Augmented-Reality-Assisted K-Wire Placement for Glenoid Component Positioning in Reversed Shoulder Arthroplasty: A Proof-of-Concept Study
Open Access
- 10 August 2021
- journal article
- research article
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 11 (8) , 777
Abstract
The accuracy of the implant’s post-operative position and orientation in reverse shoulder arthroplasty is known to play a significant role in both clinical and functional outcomes. Whilst technologies such as navigation and robotics have demonstrated superior radiological outcomes in many fields of surgery, the impact of augmented reality (AR) assistance in the operating room is still unknown. Malposition of the glenoid component in shoulder arthroplasty is known to result in implant failure and early revision surgery. The use of AR has many promising advantages, including allowing the detailed study of patient-specific anatomy without the need for invasive procedures such as arthroscopy to interrogate the joint’s articular surface. In addition, this technology has the potential to assist surgeons intraoperatively in aiding the guidance of surgical tools. It offers the prospect of increased component placement accuracy, reduced surgical procedure time, and improved radiological and functional outcomes, without recourse to the use of large navigation or robotic instruments, with their associated high overhead costs. This feasibility study describes the surgical workflow from a standardised CT protocol, via 3D reconstruction, 3D planning, and use of a commercial AR headset, to AR-assisted k-wire placement. Post-operative outcome was measured using a high-resolution laser scanner on the patient-specific 3D printed bone. In this proof-of-concept study, the discrepancy between the planned and the achieved glenoid entry point and guide-wire orientation was approximately 3 mm with a mean angulation error of 5°.Keywords
This publication has 23 references indexed in Scilit:
- Instability in Reverse Total Shoulder ArthroplastyJournal of the American Academy of Orthopaedic Surgeons, 2018
- Use of Patient-Specific Instrumentation (PSI) for glenoid component positioning in shoulder arthroplasty. A systematic review and meta-analysisPLOS ONE, 2018
- Augmented Reality Based Navigation for Computer Assisted Hip Resurfacing: A Proof of Concept StudyAnnals of Biomedical Engineering, 2018
- Complications and revision of reverse total shoulder arthroplastyOrthopaedics & Traumatology: Surgery & Research, 2016
- Risk factors for revision after shoulder arthroplastyActa Orthopaedica, 2009
- Biomechanical comparison of component position and hardware failure in the reverse shoulder prosthesisJournal of Shoulder and Elbow Surgery, 2007
- 9: Complications and revision of the reverse prosthesis: A multicenter study of 457 casesJournal of Shoulder and Elbow Surgery, 2007
- Reverse Total Shoulder ArthroplastyJournal of Bone and Joint Surgery, 2006
- Augmented Reality and Its Future in OrthopaedicsClinical Orthopaedics and Related Research, 1998
- A method for registration of 3-D shapesIEEE Transactions on Pattern Analysis and Machine Intelligence, 1992