Verification of dose distribution for volumetric modulated arc therapy total marrow irradiation in a humanlike phantom
- 21 December 2011
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 39 (1) , 281-288
Abstract
Purpose: Volumetric modulated arc therapy (VMAT) treatment planning studies have been reported to provide good target coverage and organs at risk (OARs) sparing in total marrow irradiation (TMI). A comprehensive dosimetric study simulating the clinical situation as close as possible is a norm in radiotherapy before a technique can be used to treat a patient. Without such a study, it would be difficult to make a reliable and safe clinical transition especially with a technique as complicated as VMAT-TMI. To this end, the dosimetric feasibility of VMAT-TMI technique in terms of treatment planning, delivery efficiency, and the most importantly three dimensional dose distribution accuracy was investigated in this study. The VMAT-TMI dose distribution inside a humanlike Rando phantom was measured and compared to the dose calculated using RapidArc especially in the field junctions and the inhomogeneous tissues including the lungs, which is the dose-limitingorgan in TMI. Methods: Three subplans with a total of nine arcs were used to treat the planning target volume (PTV), which was determined as all the bones plus the 3 mm margin. Thermoluminescent detectors(TLDs) were placed at 39 positions throughout the phantom. The measured TLDdoses were compared to the calculated plan doses. Planar dose for each arc was verified usingmapcheck. Results: TLD readings demonstrated accurate dose delivery, with a median dose difference of 0.5% (range: −4.3% and 6.6%) from the calculated dose in the junctions and in the inhomogeneous medium including the lungs. Conclusions: The results from this study suggest that RapidArc VMAT technique is dosimetrically accurate, safe, and efficient in delivering TMI within clinically acceptable time frame.Keywords
This publication has 36 references indexed in Scilit:
- Solid cancers after allogeneic hematopoietic cell transplantationBlood, 2009
- Targeted Total Marrow Irradiation Using Three-Dimensional Image-Guided Tomographic Intensity-Modulated Radiation Therapy: An Alternative to Standard Total Body IrradiationTransplantation and Cellular Therapy, 2006
- Long-term follow-up of secondary malignancies in adults after allogeneic bone marrow transplantationBone Marrow Transplantation, 2004
- Cataracts in patients receiving stem cell transplantation after conditioning with total body irradiationBone Marrow Transplantation, 2002
- Late effects of total body irradiation.Archives of Disease in Childhood, 1995
- Total-body irradiation and cataract incidence: A randomized comparison of two instantaneous dose ratesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1994
- Growth following single fraction and fractionated total body irradiation for bone marrow transplantationEuropean Journal of Pediatrics, 1993
- Ocular complications of bone marrow transplantation.British Journal of Ophthalmology, 1991
- Growth hormone treatment of growth failure secondary to total body irradiation and bone marrow transplantation.Archives of Disease in Childhood, 1991
- Secondary Cancers after Bone Marrow Transplantation for Leukemia or Aplastic AnemiaNew England Journal of Medicine, 1989