Investigation of the aptness of newly developed epoxy-based equivalent tissues for newborn and 5-years old in paediatric radiology
Preprint
Abstract
The varied radiological applications of tissue equivalent (TE) materials encompass quality checks, diagnostic imaging and dose evaluations. Nevertheless, the availability of compounds representative of paediatric patient tissues for scientific use in lower diagnostic photon energy spectra is limited. In this study, several TE substitutes were developed which replicate the radiographic characteristics of human tissue within these energy ranges, i.e. TE materials for neonatal soft tissue (ESST-NB), neonatal skeletal tissue (ESTB-NB), and the equivalent tissue types representative of a 5 year old child (ESST and ESBT, respectively). The ORNL stylised computational model series was used as a source for the desired elemental proportions. The density, effective atomic number, CT numbers and electron densities calculated for the developed tissue substitutes approximated those of the phantom system used as a reference. Additionally, in keeping with the material choice and production limitations, as close correlations as possible were achieved for all the materials in relation to the reference data for mass densities, mass attenuation coefficients and mass energy-absorption coefficients. The TE substitutes for the newborn over an energy range of 47 keV to 66 keV exhibited maximum discrepancies for {\mu}/\r{ho} of 1.6% to -3.01%, and for {\mu}_en/\r{ho} of 1.15% to -1.4% in relation to the ORNL reference samples. The respective equivalent data ranges were 1.09 % to -3.02% and 1.92% to -2.53% for the TE materials representative of a 5-year-old. Given the excellent concordance achieved between the newly constructed TE materials and the reference data, these compounds can subsequently be utilised to create physical phantoms representative of tissue types in neonates and children aged 5 years.Keywords
All Related Versions
This publication has 31 references indexed in Scilit:
- Investigation of the suitability of new developed epoxy based-phantom for child's tissue equivalency in paediatric radiologyNuclear Engineering and Technology, 2021
- An algorithm for noise correction of dual-energy computed tomography material density imagesInternational Journal of Computer Assisted Radiology and Surgery, 2014
- Creation of two tomographic voxel models of paediatric patients in the first year of lifePhysics in Medicine & Biology, 2002
- Production of phantom materials using polymer powder sintering under vacuumPhysics in Medicine & Biology, 2002
- Effects of x-ray spectra on the DQE of a computed radiography systemMedical Physics, 2001
- Derivation of linear attenuation coefficients from CT numbers for low-energy photonsPhysics in Medicine & Biology, 1999
- Introduction to Radiological Physics and Radiation Dosimetry1986
- Polyethylene-based water-equivalent phantom material for X-ray dosimetry at tube voltages from 10 to 100 kVPhysics in Medicine & Biology, 1985
- X-ray scatter data for diagnostic radiologyPhysics in Medicine & Biology, 1978
- The formulation of tissue substitute materials using basic interaction dataPhysics in Medicine & Biology, 1977