Cartilage thickness at the apex of femoral resections in kinematically aligned total knee arthroplasty is close to 2.5 millimeters
Authors:
Open Access
- 1 January 2026
- journal article
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 13 (1)
Abstract
Purpose: Determining the correct resection thickness on worn femoral surfaces in kinematically aligned (KA) total knee arthroplasty (TKA) is uncertain since cartilage thickness is unknown. In the past, a 2 mm fixed adjustment has been used, but this may not reflect cartilage thickness at the apices of resections. Our objectives were to determine apex thickness for each resection based on a new method involving MR images, compare this thickness to direct measurements using calibrated photographs, and determine whether an increase in the 2 mm fixed adjustment is a refinement of interest to an already highly successful surgical procedure. Methods: MR images from 100 knees without evidence of OA were accessed in the Osteoarthritis Initiative (OAI) database. After aligning images in kinematic planes, the apices of the distal and posterior femoral resections were identified, and the apex cartilage thickness was computed. Results: From MR images and calibrated photographs, respectively, apex cartilage thickness was 2.3 mm ± 0.5 mm vs. 2.6 mm ± 0.7 mm for the distal medial resection, 2.3 mm ± 0.4 mm vs. 2.7 mm ± 0.6 mm for the distal lateral resection, 2.4 mm ± 0.5 mm vs. 2.7 mm ± 0.6 mm for the posterior medial resection, and 2.4 mm ± 0.6 mm vs 2.5 mm ± 0.5 mm for the posterior lateral resection. Mean differences were statistically significant ( p ≤ 0.0035) except for the posterior lateral cartilage thickness ( p = 0.1498). Conclusions: Apex cartilage thickness for MR image measurements was closer to 2.5 mm than 2 mm for all four resections. Apex cartilage thickness for calibrated photographs was greater than 2.5 mm and was comparable for all four resections. Although unlikely to affect patient‐reported outcome measures, a fixed adjustment for worn cartilage on the femur in KA TKA of 2.5 mm is a refinement of interest to bring more patients closer to the ideal alignment. Level of Evidence: N/A.Keywords
This publication has 17 references indexed in Scilit:
- Ball-in-socket medial conformity with posterior cruciate ligament retention neither limits internal tibial rotation and knee flexion nor lowers clinical outcome scores after unrestricted kinematically aligned total knee arthroplastyInternational Orthopaedics, 2023
- Deviations in femoral joint lines using calipered kinematically aligned TKA from virtually planned joint lines are small and do not affect clinical outcomesKnee Surgery, Sports Traumatology, Arthroscopy, 2019
- Variation in the Thickness of Knee Cartilage. The Use of a Novel Machine Learning Algorithm for Cartilage Segmentation of Magnetic Resonance ImagesThe Journal of Arthroplasty, 2019
- Cartilage thickness at the posterior medial femoral condyle is increased in femorotibial knee osteoarthritis: a cross-sectional CT arthrography study (Part 2)Osteoarthritis and Cartilage, 2015
- Femoral bone and cartilage wear is predictable at 0° and 90° in the osteoarthritic knee treated with total knee arthroplastyKnee Surgery, Sports Traumatology, Arthroscopy, 2014
- Accurate alignment and high function after kinematically aligned TKA performed with generic instrumentsKnee Surgery, Sports Traumatology, Arthroscopy, 2013
- Quantitative magnetic resonance imaging (MRI) morphological analysis of knee cartilage in healthy and anterior cruciate ligament‐injured kneesKnee Surgery, Sports Traumatology, Arthroscopy, 2011
- Femorotibial subchondral bone area and regional cartilage thickness: A cross‐sectional description in healthy reference cases and various radiographic stages of osteoarthritis in 1,003 knees from the Osteoarthritis InitiativeArthritis Care & Research, 2010
- Osteoarthritis may not be a one-way-road of cartilage loss – comparison of spatial patterns of cartilage change between osteoarthritic and healthy kneesOsteoarthritis and Cartilage, 2010
- Reliability, repeatability and reproducibility: analysis of measurement errors in continuous variablesUltrasound in Obstetrics & Gynecology, 2008