Maury L. Hull
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Maury L. Hull has a total of 440 co-authors. Here are the top co-authors by number of shared publications:
- Stephen Miller Howell
Department of Biomedical Engineering University of California at Davis Davis California USA
56 shared publications Stephen M. Howell
Department of Biomedical Engineering University of California Davis Davis California USA
29 shared publications- Alexander Johannes Nedopil
Department of Orthopaedic Surgery, König‐Ludwig‐Haus University of Würzburg Würzburg Germany
22 shared publications Alexander J. Nedopil
10 shared publicationsS. M. Howell
Department of Biomedical Engineering, University of California Davis, Davis, USA
9 shared publications- Abigail E. Niesen
Department of Biomedical Engineering, University of California , Davis One Shields Avenue, Davis, CA 95616
7 shared publications
Latest Publications
- Open Access
- 17 August 2026
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
A new cementless tibial baseplate in kinematically aligned total knee arthroplasty has low migration and stabilizes at 3 months: A cohort study using radiostereometric analysis
Purpose: Introduction of new components in total knee arthroplasty (TKA) should be assessed for long‐term stability. The primary objective was to determine whether migration of a new cementless tibial baseplate in kinematically aligned (KA) TKA is below the 6‐month threshold where baseplates have a low incidence of long‐term loosening. Other objectives were to determine when stability occurred, whether stability was associated with varus angles in knee and limb alignments, and whether a recut of the tibia affected migration. Methods: New cementless components were implanted in 45 patients, of which 38% had a tibial recut. Baseplate migration was assessed using model‐based radiostereometric analysis with radiographs obtained post‐operatively and at 6 weeks, 3 months and 6 months. Mean maximum total point motion (MTPM) at 6 months was compared to a 6‐month threshold where baseplates have low incidence of long‐term loosening. An equivalence analysis determined when stability occurred. Correlation analyses related MTPM at 6 months to the medial proximal tibial angle (MPTA) and the hip–knee–ankle angle (HKAA). A two‐sample t test determined whether mean MTPM differed between recut and non‐recut groups. Results: Mean 6‐month MTPM of 0.93 mm was significantly below the 6‐month stability threshold of 1.15 mm ( p = 0.015), and stability was achieved by 3 months. There was no significant relationship between MTPM and MPTA ( ρ = 0.050, p = 0.77) or HKAA ( ρ = 0.060, p = 0.72). Mean MTPM did not differ between recut (0.85 ± 0.56 mm) and non‐recut (0.97 ± 0.64 mm) groups ( p = 0.57). Conclusion: The new cementless tibial baseplate has migration significantly below the 6‐month threshold where baseplates have a low incidence of long‐term loosening and migration stabilizes early at 3 months. Varus alignment of the baseplate and the limb as well as tibial recuts were not associated with increased migration. Level of Evidence: N/A.
- 17 August 2026
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
Open AccessA new cementless tibial baseplate in kinematically aligned total knee arthroplasty has low migration and stabilizes at 3 months: A cohort study using radiostereometric analysis
Purpose: Introduction of new components in total knee arthroplasty (TKA) should be assessed for long‐term stability. The primary objective was to determine whether migration of a new cementless tibial baseplate in kinematically aligned (KA) TKA is below the 6‐month threshold where baseplates have a low incidence of long‐term loosening. Other objectives were to determine when stability occurred, whether stability was associated with varus angles in knee and limb alignments, and whether a recut of the tibia affected migration. Methods: New cementless components were implanted in 45 patients, of which 38% had a tibial recut. Baseplate migration was assessed using model‐based radiostereometric analysis with radiographs obtained post‐operatively and at 6 weeks, 3 months and 6 months. Mean maximum total point motion (MTPM) at 6 months was compared to a 6‐month threshold where baseplates have low incidence of long‐term loosening. An equivalence analysis determined when stability occurred. Correlation analyses related MTPM at 6 months to the medial proximal tibial angle (MPTA) and the hip–knee–ankle angle (HKAA). A two‐sample t test determined whether mean MTPM differed between recut and non‐recut groups. Results: Mean 6‐month MTPM of 0.93 mm was significantly below the 6‐month stability threshold of 1.15 mm ( p = 0.015), and stability was achieved by 3 months. There was no significant relationship between MTPM and MPTA ( ρ = 0.050, p = 0.77) or HKAA ( ρ = 0.060, p = 0.72). Mean MTPM did not differ between recut (0.85 ± 0.56 mm) and non‐recut (0.97 ± 0.64 mm) groups ( p = 0.57). Conclusion: The new cementless tibial baseplate has migration significantly below the 6‐month threshold where baseplates have a low incidence of long‐term loosening and migration stabilizes early at 3 months. Varus alignment of the baseplate and the limb as well as tibial recuts were not associated with increased migration. Level of Evidence: N/A.
- 16 February 2026
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 34 (11) , 4023-4031
A fixed 2 mm adjustment for worn distal femoral cartilage when the cartilage of the unworn compartment is ≥3 mm does not negatively affect outcome scores after kinematically aligned total knee arthroplasty
Purpose: A goal of kinematic alignment (KA) total knee arthroplasty (TKA) is to align the femoral component to restore the distal and posterior femoral joint lines to prearthritic. To restore the joint line on the worn distal condyle, the resection thickness is adjusted by 2 mm for cartilage loss based on the reported average cartilage thickness on magnetic resonance imaging. It remains unclear whether a 2 mm fixed adjustment is ideal for all patients, especially those with thicker cartilage. This study examined whether a 2 mm fixed adjustment in patients with cartilage thickness ≥3.0 mm negatively affects the Forgotten Joint Score (FJS), Oxford Knee Score (OKS) and Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS JR) compared to those with cartilage thickness p = 0.0150). Similarly, mean OKS scores of 42 versus 41 points ( p = 0.0071), and KOOS JR scores of 80 versus 81 points, were statistically equivalent ( p < 0.0001). Conclusion: Although a large percentage of patients had unworn cartilage thickness ≥3 mm, outcome scores were comparble to patients with thickness <3 mm. Hence, surgeons can use a 2 mm fixed adjustment for cartilage loss, even when the cartilage thickness exceeds 3 mm, with a range up to 5.0 mm, without negatively affecting the FJS, OKS or KOOS JR. Level of Evidence: Level III.
- 16 February 2026
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 34 (11) , 4023-4031
A fixed 2 mm adjustment for worn distal femoral cartilage when the cartilage of the unworn compartment is ≥3 mm does not negatively affect outcome scores after kinematically aligned total knee arthroplasty
Purpose: A goal of kinematic alignment (KA) total knee arthroplasty (TKA) is to align the femoral component to restore the distal and posterior femoral joint lines to prearthritic. To restore the joint line on the worn distal condyle, the resection thickness is adjusted by 2 mm for cartilage loss based on the reported average cartilage thickness on magnetic resonance imaging. It remains unclear whether a 2 mm fixed adjustment is ideal for all patients, especially those with thicker cartilage. This study examined whether a 2 mm fixed adjustment in patients with cartilage thickness ≥3.0 mm negatively affects the Forgotten Joint Score (FJS), Oxford Knee Score (OKS) and Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS JR) compared to those with cartilage thickness p = 0.0150). Similarly, mean OKS scores of 42 versus 41 points ( p = 0.0071), and KOOS JR scores of 80 versus 81 points, were statistically equivalent ( p < 0.0001). Conclusion: Although a large percentage of patients had unworn cartilage thickness ≥3 mm, outcome scores were comparble to patients with thickness <3 mm. Hence, surgeons can use a 2 mm fixed adjustment for cartilage loss, even when the cartilage thickness exceeds 3 mm, with a range up to 5.0 mm, without negatively affecting the FJS, OKS or KOOS JR. Level of Evidence: Level III.
- Open Access
- 1 January 2026
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 13 (1)
Cartilage thickness at the apex of femoral resections in kinematically aligned total knee arthroplasty is close to 2.5 millimeters
Purpose: Determining the correct resection thickness on worn femoral surfaces in kinematically aligned (KA) total knee arthroplasty (TKA) is uncertain since cartilage thickness is unknown. In the past, a 2 mm fixed adjustment has been used, but this may not reflect cartilage thickness at the apices of resections. Our objectives were to determine apex thickness for each resection based on a new method involving MR images, compare this thickness to direct measurements using calibrated photographs, and determine whether an increase in the 2 mm fixed adjustment is a refinement of interest to an already highly successful surgical procedure. Methods: MR images from 100 knees without evidence of OA were accessed in the Osteoarthritis Initiative (OAI) database. After aligning images in kinematic planes, the apices of the distal and posterior femoral resections were identified, and the apex cartilage thickness was computed. Results: From MR images and calibrated photographs, respectively, apex cartilage thickness was 2.3 mm ± 0.5 mm vs. 2.6 mm ± 0.7 mm for the distal medial resection, 2.3 mm ± 0.4 mm vs. 2.7 mm ± 0.6 mm for the distal lateral resection, 2.4 mm ± 0.5 mm vs. 2.7 mm ± 0.6 mm for the posterior medial resection, and 2.4 mm ± 0.6 mm vs 2.5 mm ± 0.5 mm for the posterior lateral resection. Mean differences were statistically significant ( p ≤ 0.0035) except for the posterior lateral cartilage thickness ( p = 0.1498). Conclusions: Apex cartilage thickness for MR image measurements was closer to 2.5 mm than 2 mm for all four resections. Apex cartilage thickness for calibrated photographs was greater than 2.5 mm and was comparable for all four resections. Although unlikely to affect patient‐reported outcome measures, a fixed adjustment for worn cartilage on the femur in KA TKA of 2.5 mm is a refinement of interest to bring more patients closer to the ideal alignment. Level of Evidence: N/A.
- 1 January 2026
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 13 (1)
Open AccessCartilage thickness at the apex of femoral resections in kinematically aligned total knee arthroplasty is close to 2.5 millimeters
Purpose: Determining the correct resection thickness on worn femoral surfaces in kinematically aligned (KA) total knee arthroplasty (TKA) is uncertain since cartilage thickness is unknown. In the past, a 2 mm fixed adjustment has been used, but this may not reflect cartilage thickness at the apices of resections. Our objectives were to determine apex thickness for each resection based on a new method involving MR images, compare this thickness to direct measurements using calibrated photographs, and determine whether an increase in the 2 mm fixed adjustment is a refinement of interest to an already highly successful surgical procedure. Methods: MR images from 100 knees without evidence of OA were accessed in the Osteoarthritis Initiative (OAI) database. After aligning images in kinematic planes, the apices of the distal and posterior femoral resections were identified, and the apex cartilage thickness was computed. Results: From MR images and calibrated photographs, respectively, apex cartilage thickness was 2.3 mm ± 0.5 mm vs. 2.6 mm ± 0.7 mm for the distal medial resection, 2.3 mm ± 0.4 mm vs. 2.7 mm ± 0.6 mm for the distal lateral resection, 2.4 mm ± 0.5 mm vs. 2.7 mm ± 0.6 mm for the posterior medial resection, and 2.4 mm ± 0.6 mm vs 2.5 mm ± 0.5 mm for the posterior lateral resection. Mean differences were statistically significant ( p ≤ 0.0035) except for the posterior lateral cartilage thickness ( p = 0.1498). Conclusions: Apex cartilage thickness for MR image measurements was closer to 2.5 mm than 2 mm for all four resections. Apex cartilage thickness for calibrated photographs was greater than 2.5 mm and was comparable for all four resections. Although unlikely to affect patient‐reported outcome measures, a fixed adjustment for worn cartilage on the femur in KA TKA of 2.5 mm is a refinement of interest to bring more patients closer to the ideal alignment. Level of Evidence: N/A.
- Open Access
- 1 October 2025
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 12 (4)
Caliper measurements of femoral resection thickness in kinematic alignment total knee arthroplasty are accurate and reproducible
Purpose: To resurface the patient's knee to the prearthritic state in caliper‐verified kinematic alignment (KA) total knee arthroplasty, the thickness of femoral resections after adjusting for saw blade kerf and wear should equal the femoral component. The primary objective was to determine accuracy of caliper measurement by quantifying the systematic (i.e., bias) and random (i.e., precision) errors of both unworn and worn articular surfaces from varus and valgus knees. The secondary objective was to assess reproducibility. Methods: In this diagnostic test study, thickness of each femoral resection from the first patients with 20 varus knees and the first patients with 20 valgus knees was measured by the surgeon using a caliper with 10 mm wide jaws. Subsequently, an optical method established the gold standard thickness. From the difference between caliper and optical measurements, the mean error (bias) and the standard deviation of the error (precision) were computed. Three observers measured resection thickness in three trials on both worn and unworn surfaces for 12 patients with varus knees. Repeatability and reproducibility were assessed by computing the variance components from a two‐factor analysis of variance and corresponding intraclass correlation coefficient (ICC) values. Results: For worn and unworn surfaces from both varus and valgus knees, the bias was negligible and the precision was less than or equal to the 0.5 mm resolution of the caliper. For worn and unworn surfaces from varus knees, ICC values were > 0.95 for both repeatability and reproducibility. Conclusions: The caliper used in this study is a sufficiently accurate tool for measuring resection thickness intraoperatively on worn and unworn femoral articular surfaces regardless of knee deformity. The error is less than the resolution of the caliper and the reproducibility is high thus giving surgeons confidence that the native limb and joint lines will be restored provided that the measured resection thickness after correcting for sawblade kerf and wear equals the femoral component thickness to within ±0.5 mm. Level of Evidence: N/A.
- 1 October 2025
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 12 (4)
Open AccessCaliper measurements of femoral resection thickness in kinematic alignment total knee arthroplasty are accurate and reproducible
Purpose: To resurface the patient's knee to the prearthritic state in caliper‐verified kinematic alignment (KA) total knee arthroplasty, the thickness of femoral resections after adjusting for saw blade kerf and wear should equal the femoral component. The primary objective was to determine accuracy of caliper measurement by quantifying the systematic (i.e., bias) and random (i.e., precision) errors of both unworn and worn articular surfaces from varus and valgus knees. The secondary objective was to assess reproducibility. Methods: In this diagnostic test study, thickness of each femoral resection from the first patients with 20 varus knees and the first patients with 20 valgus knees was measured by the surgeon using a caliper with 10 mm wide jaws. Subsequently, an optical method established the gold standard thickness. From the difference between caliper and optical measurements, the mean error (bias) and the standard deviation of the error (precision) were computed. Three observers measured resection thickness in three trials on both worn and unworn surfaces for 12 patients with varus knees. Repeatability and reproducibility were assessed by computing the variance components from a two‐factor analysis of variance and corresponding intraclass correlation coefficient (ICC) values. Results: For worn and unworn surfaces from both varus and valgus knees, the bias was negligible and the precision was less than or equal to the 0.5 mm resolution of the caliper. For worn and unworn surfaces from varus knees, ICC values were > 0.95 for both repeatability and reproducibility. Conclusions: The caliper used in this study is a sufficiently accurate tool for measuring resection thickness intraoperatively on worn and unworn femoral articular surfaces regardless of knee deformity. The error is less than the resolution of the caliper and the reproducibility is high thus giving surgeons confidence that the native limb and joint lines will be restored provided that the measured resection thickness after correcting for sawblade kerf and wear equals the femoral component thickness to within ±0.5 mm. Level of Evidence: N/A.
- Open Access
- 7 July 2025
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 33 (12) , 4291-4302
Restoration of the trochlear peaks is unnecessary with a kinematic alignment‐optimized femoral component as under‐stuffing results in equivalent or better patient‐reported outcome scores
Purpose: Kinematic alignment (KA) total knee arthroplasty (TKA) aligns the femoral component to restore the pre‐arthritic posterior joint line, potentially altering the heights of the medial and lateral trochlear peaks. It remains unclear whether the femoral component should be adjusted to correct deviations in peak height. This study assessed whether >2 mm of under‐ or over‐stuffing in peak height negatively impacted patient‐reported outcome (PRO) scores compared to restoration within ±2 mm. Methods: The study included 115 KA TKAs performed with a KA‐optimized femoral component featuring a trochlea with a lateral ridge opening that creates a 20° valgus trochlear groove and a flattened medial ridge, and PROs at a mean of 22 (12–28) months. The surgeon measured the height of the trochlear peaks on the anterior femoral resection. Results: Peak under‐stuffing >2 mm occurred medially in 66% and laterally in 43%. Over‐stuffing >2 mm was too infrequent for statistical analysis. Compared to restoration within ±2 mm, medial under‐stuffing resulted in a non‐equivalent 6‐point higher Forgotten Joint Score (FJS) ( p = 0.1087) and equivalent but 9‐ and 3‐point higher Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS JR) ( p < 0.0001) and Oxford Knee Score (OKS) ( p = 0.0020). Lateral under‐stuffing yielded equivalent but 6‐, 12‐ and 3‐point higher FJS ( p = 0.0484), KOOS JR ( p < 0.0001) and OKS ( p < 0.0001). Conclusion: The KA‐optimized femoral component features a patient‐specific trochlea that addresses anterior arthritic trochlear variations, which are reported to range from −24° varus to 30° valgus. One possible explanation for why >2 mm of under‐stuffing leads to superior PROs is that reducing the peak height compensates for over‐stuffing above the native trochlea caused by the prosthesis's proximal overreach, with a reported average of 17 mm. Level of Evidence: Level III.
- 7 July 2025
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 33 (12) , 4291-4302
Open AccessRestoration of the trochlear peaks is unnecessary with a kinematic alignment‐optimized femoral component as under‐stuffing results in equivalent or better patient‐reported outcome scores
Purpose: Kinematic alignment (KA) total knee arthroplasty (TKA) aligns the femoral component to restore the pre‐arthritic posterior joint line, potentially altering the heights of the medial and lateral trochlear peaks. It remains unclear whether the femoral component should be adjusted to correct deviations in peak height. This study assessed whether >2 mm of under‐ or over‐stuffing in peak height negatively impacted patient‐reported outcome (PRO) scores compared to restoration within ±2 mm. Methods: The study included 115 KA TKAs performed with a KA‐optimized femoral component featuring a trochlea with a lateral ridge opening that creates a 20° valgus trochlear groove and a flattened medial ridge, and PROs at a mean of 22 (12–28) months. The surgeon measured the height of the trochlear peaks on the anterior femoral resection. Results: Peak under‐stuffing >2 mm occurred medially in 66% and laterally in 43%. Over‐stuffing >2 mm was too infrequent for statistical analysis. Compared to restoration within ±2 mm, medial under‐stuffing resulted in a non‐equivalent 6‐point higher Forgotten Joint Score (FJS) ( p = 0.1087) and equivalent but 9‐ and 3‐point higher Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS JR) ( p < 0.0001) and Oxford Knee Score (OKS) ( p = 0.0020). Lateral under‐stuffing yielded equivalent but 6‐, 12‐ and 3‐point higher FJS ( p = 0.0484), KOOS JR ( p < 0.0001) and OKS ( p < 0.0001). Conclusion: The KA‐optimized femoral component features a patient‐specific trochlea that addresses anterior arthritic trochlear variations, which are reported to range from −24° varus to 30° valgus. One possible explanation for why >2 mm of under‐stuffing leads to superior PROs is that reducing the peak height compensates for over‐stuffing above the native trochlea caused by the prosthesis's proximal overreach, with a reported average of 17 mm. Level of Evidence: Level III.
- 26 April 2025
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 145 (1) , 1-8
Hip abduction force measurements accurately predict success for total hip arthroplasty patients
Background Whether hip abduction strength recovery influences patient-reported function is unknown. Consequently, in patients undergoing anterior-based muscle-sparing (ABMS) Total Hip Arthroplasty (THA), the present study determined: (1) the abduction torque ratio of the operative hip relative to the unaffected contralateral hip, and (2) whether an abduction torque ratio threshold is present, which is predictive of improved hip function at six weeks (≥ 11-point Oxford Hip Score improvement), and a successful outcome one year after THA (Forgotten Joint Score ≥ 74). Methods This study examined 118 consecutive patients undergoing ABMS THA with an unaffected contralateral hip. Bilateral peak isometric hip abduction torque was measured and compared at preoperative, 6-week, and 1-year time points to compute the abduction torque ratio. A non-inferiority test determined the significance of the comparison with a torque ratio ≥ 94% defining non-inferiority. A receiver operating characteristic curve analysis computed the threshold of abduction torque ratio associated with hip function improvement at six weeks and a successful outcome one year after THA. Results Mean (± standard deviation) abduction torque ratios and associated significance of the non-inferiority test before, 6 weeks, and 1 year after THA were 73 ± 14% (p = 1), 93 ± 5% (p = 0.99), and 98 ± 5% (p < 0.01). A 90% and 91% abduction torque ratio at 6 weeks and 1 year had a 0.8 and 1.0 positive predictive value, respectively, of improving hip function and a successful outcome. Conclusions A ≥ 91% abduction torque ratio is associated with a successful outcome after ABMS THA. Hence, a ≥ 91% abduction torque ratio provides a meaningful target when measuring abduction force and, if not achieved one year after THA, may prompt further investigation for causes of hip abduction weakness. Level of Evidence IV.
- 26 April 2025
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 145 (1) , 1-8
Hip abduction force measurements accurately predict success for total hip arthroplasty patients
Background Whether hip abduction strength recovery influences patient-reported function is unknown. Consequently, in patients undergoing anterior-based muscle-sparing (ABMS) Total Hip Arthroplasty (THA), the present study determined: (1) the abduction torque ratio of the operative hip relative to the unaffected contralateral hip, and (2) whether an abduction torque ratio threshold is present, which is predictive of improved hip function at six weeks (≥ 11-point Oxford Hip Score improvement), and a successful outcome one year after THA (Forgotten Joint Score ≥ 74). Methods This study examined 118 consecutive patients undergoing ABMS THA with an unaffected contralateral hip. Bilateral peak isometric hip abduction torque was measured and compared at preoperative, 6-week, and 1-year time points to compute the abduction torque ratio. A non-inferiority test determined the significance of the comparison with a torque ratio ≥ 94% defining non-inferiority. A receiver operating characteristic curve analysis computed the threshold of abduction torque ratio associated with hip function improvement at six weeks and a successful outcome one year after THA. Results Mean (± standard deviation) abduction torque ratios and associated significance of the non-inferiority test before, 6 weeks, and 1 year after THA were 73 ± 14% (p = 1), 93 ± 5% (p = 0.99), and 98 ± 5% (p < 0.01). A 90% and 91% abduction torque ratio at 6 weeks and 1 year had a 0.8 and 1.0 positive predictive value, respectively, of improving hip function and a successful outcome. Conclusions A ≥ 91% abduction torque ratio is associated with a successful outcome after ABMS THA. Hence, a ≥ 91% abduction torque ratio provides a meaningful target when measuring abduction force and, if not achieved one year after THA, may prompt further investigation for causes of hip abduction weakness. Level of Evidence IV.