Jinhee Jo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jinhee Jo has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Jeong-Woo Choi
Department of Chemical & Biomolecular Engineering, Sogang University, Seoul, Republic of Korea
2 shared publications - Jinho Yoon
Department of Chemical & Biomolecular Engineering, Sogang University, 35 Baekbeom-Ro, Mapo-Gu, Seoul 04107, Korea
2 shared publications - Hyeon-Yeol Cho
Department of Bio & Fermentation Convergence Technology, Kookmin University, Seoul 02707, Republic of Korea
1 shared publication - Jae-Wook Shin
Department of Chemical and Biomolecular Engineering, Sogang University, 35 Baekbeom-ro, Mapo-gu, Seoul 04107, Korea
1 shared publication - Ji-Young Lee
Department of Chemical & Biomolecular Engineering, Sogang University, 35 Baekbeom-Ro, Mapo-Gu, Seoul 04107, Korea
1 shared publication - Kyeong-Jun Kim
Department of Chemical and Biomolecular Engineering, Sogang University, 35 Baekbeom-ro, Mapo-gu, Seoul 04107, Korea
1 shared publication
Latest Publications
- Open Access
- 3 January 2019
- Published by Springer Nature in Nano Convergence
- Vol. 6 (1) , 1
H2O2 biosensor consisted of hemoglobin-DNA conjugate on nanoporous gold thin film electrode with electrochemical signal enhancement
In this research, we developed electrochemical biosensor which was composed of hemoglobin (Hb)-DNA conjugate on nanoporous gold thin film (NPGF) for hydrogen peroxide (H2O2) detection. For the first time, Hb and DNA was conjugated as a sensing platform for uniform orientation of Hb on electrode. The newly developed Hb-DNA conjugate was designed to prevent Hb from aggregation on electrode. DNA hybridization of Hb-DNA conjugate and complementary DNA (cDNA) on NPGF electrode induced uniformly assembled biosensor. Furthermore, NPGF electrode fabrication method was introduced to the increment of the surface area. To confirm the conjugation of Hb-DNA conjugate, sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) and ultraviolet–visible spectroscopy (UV–VIS) were used. Formation of the NPGF electrode was verified by scanning electron microscope (SEM). Atomic force microscopy (AFM) was operated for the confirmation of Hb-DNA immobilization on electrode. The electrochemical property of fabricated electrode was investigated by cyclic voltammetry (CV). Also, H2O2 sensing performance of fabricated electrode was investigated by amperometric i-t curve technique. This sensor showed a wide linear range from 0.00025 to 5.00 mM and a correlation coefficient of R2 = 0.9986. The detection limit was 250 nM. Proposed biosensor can be utilized as a sensing platform for development of biosensor.
- 3 January 2019
- Published by Springer Nature in Nano Convergence
- Vol. 6 (1) , 1
Open AccessH2O2 biosensor consisted of hemoglobin-DNA conjugate on nanoporous gold thin film electrode with electrochemical signal enhancement
In this research, we developed electrochemical biosensor which was composed of hemoglobin (Hb)-DNA conjugate on nanoporous gold thin film (NPGF) for hydrogen peroxide (H2O2) detection. For the first time, Hb and DNA was conjugated as a sensing platform for uniform orientation of Hb on electrode. The newly developed Hb-DNA conjugate was designed to prevent Hb from aggregation on electrode. DNA hybridization of Hb-DNA conjugate and complementary DNA (cDNA) on NPGF electrode induced uniformly assembled biosensor. Furthermore, NPGF electrode fabrication method was introduced to the increment of the surface area. To confirm the conjugation of Hb-DNA conjugate, sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) and ultraviolet–visible spectroscopy (UV–VIS) were used. Formation of the NPGF electrode was verified by scanning electron microscope (SEM). Atomic force microscopy (AFM) was operated for the confirmation of Hb-DNA immobilization on electrode. The electrochemical property of fabricated electrode was investigated by cyclic voltammetry (CV). Also, H2O2 sensing performance of fabricated electrode was investigated by amperometric i-t curve technique. This sensor showed a wide linear range from 0.00025 to 5.00 mM and a correlation coefficient of R2 = 0.9986. The detection limit was 250 nM. Proposed biosensor can be utilized as a sensing platform for development of biosensor.
- Open Access
Silver Nanoparticle Modified Electrode Covered by Graphene Oxide for the Enhanced Electrochemical Detection of Dopamine
Several neurological disorders such as Alzheimer’s disease and Parkinson’s disease have become a serious impediment to aging people nowadays. One of the efficient methods used to monitor these neurological disorders is the detection of neurotransmitters such as dopamine. Metal materials, such as gold and platinum, are widely used in this electrochemical detection method; however, low sensitivity and linearity at low dopamine concentrations limit the use of these materials. To overcome these limitations, a silver nanoparticle (SNP) modified electrode covered by graphene oxide for the detection of dopamine was newly developed in this study. For the first time, the surface of an indium tin oxide (ITO) electrode was modified using SNPs and graphene oxide sequentially through the electrochemical deposition method. The developed biosensor provided electrochemical signal enhancement at low dopamine concentrations in comparison with previous biosensors. Therefore, our newly developed SNP modified electrode covered by graphene oxide can be used to monitor neurological diseases through electrochemical signal enhancement at low dopamine concentrations.
Open AccessSilver Nanoparticle Modified Electrode Covered by Graphene Oxide for the Enhanced Electrochemical Detection of Dopamine
Several neurological disorders such as Alzheimer’s disease and Parkinson’s disease have become a serious impediment to aging people nowadays. One of the efficient methods used to monitor these neurological disorders is the detection of neurotransmitters such as dopamine. Metal materials, such as gold and platinum, are widely used in this electrochemical detection method; however, low sensitivity and linearity at low dopamine concentrations limit the use of these materials. To overcome these limitations, a silver nanoparticle (SNP) modified electrode covered by graphene oxide for the detection of dopamine was newly developed in this study. For the first time, the surface of an indium tin oxide (ITO) electrode was modified using SNPs and graphene oxide sequentially through the electrochemical deposition method. The developed biosensor provided electrochemical signal enhancement at low dopamine concentrations in comparison with previous biosensors. Therefore, our newly developed SNP modified electrode covered by graphene oxide can be used to monitor neurological diseases through electrochemical signal enhancement at low dopamine concentrations.