Nurul Ab. Aziz Hashikin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nurul Ab. Aziz Hashikin has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
Mohd Fahmi Mohd Yusof
School of Health Sciences, Universiti Sains Malaysia, Kubang Kerian, Malaysia
6 shared publicationsMuhammad Fahmi Rizal Abdul Hadi
Univ Sains Malaysia, Sch Phys, George Town 11800, Malaysia
6 shared publicationsRokiah Hashim
School of Industrial Technology, Universiti Sains Malaysia, USM, Malaysia
6 shared publicationsSiti Hajar Zuber
Univ Kebangsaan Malaysia, Fac Hlth Sci, Ctr Diagnost Therapeut & Invest Studies, Kuala Lumpur 50300, Malaysia
6 shared publicationsMohd Zahri Abdul Aziz
5 shared publicationsA Malaroda
Centre for Medical Radiation Physics, Faculty of Engineering and Information Sciences, University of Wollongong, Wollongong, New South Wales, 2522, AUSTRALIA
3 shared publications
Latest Publications
- Open Access
- 30 April 2025
- Published by Penerbit Universiti Sains Malaysia in Malaysian Journal of Medical Sciences
- Vol. 32 (2) , 32-41
Dosimetry Evaluation on the Use of 18F-FDG for PET/CT Imaging using OLINDA/EXM and Geant4 Monte Carlo Simulations – A Single Centre Experience
Background: PET/CT using 18F-FDG has been increasingly used for diagnostic imaging. Thus, dosimetry evaluation is crucial to minimise unnecessary radiation exposure to other organs. This study aimed to evaluate the absorbed dose to patients undergoing 18F-FDG sequential PET/CT imaging in the Institut Kanser Negara (IKN), Putrajaya, Malaysia using OLINDA/EXM and Geant4 MC simulation, focusing on identifying the most suitable method for clinical application and analysing whether the absorbed dose complies with the safety standard set by ICRP 128. Methods: OLINDA/EXM (version 1.1) and Geant4 MC (version 10.6.0) software were used to evaluate the absorbed doses to the liver, kidneys, and urinary bladder. MIRD-5 mathematical phantom was used in Geant4 MC simulation, whereas in OLINDA/EXM, adult male and female models with organ masses normalised to the Japanese reference model were applied. Results: The mean absorbed doses to the liver, kidneys, and urinary bladder were 0.010 ± 0.006 mGy/MBq, 0.011 ± 0.004 mGy/MBq, and 0.025 ± 0.047 mGy/MBq, respectively, for OLINDA/EXM, and 0.009 ± 0.004 mGy/MBq, 0.011 ± 0.003 mGy/MBq, and 0.073 ± 0.086 mGy/MBq, respectively, for Geant4 MC. The corresponding differences between these two methods were 10.526%, 0%, and 97.959%, respectively for the liver, kidneys, and urinary bladder. The results comply with the ICRP-128 limits, indicating the safe use of 18F-FDG for diagnostic purposes in IKN. Conclusion: Both methods were shown to be reliable in estimating the absorbed dose for 18F-FDG. The selection of the methods for absorbed dose estimation depends on the capacity of the clinics (i.e., in terms of time and computational capability [power and literacy]).
- 30 April 2025
- Published by Penerbit Universiti Sains Malaysia in Malaysian Journal of Medical Sciences
- Vol. 32 (2) , 32-41
Open AccessDosimetry Evaluation on the Use of 18F-FDG for PET/CT Imaging using OLINDA/EXM and Geant4 Monte Carlo Simulations – A Single Centre Experience
Background: PET/CT using 18F-FDG has been increasingly used for diagnostic imaging. Thus, dosimetry evaluation is crucial to minimise unnecessary radiation exposure to other organs. This study aimed to evaluate the absorbed dose to patients undergoing 18F-FDG sequential PET/CT imaging in the Institut Kanser Negara (IKN), Putrajaya, Malaysia using OLINDA/EXM and Geant4 MC simulation, focusing on identifying the most suitable method for clinical application and analysing whether the absorbed dose complies with the safety standard set by ICRP 128. Methods: OLINDA/EXM (version 1.1) and Geant4 MC (version 10.6.0) software were used to evaluate the absorbed doses to the liver, kidneys, and urinary bladder. MIRD-5 mathematical phantom was used in Geant4 MC simulation, whereas in OLINDA/EXM, adult male and female models with organ masses normalised to the Japanese reference model were applied. Results: The mean absorbed doses to the liver, kidneys, and urinary bladder were 0.010 ± 0.006 mGy/MBq, 0.011 ± 0.004 mGy/MBq, and 0.025 ± 0.047 mGy/MBq, respectively, for OLINDA/EXM, and 0.009 ± 0.004 mGy/MBq, 0.011 ± 0.003 mGy/MBq, and 0.073 ± 0.086 mGy/MBq, respectively, for Geant4 MC. The corresponding differences between these two methods were 10.526%, 0%, and 97.959%, respectively for the liver, kidneys, and urinary bladder. The results comply with the ICRP-128 limits, indicating the safe use of 18F-FDG for diagnostic purposes in IKN. Conclusion: Both methods were shown to be reliable in estimating the absorbed dose for 18F-FDG. The selection of the methods for absorbed dose estimation depends on the capacity of the clinics (i.e., in terms of time and computational capability [power and literacy]).
- 20 June 2024
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 223
Personalized 3D dosimetry of 90Y radioembolization: Monte Carlo simulation study using GATE
- 20 June 2024
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 223
Personalized 3D dosimetry of 90Y radioembolization: Monte Carlo simulation study using GATE
- 19 September 2023
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 214
Investigating the suitability of newly developed epoxy-based equivalent tissues for newborn and 5-year-old in paediatric radiology
- 19 September 2023
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 214
Investigating the suitability of newly developed epoxy-based equivalent tissues for newborn and 5-year-old in paediatric radiology
- 27 June 2023
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 199, 110916
Dosimetric assessment of Gadolinium-159 for hepatic radioembolization: Tomographic images and Monte Carlo simulation
- 27 June 2023
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 199, 110916
Dosimetric assessment of Gadolinium-159 for hepatic radioembolization: Tomographic images and Monte Carlo simulation
- Open Access
Dosimetric Characterization of DSF/NaOH/IA-PAE/R. spp. Phantom Material for Radiation Therapy
Background: Different compositions of DSF/NaOH/IA-PAE/R. spp. composite particleboard phantoms were constructed. Methods: Photon attenuation characteristics were ascertained using gamma rays from 137Cs and 60Co. Absorbed doses at the location of an ionization chamber and Gafchromic EBT3 radiochromic films were calculated for high-energy photons (6 and 10 MV) and electrons (6, 9, 12, and 15 MeV). Results: The calculated TPR20,10 values indicate that the percentage discrepancy for 6 and 10 MV was in the range of 0.29–0.72% and 0.26–0.65%. It was also found that the relative difference in the to water and solid water phantoms was between 1.08–1.28% and 5.42–6.70%. The discrepancies in the determination of PDD curves with 6, 9, 12, and 15 MeV, and those of water and solid water phantoms, ranged from 2.40–4.84%. Comparable results were found using the EBT3 films with variations of 2.0–7.0% for 6 and 10 MV photons. Likewise, the discrepancies for 6, 9, 12, and 15 MeV electrons were within an acceptable range of 2.0–4.5%. Conclusions: On the basis of these findings, the DSF/NaOH/IA-PAE/R. spp. particleboard phantoms with 15 wt% IA-PAE addition level can be effectively used as alternative tissue-equivalent phantom material for radiation therapy applications.Open AccessDosimetric Characterization of DSF/NaOH/IA-PAE/R. spp. Phantom Material for Radiation Therapy
Background: Different compositions of DSF/NaOH/IA-PAE/R. spp. composite particleboard phantoms were constructed. Methods: Photon attenuation characteristics were ascertained using gamma rays from 137Cs and 60Co. Absorbed doses at the location of an ionization chamber and Gafchromic EBT3 radiochromic films were calculated for high-energy photons (6 and 10 MV) and electrons (6, 9, 12, and 15 MeV). Results: The calculated TPR20,10 values indicate that the percentage discrepancy for 6 and 10 MV was in the range of 0.29–0.72% and 0.26–0.65%. It was also found that the relative difference in the to water and solid water phantoms was between 1.08–1.28% and 5.42–6.70%. The discrepancies in the determination of PDD curves with 6, 9, 12, and 15 MeV, and those of water and solid water phantoms, ranged from 2.40–4.84%. Comparable results were found using the EBT3 films with variations of 2.0–7.0% for 6 and 10 MV photons. Likewise, the discrepancies for 6, 9, 12, and 15 MeV electrons were within an acceptable range of 2.0–4.5%. Conclusions: On the basis of these findings, the DSF/NaOH/IA-PAE/R. spp. particleboard phantoms with 15 wt% IA-PAE addition level can be effectively used as alternative tissue-equivalent phantom material for radiation therapy applications. - Open Access
Investigation of the aptness of newly developed epoxy-based equivalent tissues for newborn and 5-years old in paediatric radiology
The varied radiological applications of tissue equivalent (TE) materials encompass quality checks, diagnostic imaging and dose evaluations. Nevertheless, the availability of compounds representative of paediatric patient tissues for scientific use in lower diagnostic photon energy spectra is limited. In this study, several TE substitutes were developed which replicate the radiographic characteristics of human tissue within these energy ranges, i.e. TE materials for neonatal soft tissue (ESST-NB), neonatal skeletal tissue (ESTB-NB), and the equivalent tissue types representative of a 5 year old child (ESST and ESBT, respectively). The ORNL stylised computational model series was used as a source for the desired elemental proportions. The density, effective atomic number, CT numbers and electron densities calculated for the developed tissue substitutes approximated those of the phantom system used as a reference. Additionally, in keeping with the material choice and production limitations, as close correlations as possible were achieved for all the materials in relation to the reference data for mass densities, mass attenuation coefficients and mass energy-absorption coefficients. The TE substitutes for the newborn over an energy range of 47 keV to 66 keV exhibited maximum discrepancies for {\mu}/\r{ho} of 1.6% to -3.01%, and for {\mu}_en/\r{ho} of 1.15% to -1.4% in relation to the ORNL reference samples. The respective equivalent data ranges were 1.09 % to -3.02% and 1.92% to -2.53% for the TE materials representative of a 5-year-old. Given the excellent concordance achieved between the newly constructed TE materials and the reference data, these compounds can subsequently be utilised to create physical phantoms representative of tissue types in neonates and children aged 5 years.
Open AccessInvestigation of the aptness of newly developed epoxy-based equivalent tissues for newborn and 5-years old in paediatric radiology
The varied radiological applications of tissue equivalent (TE) materials encompass quality checks, diagnostic imaging and dose evaluations. Nevertheless, the availability of compounds representative of paediatric patient tissues for scientific use in lower diagnostic photon energy spectra is limited. In this study, several TE substitutes were developed which replicate the radiographic characteristics of human tissue within these energy ranges, i.e. TE materials for neonatal soft tissue (ESST-NB), neonatal skeletal tissue (ESTB-NB), and the equivalent tissue types representative of a 5 year old child (ESST and ESBT, respectively). The ORNL stylised computational model series was used as a source for the desired elemental proportions. The density, effective atomic number, CT numbers and electron densities calculated for the developed tissue substitutes approximated those of the phantom system used as a reference. Additionally, in keeping with the material choice and production limitations, as close correlations as possible were achieved for all the materials in relation to the reference data for mass densities, mass attenuation coefficients and mass energy-absorption coefficients. The TE substitutes for the newborn over an energy range of 47 keV to 66 keV exhibited maximum discrepancies for {\mu}/\r{ho} of 1.6% to -3.01%, and for {\mu}_en/\r{ho} of 1.15% to -1.4% in relation to the ORNL reference samples. The respective equivalent data ranges were 1.09 % to -3.02% and 1.92% to -2.53% for the TE materials representative of a 5-year-old. Given the excellent concordance achieved between the newly constructed TE materials and the reference data, these compounds can subsequently be utilised to create physical phantoms representative of tissue types in neonates and children aged 5 years.
- Open Access
- 3 December 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (23) , 12396
Theranostic Investigation of Gadolinium-159 for Hepatocellular Carcinoma: Monte Carlo Simulation Study
Gadolinium-159 (159Gd) is a beta emitter with appropriate energy for therapeutic application. However, this radioisotope additionally emits gamma rays, enabling the distribution of 159Gd to be detected by a gamma camera after each therapeutic administration. The current research is innovative in the investigation of 159Gd as a theranostic radioisotope in the radioembolization of HCC using Monte Carlo (MC) simulation. For 159Gd therapeutic investigation, various patient scenarios including varying tumour involvement (TI), tumour-to-normal liver uptake ratio (T/N), and lung shunting (LS) were simulated using Geant4 MC to estimate the absorbed doses to organs at risk. For 159Gd planar imaging investigation, the SPECTHead example from GATEContrib (GitHub) was utilized, and inside a liver a tumour was created and placed inside a torso phantom and simulated using GATE MC simulation. The majority of 159Gd absorbed doses by normal liver and lungs were less than the maximum dose limitations of 70 Gy and 30 Gy, respectively. Absorbed doses to other organs were observed to be below 1 Gy. The utilization of 58 keV and 363.54 keV photopeaks in combination produced optimal planar imaging of 159Gd. This research gives new insights into the use of 159Gd as a theranostic radioisotope, with the potential to be used as an Yttrium-90 (90Y) alternative for liver radioembolization.
- 3 December 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (23) , 12396
Open AccessTheranostic Investigation of Gadolinium-159 for Hepatocellular Carcinoma: Monte Carlo Simulation Study
Gadolinium-159 (159Gd) is a beta emitter with appropriate energy for therapeutic application. However, this radioisotope additionally emits gamma rays, enabling the distribution of 159Gd to be detected by a gamma camera after each therapeutic administration. The current research is innovative in the investigation of 159Gd as a theranostic radioisotope in the radioembolization of HCC using Monte Carlo (MC) simulation. For 159Gd therapeutic investigation, various patient scenarios including varying tumour involvement (TI), tumour-to-normal liver uptake ratio (T/N), and lung shunting (LS) were simulated using Geant4 MC to estimate the absorbed doses to organs at risk. For 159Gd planar imaging investigation, the SPECTHead example from GATEContrib (GitHub) was utilized, and inside a liver a tumour was created and placed inside a torso phantom and simulated using GATE MC simulation. The majority of 159Gd absorbed doses by normal liver and lungs were less than the maximum dose limitations of 70 Gy and 30 Gy, respectively. Absorbed doses to other organs were observed to be below 1 Gy. The utilization of 58 keV and 363.54 keV photopeaks in combination produced optimal planar imaging of 159Gd. This research gives new insights into the use of 159Gd as a theranostic radioisotope, with the potential to be used as an Yttrium-90 (90Y) alternative for liver radioembolization.
- 1 July 2022
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 61 (3) , 435-443
Estimation of linear and mass attenuation coefficients of soy–lignin bonded Rhizophora spp. particleboard as a potential phantom material using caesium-137 and cobalt-60
In this study, linear and mass attenuation coefficients of fabricated particleboards intended for use as phantom material were estimated using 137Cs and 60Co radiation sources. Particleboards made of Rhizophora spp. wood trunk bonded with soy flour and lignin were fabricated at a target density of 1.0 g cm−3, with and without gloss finish coating. Elemental composition of the particleboards was obtained by means of energy dispersive X-ray (EDX) spectroscopy. Experimental setups were simulated via the GATE Monte Carlo (MC) package, with particle histories of 1 × 106–1 × 107. Linear and mass attenuation coefficients obtained from measurements and GATE simulations were compared and discussed. The percentage differences between the measured and simulated linear and mass attenuation coefficients of the samples were reasonably small (2.05–4.88% for 137Cs and 3.24–5.38% for 60Co). It is shown that all the particleboards have the potential to be used as phantom materials as the attenuation coefficients measured were in good agreement with those of water (calculated with XCOM) and with those simulated with the GATE toolkit. The use of gloss finish coating also did not show any significant effect on the attenuation coefficient of the phantom material. Verification of experimental results via GATE simulations has been shown crucial in providing reliable data for energy transmission studies. Based on the results achieved in this study, it is concluded that the studied material—Rhizophora spp. wood trunk bonded with soy flour and lignin including gloss finish coating—can be used in radiation dosimetry studies.
- 1 July 2022
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 61 (3) , 435-443
Estimation of linear and mass attenuation coefficients of soy–lignin bonded Rhizophora spp. particleboard as a potential phantom material using caesium-137 and cobalt-60
In this study, linear and mass attenuation coefficients of fabricated particleboards intended for use as phantom material were estimated using 137Cs and 60Co radiation sources. Particleboards made of Rhizophora spp. wood trunk bonded with soy flour and lignin were fabricated at a target density of 1.0 g cm−3, with and without gloss finish coating. Elemental composition of the particleboards was obtained by means of energy dispersive X-ray (EDX) spectroscopy. Experimental setups were simulated via the GATE Monte Carlo (MC) package, with particle histories of 1 × 106–1 × 107. Linear and mass attenuation coefficients obtained from measurements and GATE simulations were compared and discussed. The percentage differences between the measured and simulated linear and mass attenuation coefficients of the samples were reasonably small (2.05–4.88% for 137Cs and 3.24–5.38% for 60Co). It is shown that all the particleboards have the potential to be used as phantom materials as the attenuation coefficients measured were in good agreement with those of water (calculated with XCOM) and with those simulated with the GATE toolkit. The use of gloss finish coating also did not show any significant effect on the attenuation coefficient of the phantom material. Verification of experimental results via GATE simulations has been shown crucial in providing reliable data for energy transmission studies. Based on the results achieved in this study, it is concluded that the studied material—Rhizophora spp. wood trunk bonded with soy flour and lignin including gloss finish coating—can be used in radiation dosimetry studies.
- Open Access
Influence of Different Percentages of Binders on the Physico-Mechanical Properties of Rhizophora spp. Particleboard as Natural-Based Tissue-Equivalent Phantom for Radiation Dosimetry Applications
Rhizophora spp. particleboard with the incorporation of lignin and soy flour as binders were fabricated and the influence of different percentages of lignin and soy flour (0%, 6% and 12%) on the physico-mechanical properties of the particleboard were studied. The samples were characterised by Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), scanning electron microscopy (SEM), energy dispersive X-ray (EDX), X-ray fluorescence (XRF) and internal bonding. The results stipulated that the addition of binders in the fabrication of the particleboard did not change the functional groups according to the FTIR spectrum. For XRD, addition of binders did not reveal any major transformation within the composites. SEM and EDX analyses for all percentages of binders added showed no apparent disparity; however, it is important to note that the incorporation of binders allows better bonding between the molecules. In XRF analysis, lower percentage of chlorine in the adhesive-bonded samples may be advantageous in maintaining the natural properties of the particleboard. In internal bonding, increased internal bond strength in samples with binders may indicate better structural integrity and physico-mechanical strength. In conclusion, the incorporation of lignin and soy flour as binders may potentially strengthen and fortify the particleboard, thus, can be a reliable phantom in radiation dosimetry applications.
Open AccessInfluence of Different Percentages of Binders on the Physico-Mechanical Properties of Rhizophora spp. Particleboard as Natural-Based Tissue-Equivalent Phantom for Radiation Dosimetry Applications
Rhizophora spp. particleboard with the incorporation of lignin and soy flour as binders were fabricated and the influence of different percentages of lignin and soy flour (0%, 6% and 12%) on the physico-mechanical properties of the particleboard were studied. The samples were characterised by Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), scanning electron microscopy (SEM), energy dispersive X-ray (EDX), X-ray fluorescence (XRF) and internal bonding. The results stipulated that the addition of binders in the fabrication of the particleboard did not change the functional groups according to the FTIR spectrum. For XRD, addition of binders did not reveal any major transformation within the composites. SEM and EDX analyses for all percentages of binders added showed no apparent disparity; however, it is important to note that the incorporation of binders allows better bonding between the molecules. In XRF analysis, lower percentage of chlorine in the adhesive-bonded samples may be advantageous in maintaining the natural properties of the particleboard. In internal bonding, increased internal bond strength in samples with binders may indicate better structural integrity and physico-mechanical strength. In conclusion, the incorporation of lignin and soy flour as binders may potentially strengthen and fortify the particleboard, thus, can be a reliable phantom in radiation dosimetry applications.