Bulent Aydogan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bulent Aydogan has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
Murat Surucu
Department of Radiation Oncology, Loyola University Medical Center, Maywood, IL, USA
3 shared publicationsArno J. Mundt
Department of Radiation Oncology University of California at San Diego 3855 Health Sciences Drive La Jolla, CA 92093, USA
2 shared publications- John C. Roeske
Loyola University Chicago
2 shared publications Neslihan Sarigul
Institute of Nuclear Science, Hacettepe University, Ankara, Turkey
2 shared publications- Andrew Wang
University of Chicago
1 shared publication Anil Sethi
Radiation Oncology Loyola University Medical Center Maywood IL 60153 USA
1 shared publication
Latest Publications
- Open Access
Sensitive detection and quantification of SARS-CoV-2 in saliva
Saliva has significant advantages as a test medium for detection of SARS-CoV-2 infection in patients, such as ease of collection, minimal requirement of supplies and trained personnel, and safety. Comprehensive validation in a large cohort of prospectively collected specimens with unknown SARS-CoV-2 status should be performed to evaluate the potential and limitations of saliva-based testing. We developed a saliva-based testing pipeline for detection of SARS-CoV-2 nucleic acids using real-time reverse transcription PCR (RT-PCR) and droplet digital PCR (ddPCR) readouts, and measured samples from 137 outpatients tested at a curbside testing facility and 29 inpatients hospitalized for COVID-19. These measurements were compared to the nasal swab results for each patient performed by a certified microbiology laboratory. We found that our saliva testing positively detects 100% (RT-PCR) and 93.75% (ddPCR) of curbside patients that were identified as SARS-CoV-2 positive by the Emergency Use Authorization (EUA) certified nasal swab testing assay. Quantification of viral loads by ddPCR revealed an extremely wide range, with 1 million-fold difference between individual patients. Our results demonstrate for both community screening and hospital settings that saliva testing reliability is on par with that of the nasal swabs in detecting infected cases, and has potential for higher sensitivity when combined with ddPCR in detecting low-abundance viral loads that evade traditional testing methods.
Open AccessSensitive detection and quantification of SARS-CoV-2 in saliva
Saliva has significant advantages as a test medium for detection of SARS-CoV-2 infection in patients, such as ease of collection, minimal requirement of supplies and trained personnel, and safety. Comprehensive validation in a large cohort of prospectively collected specimens with unknown SARS-CoV-2 status should be performed to evaluate the potential and limitations of saliva-based testing. We developed a saliva-based testing pipeline for detection of SARS-CoV-2 nucleic acids using real-time reverse transcription PCR (RT-PCR) and droplet digital PCR (ddPCR) readouts, and measured samples from 137 outpatients tested at a curbside testing facility and 29 inpatients hospitalized for COVID-19. These measurements were compared to the nasal swab results for each patient performed by a certified microbiology laboratory. We found that our saliva testing positively detects 100% (RT-PCR) and 93.75% (ddPCR) of curbside patients that were identified as SARS-CoV-2 positive by the Emergency Use Authorization (EUA) certified nasal swab testing assay. Quantification of viral loads by ddPCR revealed an extremely wide range, with 1 million-fold difference between individual patients. Our results demonstrate for both community screening and hospital settings that saliva testing reliability is on par with that of the nasal swabs in detecting infected cases, and has potential for higher sensitivity when combined with ddPCR in detecting low-abundance viral loads that evade traditional testing methods.
- 30 September 2020
- Published by Wiley in Medical Physics
- Vol. 47 (11) , 5455-5466
Dosimetric feasibility of brain stereotactic radiosurgery with a 0.35 T MRI‐guided linac and comparison vs a C‐arm‐mounted linac
Purpose: MRI is the gold‐standard imaging modality for brain tumor diagnosis and delineation. The purpose of this work was to investigate the feasibility of performing brain stereotactic radiosurgery (SRS) with a 0.35 T MRI‐guided linear accelerator (MRL) equipped with a double‐focused multileaf collimator (MLC). Dosimetric comparisons were made vs a conventional C‐arm‐mounted linac with a high‐definition MLC.Methods: The quality of MRL single‐isocenter brain SRS treatment plans was evaluated as a function of target size for a series of spherical targets with diameters from 0.6 cm to 2.5 cm in an anthropomorphic head phantom and six brain metastases (max linear dimension = 0.7‐1.9 cm) previously treated at our clinic on a conventional linac. Each target was prescribed 20 Gy to 99% of the target volume. Step‐and‐shoot IMRT plans were generated for the MRL using 11 static coplanar beams equally spaced over 360° about an isocenter placed at the center of the target. Couch and collimator angles are fixed for the MRL. Two MRL planning strategies (VR1 and VR2) were investigated. VR1 minimized the 12 Gy isodose volume while constraining the maximum point dose to be within ±1 Gy of 25 Gy which corresponded to normalization to an 80% isodose volume. VR2 minimized the 12 Gy isodose volume without the maximum dose constraint. For the conventional linac, the TB1 method followed the same strategy as VR1 while TB2 used five noncoplanar dynamic conformal arcs. Plan quality was evaluated in terms of conformity index (CI), conformity/gradient index (CGI), homogeneity index (HI), and volume of normal brain receiving ≥12 Gy (V12Gy). Quality assurance measurements were performed with Gafchromic EBT‐XD film following an absolute dose calibration protocol.Results: For the phantom study, the CI of MRL plans was not significantly different compared to a conventional linac (P > 0.05). The use of dynamic conformal arcs and noncoplanar beams with a conventional linac spared significantly more normal brain (P = 0.027) and maximized the CGI, as expected. The mean CGI was 95.9 ± 4.5 for TB2 vs 86.6 ± 3.7 (VR1), 88.2 ± 4.8 (VR2), and 88.5 ± 5.9 (TB1). Each method satisfied a normal brain V12Gy ≤ 10.0 cm3 planning goal for targets with diameter ≤2.25 cm. The mean V12Gy was 3.1 cm3 for TB2 vs 5.5 cm3, 5.0 cm3 and 4.3 cm3, for VR1, VR2, and TB1, respectively. For a 2.5‐cm diameter target, only TB2 met the V12Gy planning objective. The MRL clinical brain plans were deemed acceptable for patient treatment. The normal brain V12Gy was ≤6.0 cm3 for all clinical targets (maximum target volume = 3.51 cm3). CI and CGI ranged from 1.12–1.65 and 81.2–88.3, respectively. Gamma analysis pass rates (3%/1mm criteria) exceeded 97.6% for six clinical targets planned and delivered on the MRL. The mean measured vs computed absolute dose difference was −0.1%.Conclusions: The MRL system can produce clinically acceptable brain SRS plans for spherical lesions with diameter ≤2.25 cm. Large lesions (>2.25 cm) should be treated with a linac capable of delivering noncoplanar beams.
- 30 September 2020
- Published by Wiley in Medical Physics
- Vol. 47 (11) , 5455-5466
Dosimetric feasibility of brain stereotactic radiosurgery with a 0.35 T MRI‐guided linac and comparison vs a C‐arm‐mounted linac
Purpose: MRI is the gold‐standard imaging modality for brain tumor diagnosis and delineation. The purpose of this work was to investigate the feasibility of performing brain stereotactic radiosurgery (SRS) with a 0.35 T MRI‐guided linear accelerator (MRL) equipped with a double‐focused multileaf collimator (MLC). Dosimetric comparisons were made vs a conventional C‐arm‐mounted linac with a high‐definition MLC.Methods: The quality of MRL single‐isocenter brain SRS treatment plans was evaluated as a function of target size for a series of spherical targets with diameters from 0.6 cm to 2.5 cm in an anthropomorphic head phantom and six brain metastases (max linear dimension = 0.7‐1.9 cm) previously treated at our clinic on a conventional linac. Each target was prescribed 20 Gy to 99% of the target volume. Step‐and‐shoot IMRT plans were generated for the MRL using 11 static coplanar beams equally spaced over 360° about an isocenter placed at the center of the target. Couch and collimator angles are fixed for the MRL. Two MRL planning strategies (VR1 and VR2) were investigated. VR1 minimized the 12 Gy isodose volume while constraining the maximum point dose to be within ±1 Gy of 25 Gy which corresponded to normalization to an 80% isodose volume. VR2 minimized the 12 Gy isodose volume without the maximum dose constraint. For the conventional linac, the TB1 method followed the same strategy as VR1 while TB2 used five noncoplanar dynamic conformal arcs. Plan quality was evaluated in terms of conformity index (CI), conformity/gradient index (CGI), homogeneity index (HI), and volume of normal brain receiving ≥12 Gy (V12Gy). Quality assurance measurements were performed with Gafchromic EBT‐XD film following an absolute dose calibration protocol.Results: For the phantom study, the CI of MRL plans was not significantly different compared to a conventional linac (P > 0.05). The use of dynamic conformal arcs and noncoplanar beams with a conventional linac spared significantly more normal brain (P = 0.027) and maximized the CGI, as expected. The mean CGI was 95.9 ± 4.5 for TB2 vs 86.6 ± 3.7 (VR1), 88.2 ± 4.8 (VR2), and 88.5 ± 5.9 (TB1). Each method satisfied a normal brain V12Gy ≤ 10.0 cm3 planning goal for targets with diameter ≤2.25 cm. The mean V12Gy was 3.1 cm3 for TB2 vs 5.5 cm3, 5.0 cm3 and 4.3 cm3, for VR1, VR2, and TB1, respectively. For a 2.5‐cm diameter target, only TB2 met the V12Gy planning objective. The MRL clinical brain plans were deemed acceptable for patient treatment. The normal brain V12Gy was ≤6.0 cm3 for all clinical targets (maximum target volume = 3.51 cm3). CI and CGI ranged from 1.12–1.65 and 81.2–88.3, respectively. Gamma analysis pass rates (3%/1mm criteria) exceeded 97.6% for six clinical targets planned and delivered on the MRL. The mean measured vs computed absolute dose difference was −0.1%.Conclusions: The MRL system can produce clinically acceptable brain SRS plans for spherical lesions with diameter ≤2.25 cm. Large lesions (>2.25 cm) should be treated with a linac capable of delivering noncoplanar beams.
- Open Access
- 22 September 2020
- Published by Springer Nature in Cureus
- Vol. 12 (9) , e10592
Local Recurrence Following Total Marrow Radiation: Implications for Clinical Target Delineation
Total marrow radiation is an emerging treatment modality used in patients undergoing stem cell transplantation. We present a rare case of a patient undergoing total marrow irradiation with concurrent ablative stem cell transplantation with local failures in two out-of-field areas that were not included in the clinical target volume A 31-year-old female patient initially presented with abdominal pain secondary to chronic myelogenous leukemia. She underwent dasatinib treatment for years, hut subsequently developed recurrence and underwent consolidation systemic chemotherapy followed by allogeneic stem cell transplantation with adjuvant total marrow irradiation. Several months later, she noticed increased left jaw swelling and dysphagia with associated right ankle swelling. Biopsy of the right ankle and left mandible were consistent with recurrent myeloid sarcoma. This case report suggests that inclusion of the mandible and lower extremities may be necessary when performing total marrow radiation.
- 22 September 2020
- Published by Springer Nature in Cureus
- Vol. 12 (9) , e10592
Open AccessLocal Recurrence Following Total Marrow Radiation: Implications for Clinical Target Delineation
Total marrow radiation is an emerging treatment modality used in patients undergoing stem cell transplantation. We present a rare case of a patient undergoing total marrow irradiation with concurrent ablative stem cell transplantation with local failures in two out-of-field areas that were not included in the clinical target volume A 31-year-old female patient initially presented with abdominal pain secondary to chronic myelogenous leukemia. She underwent dasatinib treatment for years, hut subsequently developed recurrence and underwent consolidation systemic chemotherapy followed by allogeneic stem cell transplantation with adjuvant total marrow irradiation. Several months later, she noticed increased left jaw swelling and dysphagia with associated right ankle swelling. Biopsy of the right ankle and left mandible were consistent with recurrent myeloid sarcoma. This case report suggests that inclusion of the mandible and lower extremities may be necessary when performing total marrow radiation.
- 1 March 2020
- Published by Springer Nature
- p. 155-160
Linac-Based Total Marrow Irradiation (TMI)
- 26 February 2019
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 185 (3) , 303-309
ENERGY RESPONSE FACTOR of BeO DOSEMETER CHIPS: A MONTE CARLO SIMULATION AND GENERAL CAVITY THEORY STUDY
The objective of this study is to determine the energy response factors for BeO optically simulated dosemeter (OSLD) using general cavity theory and Monte Carlo (MC) simulations. A virtual phantom is constructed in EGSnrc MC program and energy response of BeO OSLDs were simulated at 5 cm depth for x-ray beams ranging from 1.25 to 25MV and at 2 cm for beams with <250 kV including ISO 4037 narrow beam energies in a virtual water phantom. The energy response factor for a given radiation quality relative to Co-60 was determined for BeO and compared to the Al2O3:C and LiF:Mg,Ti dosemeters. Burlin cavity theory calculations were done using mean photon energy (MPE) of the beam spectra, while EGSnrc software package was used to carry out MC simulation of full spectra. The cavity theory and MC methods agreed well within the 0.7%. Energy response of x-ray beams at MV range showed a maximum of 1.5% under-response. At energies higher than 150 kV (105 keV MPE) showed no significant difference while a significant under-response were observed at 100 kV (53 keV MPE) and 50 kV (29 keV MPE), similar to 8 and similar to 12%, respectively. BeO, Al2O3:C and LiF:Mg,Ti dosemeters exhibited very similar energy response at higher energies mainly in the MeV range. At 50 kV (29 keV MPE), however, BeO dosemeter under responded by a factor of 0.878, while Al2O3:C and LiF:Mg,Ti dosemeters over responded by a factor of 3.2 and 1.44, respectively. Furthermore, at low energies, BeO energy response showed dependence on photon spectra. For instance, at 100 kV, the difference was similar to 8, similar to 6 and 2% for 53, 60 and 83 keV MPE (ISO 4037N-100), respectively. Furthermore, calibration with Cs-137 instead of Co-60 resulted up to 1.8% differences in energy response. Both energy spectrum and calibration methods make considerable differences in energy response of OSLDs. This study concludes that BeO chips are nearly energy independent at energies higher than 100 keV MPE, while Al2O3:C dosemeters show an extremely enhanced energy-response ranging between 1.44 and 3.2 at energies between 170 and 29 keV MPE mainly due to dominance of photoelectric effect.
- 26 February 2019
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 185 (3) , 303-309
ENERGY RESPONSE FACTOR of BeO DOSEMETER CHIPS: A MONTE CARLO SIMULATION AND GENERAL CAVITY THEORY STUDY
The objective of this study is to determine the energy response factors for BeO optically simulated dosemeter (OSLD) using general cavity theory and Monte Carlo (MC) simulations. A virtual phantom is constructed in EGSnrc MC program and energy response of BeO OSLDs were simulated at 5 cm depth for x-ray beams ranging from 1.25 to 25MV and at 2 cm for beams with <250 kV including ISO 4037 narrow beam energies in a virtual water phantom. The energy response factor for a given radiation quality relative to Co-60 was determined for BeO and compared to the Al2O3:C and LiF:Mg,Ti dosemeters. Burlin cavity theory calculations were done using mean photon energy (MPE) of the beam spectra, while EGSnrc software package was used to carry out MC simulation of full spectra. The cavity theory and MC methods agreed well within the 0.7%. Energy response of x-ray beams at MV range showed a maximum of 1.5% under-response. At energies higher than 150 kV (105 keV MPE) showed no significant difference while a significant under-response were observed at 100 kV (53 keV MPE) and 50 kV (29 keV MPE), similar to 8 and similar to 12%, respectively. BeO, Al2O3:C and LiF:Mg,Ti dosemeters exhibited very similar energy response at higher energies mainly in the MeV range. At 50 kV (29 keV MPE), however, BeO dosemeter under responded by a factor of 0.878, while Al2O3:C and LiF:Mg,Ti dosemeters over responded by a factor of 3.2 and 1.44, respectively. Furthermore, at low energies, BeO energy response showed dependence on photon spectra. For instance, at 100 kV, the difference was similar to 8, similar to 6 and 2% for 53, 60 and 83 keV MPE (ISO 4037N-100), respectively. Furthermore, calibration with Cs-137 instead of Co-60 resulted up to 1.8% differences in energy response. Both energy spectrum and calibration methods make considerable differences in energy response of OSLDs. This study concludes that BeO chips are nearly energy independent at energies higher than 100 keV MPE, while Al2O3:C dosemeters show an extremely enhanced energy-response ranging between 1.44 and 3.2 at energies between 170 and 29 keV MPE mainly due to dominance of photoelectric effect.
- 1 November 2016
- Published by Elsevier in Radiation Measurements
- Vol. 94, 1-7
Examination of general cavity theory for magnesium and titanium doped lithium fluoride (TLD-100) of varying thicknesses in bone and lung
- 1 November 2016
- Published by Elsevier in Radiation Measurements
- Vol. 94, 1-7
Examination of general cavity theory for magnesium and titanium doped lithium fluoride (TLD-100) of varying thicknesses in bone and lung
- Open Access
- 8 May 2015
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 16 (3) , 297-304
Increased dose near the skin due to electromagnetic surface beacon transponder
- 8 May 2015
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 16 (3) , 297-304
Open AccessIncreased dose near the skin due to electromagnetic surface beacon transponder
- 21 December 2011
- Published by Wiley in Medical Physics
- Vol. 39 (1) , 281-288
Verification of dose distribution for volumetric modulated arc therapy total marrow irradiation in a humanlike phantom
Purpose: Volumetric modulated arc therapy (VMAT) treatment planning studies have been reported to provide good target coverage and organs at risk (OARs) sparing in total marrow irradiation (TMI). A comprehensive dosimetric study simulating the clinical situation as close as possible is a norm in radiotherapy before a technique can be used to treat a patient. Without such a study, it would be difficult to make a reliable and safe clinical transition especially with a technique as complicated as VMAT-TMI. To this end, the dosimetric feasibility of VMAT-TMI technique in terms of treatment planning, delivery efficiency, and the most importantly three dimensional dose distribution accuracy was investigated in this study. The VMAT-TMI dose distribution inside a humanlike Rando phantom was measured and compared to the dose calculated using RapidArc especially in the field junctions and the inhomogeneous tissues including the lungs, which is the dose-limitingorgan in TMI. Methods: Three subplans with a total of nine arcs were used to treat the planning target volume (PTV), which was determined as all the bones plus the 3 mm margin. Thermoluminescent detectors(TLDs) were placed at 39 positions throughout the phantom. The measured TLDdoses were compared to the calculated plan doses. Planar dose for each arc was verified usingmapcheck. Results: TLD readings demonstrated accurate dose delivery, with a median dose difference of 0.5% (range: −4.3% and 6.6%) from the calculated dose in the junctions and in the inhomogeneous medium including the lungs. Conclusions: The results from this study suggest that RapidArc VMAT technique is dosimetrically accurate, safe, and efficient in delivering TMI within clinically acceptable time frame.
- 21 December 2011
- Published by Wiley in Medical Physics
- Vol. 39 (1) , 281-288
Verification of dose distribution for volumetric modulated arc therapy total marrow irradiation in a humanlike phantom
Purpose: Volumetric modulated arc therapy (VMAT) treatment planning studies have been reported to provide good target coverage and organs at risk (OARs) sparing in total marrow irradiation (TMI). A comprehensive dosimetric study simulating the clinical situation as close as possible is a norm in radiotherapy before a technique can be used to treat a patient. Without such a study, it would be difficult to make a reliable and safe clinical transition especially with a technique as complicated as VMAT-TMI. To this end, the dosimetric feasibility of VMAT-TMI technique in terms of treatment planning, delivery efficiency, and the most importantly three dimensional dose distribution accuracy was investigated in this study. The VMAT-TMI dose distribution inside a humanlike Rando phantom was measured and compared to the dose calculated using RapidArc especially in the field junctions and the inhomogeneous tissues including the lungs, which is the dose-limitingorgan in TMI. Methods: Three subplans with a total of nine arcs were used to treat the planning target volume (PTV), which was determined as all the bones plus the 3 mm margin. Thermoluminescent detectors(TLDs) were placed at 39 positions throughout the phantom. The measured TLDdoses were compared to the calculated plan doses. Planar dose for each arc was verified usingmapcheck. Results: TLD readings demonstrated accurate dose delivery, with a median dose difference of 0.5% (range: −4.3% and 6.6%) from the calculated dose in the junctions and in the inhomogeneous medium including the lungs. Conclusions: The results from this study suggest that RapidArc VMAT technique is dosimetrically accurate, safe, and efficient in delivering TMI within clinically acceptable time frame.
- 1 February 2008
- Published by Radiation Research Society in Radiation Research
- Vol. 169 (2) , 223-231
Monte Carlo Simulations of Site-Specific Radical Attack to DNA Bases
An atomistic biophysical model permitting the calculation of initial attacks to a 38-bp representation of B-DNA base moieties by water radicals is presented. This model is based on a previous radiation damage model developed by Aydogan et al. (Radiat. Res. 157, 38-44, 2002). Absolute efficiencies for radical attack to the 38-bp DNA molecule are calculated to be 41, 0.8 and 15% for hydroxyl radical ((.)OH), hydrogen radical (H(.)), and hydrated electron (e(aq))(,) respectively. Among the nucleobases, guanine is found to have the highest percentage (.)OH attack probability at 36%. Adenine, cytosine and thymine moieties have initial attack probabilities of 24, 18 and 22%, respectively. A systematic study is performed to investigate (.)OH attack probabilities at each specified attack site in four molecular models including free bases, single nucleotides, single base pairs, and the central eight base pairs of the 38-bp DNA molecule. Cytosine is the free base moiety for which the closest agreement is observed between the model prediction and the experimental data. The initial (.)OH attack probabilities for cytosine as the free base are calculated to be 72 and 28%, while experimental data are reported at 87 and 13% for the C5 and C6 positions on the base, respectively. In this study, we incorporated atomic charges to scale the site-specific (.)OH reaction rates at the individual atomic positions on the pyrimidine and purine bases. Future updates to the RIDNA model will include the use of electron densities to scale the reaction rates. With respect to reactions of the aqueous electron with DNA, a comparison of the initial distribution of electron attack sites calculated in this study and experimental results suggests an extremely rapid and extensive redistribution of the e(-)(aq) after their initial reactions with DNA.
- 1 February 2008
- Published by Radiation Research Society in Radiation Research
- Vol. 169 (2) , 223-231
Monte Carlo Simulations of Site-Specific Radical Attack to DNA Bases
An atomistic biophysical model permitting the calculation of initial attacks to a 38-bp representation of B-DNA base moieties by water radicals is presented. This model is based on a previous radiation damage model developed by Aydogan et al. (Radiat. Res. 157, 38-44, 2002). Absolute efficiencies for radical attack to the 38-bp DNA molecule are calculated to be 41, 0.8 and 15% for hydroxyl radical ((.)OH), hydrogen radical (H(.)), and hydrated electron (e(aq))(,) respectively. Among the nucleobases, guanine is found to have the highest percentage (.)OH attack probability at 36%. Adenine, cytosine and thymine moieties have initial attack probabilities of 24, 18 and 22%, respectively. A systematic study is performed to investigate (.)OH attack probabilities at each specified attack site in four molecular models including free bases, single nucleotides, single base pairs, and the central eight base pairs of the 38-bp DNA molecule. Cytosine is the free base moiety for which the closest agreement is observed between the model prediction and the experimental data. The initial (.)OH attack probabilities for cytosine as the free base are calculated to be 72 and 28%, while experimental data are reported at 87 and 13% for the C5 and C6 positions on the base, respectively. In this study, we incorporated atomic charges to scale the site-specific (.)OH reaction rates at the individual atomic positions on the pyrimidine and purine bases. Future updates to the RIDNA model will include the use of electron densities to scale the reaction rates. With respect to reactions of the aqueous electron with DNA, a comparison of the initial distribution of electron attack sites calculated in this study and experimental results suggests an extremely rapid and extensive redistribution of the e(-)(aq) after their initial reactions with DNA.
- Open Access
- 1 October 2006
- Published by SAGE Publications in Technology in Cancer Research & Treatment
- Vol. 5 (5) , 513-519
Linac-Based Intensity Modulated Total Marrow Irradiation (IM-TMI)
Total body irradiation (TBI) has been used as a form of systemic therapy for the treatment of hematological malignancies and as a pre-conditioning regimen prior to bone marrow transplant. However, standard techniques are associated with both acute and chronic toxicities due to the large volumes of normal tissue irradiated. Intensity modulated radiation therapy (IMRT), with its ability to conform the high dose region to the shape of the target, offers a method to reduce radiation related sequelae and potentially allow for the delivery of higher than conventional doses. The goal of this study is to investigate the feasibility of a linac-based approach to intensity modulated total marrow irradiation (IM-TMI) and to discuss the challenges associated with its clinical implementation. The successful development of linac-based IM-TMI would represent advancement in the field of radiotherapy and potentially reduce the incidence and severity of complications associated with current TBI techniques.
- 1 October 2006
- Published by SAGE Publications in Technology in Cancer Research & Treatment
- Vol. 5 (5) , 513-519
Open AccessLinac-Based Intensity Modulated Total Marrow Irradiation (IM-TMI)
Total body irradiation (TBI) has been used as a form of systemic therapy for the treatment of hematological malignancies and as a pre-conditioning regimen prior to bone marrow transplant. However, standard techniques are associated with both acute and chronic toxicities due to the large volumes of normal tissue irradiated. Intensity modulated radiation therapy (IMRT), with its ability to conform the high dose region to the shape of the target, offers a method to reduce radiation related sequelae and potentially allow for the delivery of higher than conventional doses. The goal of this study is to investigate the feasibility of a linac-based approach to intensity modulated total marrow irradiation (IM-TMI) and to discuss the challenges associated with its clinical implementation. The successful development of linac-based IM-TMI would represent advancement in the field of radiotherapy and potentially reduce the incidence and severity of complications associated with current TBI techniques.