Abstract
This study examined the relationships among the physical working capacity at the fatigue threshold (PWCFT), the power outputs associated with the gas exchange threshold (PGET) and the respiratory compensation point (PRCP), and critical power (CP) to identify possible physiological mechanisms underlying the onset of neuromuscular fatigue. Ten participants (mean ± SD age: 20 ± 1 years) performed a maximal incremental cycle ergometer test to determine the PWCFT, PGET, and PRCP. CP was determined from the 3 min all-out test. The PWCFT (197 ± 55 W), PRCP (212 ± 50 W), and CP (208 ± 63 W) were significantly greater than the PGET (168 ± 40 W), but there were no significant differences among the PWCFT, PRCP, and CP. All thresholds were significantly inter-4 (r = 0.794-0.958). The 17% greater estimates for the PWCFT than PGET were likely related to differences in the physiological mechanisms that underlie these fatigue thresholds, while the non-significant difference and high correlation between the PWCFT and the PRCP suggested that hyperkalemia may underlie both thresholds. Furthermore, it is possible that the 5% lower estimate of the PWCFT than CP could more accurately reflect the demarcation of the heavy from severe exercise intensity domains.Keywords
This publication has 53 references indexed in Scilit:
- The Relationships Among Critical Power Determined From a 3-Min All-Out Test, Respiratory Compensation Point, Gas Exchange Threshold, and Ventilatory ThresholdResearch Quarterly for Exercise and Sport, 2013
- Mechanomyographic and metabolic responses during continuous cycle ergometry at critical power from the 3-min all-out testJournal of Electromyography and Kinesiology, 2013
- Responses during exhaustive exercise at critical power determined from the 3-min all-out testJournal of Sports Sciences, 2013
- Metabolic and neuromuscular responses at critical power from the 3-min all-out testApplied Physiology, Nutrition, and Metabolism, 2013
- A New Single Work Bout Test to Estimate Critical Power and Anaerobic Work CapacityJournal of Strength & Conditioning Research, 2012
- Physiological responses during exercise to exhaustion at critical powerEuropean Journal of Applied Physiology, 2002
- Electromyographic and Mechanomyographic Responses at Critical PowerCanadian Journal of Applied Physiology, 2000
- Fascicle length of leg muscles is greater in sprinters than distance runnersMedicine & Science in Sports & Exercise, 2000
- Effect of mathematical modeling on the estimation of critical powerMedicine & Science in Sports & Exercise, 2000
- A new method for detecting anaerobic threshold by gas exchangeJournal of Applied Physiology, 1986