid for a better evaluation of surgical robotic assistance. Copyright © 2014 John Wiley & Sons, Ltd.
- 1 January 2012
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2012, _2P1-T05_1
2P1-T05 Jerk-Minimized Trajectory Generation for Master-Slave Robotic System(Surgical Robotics and Mechatronics(2))
This paper describes a trajectory generation method for a master-slave surgical robotic system. Because the data from the master system is intermittent due to the limit in master-slave communication rate, interpolation is required to achieve the smooth motion of the slave robot. In particular, real-time interpolation is crucial for surgical systems. To cope with this problem, we propose a new smooth trajectory generation method by minimizing jerk using a quintic B-spline. To ensure the third-order continuity in position, velocity and acceleration, the trajectory of next time segment is generated using several fictive control points. In addition, we impose a minimum jerk constraint to obtain a smooth trajectory. The proposed method was tested and compared with a conventional trajectory generation method. The experimental results show that the proposed method generated a smoother trajectory with fewer jerks, which is sufficient for use in real-time control of the surgical robotic system.
- 1 January 2012
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2012, _2P1-T05_1
2P1-T05 Jerk-Minimized Trajectory Generation for Master-Slave Robotic System(Surgical Robotics and Mechatronics(2))
This paper describes a trajectory generation method for a master-slave surgical robotic system. Because the data from the master system is intermittent due to the limit in master-slave communication rate, interpolation is required to achieve the smooth motion of the slave robot. In particular, real-time interpolation is crucial for surgical systems. To cope with this problem, we propose a new smooth trajectory generation method by minimizing jerk using a quintic B-spline. To ensure the third-order continuity in position, velocity and acceleration, the trajectory of next time segment is generated using several fictive control points. In addition, we impose a minimum jerk constraint to obtain a smooth trajectory. The proposed method was tested and compared with a conventional trajectory generation method. The experimental results show that the proposed method generated a smoother trajectory with fewer jerks, which is sufficient for use in real-time control of the surgical robotic system.
- 1 January 2012
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2012, _2P1-U05_1
2P1-U05 Cartesian control method using visual servoing for surgical robotic system(Surgical Robotics and Mechatronics(2))
Autonomous positioning of surgical robotic forceps is very promising toward high-level assistant function such as automated task. It is the first step toward autonomous surgical systems that can make full use of the robotic system. To achieve high accuracy in positioning, visual servoing technique is utilized in many applications. However, in visual servoing, we cannot control the trajectory of motion in Cartesian space. Undesired behavior of forceps in Cartesian space may make damage to tissue or blood vessels. To cope with the problem, we propose a vision-guided positioning system with z-separated visual servoing. The interaction matrix is decomposed into positioning and approaching components. Approaching velocity is computed on the basis of difference of disparity, and positioning velocity is yielded by reformulated interaction matrix. The experimental results showed that the proposed method can control the trajectory in Cartesian space by adjusting approaching parameter. Furthermore, the needle gripping task is successfully performed. We expect that this method would be used for autonomous surgical system.
- 1 January 2012
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2012, _2P1-U05_1
2P1-U05 Cartesian control method using visual servoing for surgical robotic system(Surgical Robotics and Mechatronics(2))
Autonomous positioning of surgical robotic forceps is very promising toward high-level assistant function such as automated task. It is the first step toward autonomous surgical systems that can make full use of the robotic system. To achieve high accuracy in positioning, visual servoing technique is utilized in many applications. However, in visual servoing, we cannot control the trajectory of motion in Cartesian space. Undesired behavior of forceps in Cartesian space may make damage to tissue or blood vessels. To cope with the problem, we propose a vision-guided positioning system with z-separated visual servoing. The interaction matrix is decomposed into positioning and approaching components. Approaching velocity is computed on the basis of difference of disparity, and positioning velocity is yielded by reformulated interaction matrix. The experimental results showed that the proposed method can control the trajectory in Cartesian space by adjusting approaching parameter. Furthermore, the needle gripping task is successfully performed. We expect that this method would be used for autonomous surgical system.