JBJunghwan Back

Junghwan Back

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Junghwan Back has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Embedding Soft Material Channels for Tactile Sensing of Complex Surfaces—Light Propagation Modeling

    by Jian Hu, Jian Chen, Junghwan Back, Tianrui Zhao, Prokar Dasgupta, Hongbin Liu

    In previous work, “Embedding Softness into Structure ENabling distributed tactile sensing of high-order Curved Surfaces” (ESSENCE) technology, a general principle for accurate and robust tactile sensing on arbitrary surfaces, has been developed. Each tactel consists of a soft material sensing channel, a light source, and an optical receiver. Force applied on the tactel is transformed through the channel to cause an axial protrusion of the soft material. By measuring the change in light intensity caused by the protrusion, the magnitude of the force can be determined. However, multiple receivers share a single light source, resulting in lighting conditions in the region of interest (ROI) to vary from place to place, which in turn affects the consistency of sensing performance. To overcome this challenge, a freeform reflective funnel of the light source that is coated with a layer of high reflective material is designed to reshape the light distribution. Theoretical analysis and experimental results show that the proposed method improves the sensing consistency. For a 3 by 3 array-type sensor, the standard deviations of the force measuring range, linearity and sensitivity before and after using the freeform surface are 0.29N and 0.08N, 4.58% and 4.04%, 0.016 N−1 and 0.007 N−1, respectively.

  • OMsense: An Omni Tactile Sensing Principle Inspired by Compound Eyes

    by Chen Yu, Mingcong Chen, Mikel De Iturrate Reyzabal, Junghwan Back, Danqian Cao, Hongbin Liu

    Imitating the tactile sensory system of human and providing skin-like artificial sensing functions to robotic systems will enable them to interact with unstructured environment safely and efficiently. The vision-based method can achieve soft tactile sensing by the internal visual measurements and the conversion from deformation of an elastomer to haptic information. However, how to reduce the high requirements on both the pixel density of the images and the deformation quantity of the elastomer remains an open issue. Inspired by the compound eyes of the insects, a novel tactile sensing principle, the OMsense sensing principle, has been investigated. Arrays of lenses, acting as the facet lens in compound eyes, have been used for deformation magnification so that the required image pixels and the deformability of the elastomer can be significantly reduced. The contact shape and multiaxis force sensing relies on the soft silicone layer with designated pattern corresponding to the selected lenses. The OMsense has demonstrated high accuracy and low crosstalk in measuring all tactile information. Based on current sensor design, the resolution of normal force, shear force, and torque sensing was found to be 0.2 N, 0.5 N, and 0.003 N $ \cdot $ m, respectively. In OMsense, small and high sample rate image sensors with thinner and stiffer soft sensing layer can be used, which is particularly suitable for miniaturized three-dimensional structures.


  • Robotic Intra-Operative Ultrasound: Virtual Environments and Parallel Systems

    by Shuangyi Wang, James Housden, Tianxiang Bai, Hongbin Liu, Junghwan Back, Davinder Singh, Kawal Rhode, Zeng-Guang Hou, Fei-Yue Wang

    Robotic intra-operative ultrasound has the potential to improve the conventional practice of diagnosis and procedure guidance that are currently performed manually. Working towards automatic or semi-automatic ultrasound, being able to define ultrasound views and the corresponding probe poses via intelligent approaches become crucial. Based on the concept of parallel system which incorporates the ingredients of artificial systems, computational experiments, and parallel execution, this paper utilized a recent developed robotic trans-esophageal ultrasound system as the study object to explore the method for developing the corresponding virtual environments and present the potential applications of such systems. The proposed virtual system includes the use of 3D slicer as the main workspace and graphic user interface (GUI), Matlab engine to provide robotic control algorithms and customized functions, and PLUS (Public software Library for UltraSound imaging research) toolkit to generate simulated ultrasound images. Detailed implementation methods were presented and the proposed features of the system were explained. Based on this virtual system, example uses and case studies were presented to demonstrate its capabilities when used together with the physical TEE robot. This includes standard view definition and customized view optimization for pre-planning and navigation, as well as robotic control algorithm evaluations to facilitate real-time automatic probe pose adjustments. To conclude, the proposed virtual system would be a powerful tool to facilitate the further developments and clinical uses of the robotic intra-operative ultrasound systems.


  • Embedding Soft Material Channels for Tactile Sensing of Complex Surfaces—Mathematical Modeling

    by Jian Hu, Junghwan Back, Prokar Dasgupta, Hongbin Liu

    Currently most of tactile array technologies is difficult to cope with three dimensional complex surfaces and there is an urgent need to develop tactile sensors that can provide a high-density integrated array on a surface of arbitrary shape. Our laboratory has been working on the development of a novel tactile sensing technique to solve this challenge, by "Embedding Soft material into Structure ENabling Tactile sensing" of complex surfaces (ESSENT). This method creates sub-millimeter multiple channels filled with low compressibility elastic material. Tactile information is obtained by measuring the micro deformation of the soft material via projecting light to the material channel and measuring light reflection. However, the relationship between light reflection and soft material deformation is a complex function related to the geometry of reflective surface, elasticity of the soft channel and lighting conditions. To gain fundamental understanding of this new tactile sensing principle, we developed a mathematical model which is able to predict the precise deformation of the reflective surface of a soft material and provide the theoretical prediction of sensing sensitivity with respect to the lighting condition and the magnitude of the applied force. We demonstrated that the shape of soft material channel, the shape of reflective surface, as well as the location of light resource have significant influence on the sensor behavior.


  • Open Access

    A Variable-Dimension Overtube for Natural Orifice Transluminal Endoscopic Surgery

    by Yuyang Sun, Hongbin Liu, Shuxin Wang, Junghwan Back, Siyang Zuo, Julius E. Bernth, Guokai Zhang, Guohui Wang, Jianmin Li

    In natural orifice transluminal endoscopic surgery, the insertion of surgical instruments can cause patient discomfort, even bleeding and perforation. This paper proposes a design of an overtube which can vary its radial dimension. It can be inserted through the natural orifice in a small diameter configuration and then enlarge its size and form a hollow and rigid channel to allow passing instruments, while to reduce the friction between the instruments and the surrounding tissue. A Bricard linkage is used as the basic unit of the overtube and a mechanism is designed to drive multiple Bricard units to fold or unfold. Optimization of the design parameters has been studied and comparison experiments have been completed to verify the feasibility of the design on reducing the shear forces and normal forces exerted during surgical instrument insertion. The ex vivo experiment is also completed to prove the protection of the overtube on the esophagus during the insertion.


  • A Vision-Based Soft Somatosensory System for Distributed Pressure and Temperature Sensing

    by Chen Yu, Lukas Lindenroth, Jian Hu, Junghwan Back, George Abrahams, Hongbin Liu

    Emulating a human-like somatosensory system in instruments such as robotic hands and surgical grippers has the potential to revolutionize these domains. Using a combination of different sensing modalities is problematic due to the limited space and incompatibility of these sensing principles. Therefore, in contrast to the natural world, it is currently difficult to concurrently measure the force, geometry, and temperature of contact in conventional tactile sensing. To this end, here we present a soft multifunctional tactile sensing principle. The temperature is estimated using a thermochromic liquid crystal ink layer which exhibits colour variation under temperature change. The shape and force of contact is estimated through the 3D reconstruction of a deformed soft silicone surface. Our experiments have demonstrated high accuracy in all three modalities, which can be measured at the same time. The resolution of the distributed force and temperature sensing was found to be 0.7N and 0.4°C respectively.


  • Design and Integration of a Parallel, Soft Robotic End-Effector for Extracorporeal Ultrasound

    by Lukas Lindenroth, Richard James Housden, Shuangyi Wang, Junghwan Back, Kawal Rhode, Hongbin Liu

    Objective: In this work we address limitations in state-of-the-art ultrasound robots by designing and integrating a novel soft robotic system for ultrasound imaging. It employs the inherent qualities of soft fluidic actuators to establish safe, adaptable interaction between ultrasound probe and patient. Methods: We acquire clinical data to determine the movement ranges and force levels required in prenatal foetal ultrasound imaging and design the soft robotic end-effector accordingly. We verify its mechanical characteristics, derive and validate a kinetostatic model and demonstrate controllability and imaging capabilities on an ultrasound phantom. Results: The soft robot exhibits the desired stiffness characteristics and is able to reach 100% of the required workspace when no external force is present, and 95% of the workspace when considering its compliance. The model can accurately predict the end-effector pose with a mean error of $\mathbf {1.18\pm 0.29}$ mm in position and $\mathbf {0.92\pm 0.47^{\circ }}$ in orientation. The derived controller is, with an average position error of 0.39 mm, able to track a target pose efficiently without and with externally applied loads. Ultrasound images acquired with the system are of equally good quality compared to a manual sonographer scan. Conclusion: The system is able to withstand loads commonly applied during foetal ultrasound scans and remains controllable with a motion range similar to manual scanning. Significance: The proposed soft robot presents a safe, cost-effective solution to offloading sonographers in day-to-day scanning routines. The design and modelling paradigms are greatly generalizable and particularly suitable for designing soft robots for physical interaction tasks.


  • Open Access

    Motion Control of Cable-Driven Continuum Catheter Robot Through Contacts

    by Zhongkai Zhang, Jeremie Dequidt, Junghwan Back, Hongbin Liu, Christian Duriez


  • Design and Implementation of a Bespoke Robotic Manipulator for Extra-corporeal Ultrasound

    by Shuangyi Wang, James Housden, Yohan Noh, Anisha Singh, Junghwan Back, Lukas Lindenroth, Hongbin Liu, Joseph Hajnal, Kaspar Althoefer, Davinder Singh, et al.

    With the potential for high precision, dexterity, and repeatability, a self-tracked robotic system can be employed to assist the acquisition of real-time ultrasound. However, limited numbers of robots designed for extra-corporeal ultrasound have been successfully translated into clinical use. In this study, we aim to build a bespoke robotic manipulator for extra-corporeal ultrasound examination, which is lightweight and has a small footprint. The robot is formed by five specially shaped links and custom-made joint mechanisms for probe manipulation, to cover the necessary range of motion with redundant degrees of freedom to ensure the patient's safety. The mechanical safety is emphasized with a clutch mechanism, to limit the force applied to patients. As a result of the design, the total weight of the manipulator is less than 2 kg and the length of the manipulator is about 25 cm. The design has been implemented, and simulation, phantom, and volunteer studies have been performed, to validate the range of motion, the ability to make fine adjustments, mechanical reliability, and the safe operation of the clutch. This paper details the design and implementation of the bespoke robotic ultrasound manipulator, with the design and assembly methods illustrated. Testing results to demonstrate the design features and clinical experience of using the system are presented. It is concluded that the current proposed robotic manipulator meets the requirements as a bespoke system for extra-corporeal ultrasound examination and has great potential to be translated into clinical use.


  • Three-Axis Fiber-Optic Body Force Sensor for Flexible Manipulators

    by Yohan Noh, Sina Sareh, Helge Wurdemann, Hongbin Liu, Junghwan Back, James Housden, Kawal Rhode, Kaspar Althoefer

    This paper proposes a force/torque sensor structure that can be easily integrated into a flexible manipulator structure. The sensor's ring-like structure with its hollow inner section provides ample space for auxiliary components, such as cables and tubes, to be passed through and, hence, is very suitable for integration with tendon-driven and fluid-actuated manipulators. The sensor structure can also accommodate the wiring for a distributed sensor system as well as for diagnostic instruments that may be incorporated in the manipulator. Employing a sensing approach based on optical fibers as done here allows for the creation of sensors that are free of electrical currents at the point of sensing and immune to magnetic fields. These sensors are inherently safe when used in the close vicinity of humans and their measuring performance is not impaired when they are operated in or nearby machines, such as magnetic resonance imaging scanners. This type of sensor concept is particularly suitable for inclusion in instruments and robotic tools for minimally invasive surgery. This paper summarizes the design, integration challenges, and calibration of the proposed optical three-axis force sensor. The experimental results confirm the effectiveness of our optical sensing approach and show that after calibrating its stiffness matrix, force and momentum components can be determined accurately.