No adverse effects of submelt-annealed highly crosslinked polyethylene in cemented cups
Authors:
- Stephan M RöhrlSRStephan M Röhrl
- Bo NivbrantBNBo Nivbrant
- Kjell G NilssonKNKjell G Nilsson
Open Access
- 17 January 2012
- journal article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 83 (2) , 148-152
Abstract
Highly crosslinked polyethylene (PE) is in standard use worldwide. Differences in the crosslinking procedure may affect the clinical performance. Experimenatal data from retrieved cups have shown free radicals and excessive wear of annealed highly crosslinked PE. We have previously reported low wear and good clinical performance after 6 years with this implant, and now report on the 10-year results. In 8 patients, we measured wear of annealed highly crosslinked PE prospectively with radiostereometry after 10 years. Activity was assessed by UCLA activity score and a specifically designed activity score. Conventional radiographs were evaluated for osteolysis and clinical outcome by the Harris hip score (HHS). The mean (95% CI) proximal head penetration for highly crosslinked PE after 10 years was 0.07 (-0.015 to 0.153) mm, and the 3D wear was 0.2 (0.026 to 0.36) mm. Without creep, proximal head penetration was 0.02 (-0.026 to 0.066) mm and for 3D penetration was 0.016 (-0.47 to 0.08) mm. This represents an annual proximal wear of less than 2 µm. All cups were clinically and radiographically stable but showed a tendency of increased rotation after 5 years. Wear for annealed highly crosslinked PE is extremely low up to 10 years. Free radicals do not affect mechanical performance or lead to clinically adverse effects. Creep stops after the first 6 months after implantation. Highly crosslinked PE is a true competitor of hard-on-hard bearings.Keywords
This publication has 32 references indexed in Scilit:
- Less wear with aluminium-oxide heads than cobalt-chrome heads with ultra high molecular weight cemented polyethylene cups: A ten-year follow-up with radiostereometryInternational Orthopaedics, 2011
- History and Systematic Review of Wear and Osteolysis Outcomes for First-generation Highly Crosslinked PolyethyleneClinical Orthopaedics and Related Research, 2011
- Continued Improved Wear with an Annealed Highly Cross-linked PolyethyleneClinical Orthopaedics and Related Research, 2011
- Birmingham hip resurfacingThe Journal of Bone and Joint Surgery. British volume, 2010
- Metal–Metal Reactivity: Houston, We Have a Problem!Orthopedics, 2010
- Reasons for Revision of First-Generation Highly Cross-Linked PolyethylenesThe Journal of Arthroplasty, 2010
- The Effect of Serum Protein Concentration on Wear Rates in a Hip SimulatorJournal of Biomaterials Applications, 2009
- The creep and wear of highly cross-linked polyethyleneThe Journal of Bone and Joint Surgery. British volume, 2008
- Guidelines for standardization of radiostereometry (RSA) of implantsActa Orthopaedica, 2005
- The Mechanism of Loosening of Cemented Acetabular Components in Total Hip ArthroplastyClinical Orthopaedics and Related Research, 1992