H2O2 biosensor consisted of hemoglobin-DNA conjugate on nanoporous gold thin film electrode with electrochemical signal enhancement
Open Access
- 3 January 2019
- journal article
- research article
- Published by Springer Nature in Nano Convergence
- Vol. 6 (1) , 1
Abstract
In this research, we developed electrochemical biosensor which was composed of hemoglobin (Hb)-DNA conjugate on nanoporous gold thin film (NPGF) for hydrogen peroxide (H2O2) detection. For the first time, Hb and DNA was conjugated as a sensing platform for uniform orientation of Hb on electrode. The newly developed Hb-DNA conjugate was designed to prevent Hb from aggregation on electrode. DNA hybridization of Hb-DNA conjugate and complementary DNA (cDNA) on NPGF electrode induced uniformly assembled biosensor. Furthermore, NPGF electrode fabrication method was introduced to the increment of the surface area. To confirm the conjugation of Hb-DNA conjugate, sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) and ultraviolet–visible spectroscopy (UV–VIS) were used. Formation of the NPGF electrode was verified by scanning electron microscope (SEM). Atomic force microscopy (AFM) was operated for the confirmation of Hb-DNA immobilization on electrode. The electrochemical property of fabricated electrode was investigated by cyclic voltammetry (CV). Also, H2O2 sensing performance of fabricated electrode was investigated by amperometric i-t curve technique. This sensor showed a wide linear range from 0.00025 to 5.00 mM and a correlation coefficient of R2 = 0.9986. The detection limit was 250 nM. Proposed biosensor can be utilized as a sensing platform for development of biosensor.Keywords
Funding Information
- National Research Foundation of Korea (2013K1A4A3055268, 2016R1A6A1A03012845)
This publication has 28 references indexed in Scilit:
- Hyper, a Hydrogen Peroxide Sensor, Indicates the Sensitivity of the Arabidopsis Root Elongation Zone to Aluminum TreatmentSensors, 2015
- Electrochemical myoglobin biosensor based on carbon ionic liquid electrode modified with Fe3O4@SiO2 microsphereJournal of Solid State Electrochemistry, 2013
- An enzymatic biosensor for hydrogen peroxide based on CeO2 nanostructure electrodeposited on ITO surfaceBiosensors and Bioelectronics, 2013
- Amperometric sensor for hydrogen peroxide based on direct electron transfer of spinach ferredoxin on Au electrodeBioelectrochemistry, 2011
- Polyaniline based catalase biosensor for the detection of hydrogen peroxide and azideBiotechnology and Bioprocess Engineering, 2009
- Bioelectrochemistry2008
- A simple method to fabricate a chitosan-gold nanoparticles film and its application in glucose biosensorBioelectrochemistry, 2007
- Membrane transport of hydrogen peroxideBiochimica et Biophysica Acta (BBA) - Biomembranes, 2006
- Handbook on Metalloproteins2001
- Structural and Functional Aspects of Metal Sites in BiologyChemical Reviews, 1996