Abstract
An online detection method for the inter‐turn short‐circuit fault (ISCF) of a dual‐redundancy permanent magnet synchronous motor (DRPMSM) is proposed. First, the electromagnetic relationships in a DRPMSM without mutual inductances are analysed theoretically upon the occurrence of the ISCF. Then, a simulation model of the motor with ISCF is established, and the arithmetic mean for the ratio of the squared amplitude difference between two sets of space voltage vectors to squared frequency is used to identify the faulty winding by the difference between the back electromotive force and impedance of the dual winding. It is shown to be valid even with variations in the load, speed, contact resistance, and number of short‐circuit turns. The simulation and experimental results thus verify the effectiveness of the proposed method.Keywords
Funding Information
- National Natural Science Foundation of China (51377114)
This publication has 26 references indexed in Scilit:
- Detection of Inter-Turn and Dynamic Eccentricity Faults Using Stator Current Frequency Pattern in IPM-Type BLDC MotorsIEEE Transactions on Industrial Electronics, 2015
- Interturn Fault Diagnosis Strategy for Interior Permanent-Magnet Synchronous Motor of Electric Vehicles Based on Digital Signal ProcessorIEEE Transactions on Industrial Electronics, 2015
- Online Interturn Fault Diagnosis of Permanent Magnet Synchronous Machine Using Zero-Sequence ComponentsIEEE Transactions on Power Electronics, 2015
- Nonvolatile Boolean Logic Block Based on Ferroelectric Tunnel MemristorIEEE Transactions on Magnetics, 2014
- Early Detection Technique for Stator Winding Inter-Turn Fault in BLDC Motor Using Input ImpedanceIEEE Transactions on Industry Applications, 2014
- Simple Online Fault Detecting Scheme for Short-Circuited Turn in a PMSM Through Current Harmonic MonitoringIEEE Transactions on Industrial Electronics, 2010
- Fault model and performance evaluation of an inverter-fed permanent magnet synchronous motor under winding shorted turn and inverter switch openIET Electric Power Applications, 2010
- Fractional-Slot Concentrated-Windings Synchronous Permanent Magnet Machines: Opportunities and ChallengesIEEE Transactions on Industrial Electronics, 2009
- Short-Circuit Detection by Means of Empirical Mode Decomposition and Wigner–Ville Distribution for PMSM Running Under Dynamic ConditionIEEE Transactions on Industrial Electronics, 2009
- Condition monitoring and fault detection of wind turbines and related algorithms: A reviewRenewable and Sustainable Energy Reviews, 2009