Design and Integration of a Parallel, Soft Robotic End-Effector for Extracorporeal Ultrasound
- 4 December 2019
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 67 (8) , 2215-2229
Abstract
Objective: In this work we address limitations in state-of-the-art ultrasound robots by designing and integrating a novel soft robotic system for ultrasound imaging. It employs the inherent qualities of soft fluidic actuators to establish safe, adaptable interaction between ultrasound probe and patient. Methods: We acquire clinical data to determine the movement ranges and force levels required in prenatal foetal ultrasound imaging and design the soft robotic end-effector accordingly. We verify its mechanical characteristics, derive and validate a kinetostatic model and demonstrate controllability and imaging capabilities on an ultrasound phantom. Results: The soft robot exhibits the desired stiffness characteristics and is able to reach 100% of the required workspace when no external force is present, and 95% of the workspace when considering its compliance. The model can accurately predict the end-effector pose with a mean error of $\mathbf {1.18\pm 0.29}$ mm in position and $\mathbf {0.92\pm 0.47^{\circ }}$ in orientation. The derived controller is, with an average position error of 0.39 mm, able to track a target pose efficiently without and with externally applied loads. Ultrasound images acquired with the system are of equally good quality compared to a manual sonographer scan. Conclusion: The system is able to withstand loads commonly applied during foetal ultrasound scans and remains controllable with a motion range similar to manual scanning. Significance: The proposed soft robot presents a safe, cost-effective solution to offloading sonographers in day-to-day scanning routines. The design and modelling paradigms are greatly generalizable and particularly suitable for designing soft robots for physical interaction tasks.
Keywords
All Related Versions
Funding Information
- Wellcome Trust (102431)
- Engineering and Physical Sciences Research Council (EP/R013977/1)
This publication has 53 references indexed in Scilit:
- Automatic Localization of the da Vinci Surgical Instrument Tips in 3-D Transrectal UltrasoundIEEE Transactions on Biomedical Engineering, 2013
- Work-related repetitive strain injuries amongst practitioners of obstetric and gynaecological ultrasound worldwideArchives of Gynecology and Obstetrics, 2012
- Practice guidelines for performance of the routine mid‐trimester fetal ultrasound scanUltrasound in Obstetrics & Gynecology, 2010
- Work-Related Musculoskeletal Disorders (WRMSD) Among Registered Diagnostic Medical Sonographers and Vascular TechnologistsJournal of Diagnostic Medical Sonography, 2009
- Ambidextrous Sonographic Scanning to Reduce Sonographer Repetitive Strain InjuryJournal of Diagnostic Medical Sonography, 2008
- Echocardiography Versus Right-Sided Heart Catheterization Among Lung Transplantation CandidatesThe Annals of Thoracic Surgery, 2006
- Fetal tele‐echography using a robotic arm and a satellite linkUltrasound in Obstetrics & Gynecology, 2005
- The TERESA project : from space research to ground tele‐echographyIndustrial Robot: the international journal of robotics research and application, 2003
- Image-guided control of a robot for medical ultrasoundIEEE Transactions on Robotics and Automation, 2002
- A Robot System for Medical Ultrasound2000