FTFabio Tatti

Fabio Tatti

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Fabio Tatti has a total of 51 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Recovery of Critical Raw Materials from extractive waste supported by AI algorithms within a geodata framework

    by Marco Aquino, Maria Gabriella Andrisani, Carlo Cipolloni, Maria Pia Congi, Stefano De Corso, Federica Ferrigno, Fiorenzo Fumanti, Andrea Massimiliano Lanz, Gabriele Leoni, Francesco Menniti, et al.

    The European Union’s dependence on extra-EU imports for Critical Raw Materials (CRMs) poses significant risks to strategic industries. Secondary resources, particularly extractive waste from abandoned mining sites, represent an underexploited opportunity to enhance supply security and circular economy objectives. This paper presents the URBES (Urban Mining and Extractive Waste Information System) project, an intelligent platform designed to integrate mineralogical, geochemical, and urban-resource datasets within a geodata framework for the systematic inventory, organisation, and preliminary screening of CRM-bearing secondary deposits in Italy. The datasets are developed in accordance with INSPIRE and M4EU standards and their extension within the mineral resources domain. This framework enables the application of artificial intelligence and machine-learning techniques to support data integration, information retrieval, and the prioritisation of secondary resources for further investigation, in line with the objectives of the Critical Raw Materials Act (Regulation (EU) 2024/1252), thereby providing a unified information framework for scientific research, environmental management, and policy implementation.

  • Novel robotic technology for the rapid intraoperative manufacture of patient-specific instrumentation allowing for improved glenoid component accuracy in shoulder arthroplasty: a cadaveric study

    by Alastair Darwood, Simon A. Hurst, Guillaume Villatte, Fabio Tatti, Hadi El Daou, Peter Reilly, Ferdinando Rodriguez Y. Baena, Addie Majed, Roger Emery


  • Open Access

    Augmented-Reality-Assisted K-Wire Placement for Glenoid Component Positioning in Reversed Shoulder Arthroplasty: A Proof-of-Concept Study

    by Klaus Schlueter-Brust, Johann Henckel, Faidon Katinakis, Christoph Buken, Jörg Opt-Eynde, Thorsten Pofahl, Ferdinando Rodriguez Y Baena, Fabio Tatti

    The accuracy of the implant’s post-operative position and orientation in reverse shoulder arthroplasty is known to play a significant role in both clinical and functional outcomes. Whilst technologies such as navigation and robotics have demonstrated superior radiological outcomes in many fields of surgery, the impact of augmented reality (AR) assistance in the operating room is still unknown. Malposition of the glenoid component in shoulder arthroplasty is known to result in implant failure and early revision surgery. The use of AR has many promising advantages, including allowing the detailed study of patient-specific anatomy without the need for invasive procedures such as arthroscopy to interrogate the joint’s articular surface. In addition, this technology has the potential to assist surgeons intraoperatively in aiding the guidance of surgical tools. It offers the prospect of increased component placement accuracy, reduced surgical procedure time, and improved radiological and functional outcomes, without recourse to the use of large navigation or robotic instruments, with their associated high overhead costs. This feasibility study describes the surgical workflow from a standardised CT protocol, via 3D reconstruction, 3D planning, and use of a commercial AR headset, to AR-assisted k-wire placement. Post-operative outcome was measured using a high-resolution laser scanner on the patient-specific 3D printed bone. In this proof-of-concept study, the discrepancy between the planned and the achieved glenoid entry point and guide-wire orientation was approximately 3 mm with a mean angulation error of 5°.


  • Automatic Calibration of Commercial Optical See-Through Head-Mounted Displays for Medical Applications

    by Xue Hu, Fabrizio Cutolo, Fabio Tatti, Ferdinando Rodriguez Y Baena

    The simplified, manual calibration of commercial Optical See-Through Head-Mounted Displays (OST-HMDs) is neither accurate nor convenient for medical applications. An interaction-free calibration method that can be easily implemented in commercial headsets is thus desired. State-of-the-art automatic calibrations simplify the eye-screen system as a pinhole camera and tedious offline calibrations are required. Furthermore, they have never been tested on original commercial products. We present a gaze-based automatic calibration method that can be easily implemented in commercial headsets without knowing hardware details. The location of the virtual target is revised in world coordinate according to the real-time tracked eye gaze. The algorithm has been tested with the Microsoft HoloLens. Current quantitative and qualitative user studies show that the automatically calibrated display is statistically comparable with the manually calibrated display under both monocular and binocular rendering mode. Since it is cumbersome to ask users to perform manual calibrations every time the HMD is re-positioned, our method provides a comparably accurate but more convenient and practical solution to the HMD calibration.


  • Open Access

    Towards a Commercial System for Intraoperative Manufacture of Patient-Specific Guides for Shoulder Arthroplasty

    by Alastair Darwood, Simon Hurst, Guillaume Villatte, Ryan Fenton, Fabio Tatti, Hadi El-Daou, Peter Reilly, Roger Emery, Ferdinando Rodriguez Y Baena

    The accurate placement of orthopaedic implants according to a biomechanically derived preoperative plan is an important consideration in the long-term success of these interventions. Guidance technologies are widely described however, high cost, complex theatre integration, intraoperative inefficiency and functional limitations have prevented the widespread use. A novel, intraoperative mechatronics platform is presented, capable of the rapid, intraoperative manufacture of low-cost patient-specific guides. The device consists of a tableside robot with sterile drapes and some low cost, sterile disposable components. The robot comprises a 3D optical scanner, a three-axis sterile computer numerical control (CNC) drill and a two-axis receptacle into which the disposable consumables may be inserted. The sterile consumable comprises a region of rapidly setting moldable material and a clip allowing it to be reversibly attached to the tableside robot. In use, patient computed tomography (CT) imaging is obtained at any point prior to surgery and a surgical plan is created on associated software. This plan describes the axis and positioning of one or more guidewires which may, in turn, locate the prosthesis into position. Intraoperatively, osseous anatomy is exposed, and the sterile disposable is used to rapidly create a mould of the joint surface. Once set, the mould is inserted into the robot and an optical scan of the surface is taken followed by automatic surface registration, bringing the optical scan into the same coordinate frame of reference as the CT data and plan. The CNC drill is orientated such that the drill axis and position exactly matches the planned axis and position with respect to the moulded surface. A guide hole is drilled into the mould blank, which is removed from the robot and placed back into the patient with the moulded surface ensuring exact replacement. A wire is subsequently driven through the guide hole into the osseous anatomy in accordance with the preoperative plan. The guide blank may be slid off the wire and discarded allowing the procedure to continue in the normal manner. A Pre-clinical prototype robot was constructed and used to insert guide wires into a 12 cadaveric shoulder arthroplasty specimens according to a ‘pre-operative’ plan. A ‘postoperative’ CT scan was used to assess accuracy with respect to the ‘pre-operative’ plan. Initial average end to end accuracy was 1.2 mm with respect to planned vs achieved glenoid point of entry and 2.2deg version, 1.6deg inclination with respect to planned vs achieved wire angle. These data demonstrate accuracy within the bounds of relevant literature with a significant margin for potential improvement.

  • Augmented-Reality within Computer Assisted Orthopaedic Surgery Workflows: A Proof of Concept Study

    by Hisham Iqbal, Fabio Tatti, Ferdinando Rodriguez Y Baena

    The integration of augmented-reality (AR) in medical robotics has been shown to reduce cognitive burden and improve information management in the typically cluttered environment of computer-assisted surgery. A key benefit of such systems is the ability to generate a composite view of medical-informatics and the real environment, streamlining the pathway for delivering patient-specific data. Consequently, AR was integrated within an orthopaedic setting by designing a system that captured and replicated the user- interface of a commercially available surgical robot onto a commercial head mounted see through display. Thus, a clinician could simultaneously view the operating-site and real- time informatics when carrying out an assisted patellofemoral-arthroplasty (PFA). The system was tested with 10 surgeons to examine its usability and impact on procedure- completion times when conducting simulated PFA on sawbone models. A statistically insignificant mean increase in procedure completion-time (+23.7s, p=0.240) was found, and the results of a post-operative qualitative-evaluation indicated a strongly positive consensus on the system, with a large majority of subjects agreeing the system provided value to the procedure without incurring noticeable physical discomfort. Overall, this study provides an encouraging insight into the high levels of engagement AR has with a clinical audience as well as its ability to enhance future generations of medical robotics.


  • Open Access

    Force sharing and other collaborative strategies in a dyadic force perception task

    by Fabio Tatti, Gabriel Baud-Bovy

    When several persons perform a physical task jointly, such as transporting an object together, the interaction force that each person experiences is the sum of the forces applied by all other persons on the same object. Therefore, there is a fundamental ambiguity about the origin of the force that each person experiences. This study investigated the ability of a dyad (two persons) to identify the direction of a small force produced by a haptic device and applied to a jointly held object. In this particular task, the dyad might split the force produced by the haptic device (the external force) in an infinite number of ways, depending on how the two partners interacted physically. A major objective of this study was to understand how the two partners coordinated their action to perceive the direction of the third force that was applied to the jointly held object. This study included a condition where each participant responded independently and another one where the two participants had to agree upon a single negotiated response. The results showed a broad range of behaviors. In general, the external force was not split in a way that would maximize the joint performance. In fact, the external force was often split very unequally, leaving one person without information about the external force. However, the performance was better than expected in this case, which led to the discovery of an unanticipated strategy whereby the person who took all the force transmitted this information to the partner by moving the jointly held object. When the dyad could negotiate the response, we found that the participant with less force information tended to switch his or her response more often.

  • Error feedback does not change response strategies in a joint force detection task

    by Fabio Tatti, Gabriel Baud-Bovy

    When two partners perform a joint physical task, each of them experiences a force that sums together a component generated by the partner and another generated from the environment. To investigate whether subjects are able to distinguish these two components, we created a force perception task in which two partners indicate the direction of an external force applied to a rigid bar that they grasp from opposite ends. In a previous study we showed that dyads adopt different response strategies and that many do not split the external force in a manner that allows both subjects to experience a meaningful interaction force. Here, we investigated whether a visual feedback on the partner's and correct response let dyads learn how to best split the external force. We show that this is not the case and that the dyads' force sharing and response strategies were comparable to those of the previous experiment.

  • Force sharing strategies in a collaborative force detection task

    by Fabio Tatti, Gabriel Baud-Bovy

    The haptic modality is a direct and informative communication channel when manipulating objects jointly, but it may also be difficult to interpret. Indeed, the forces generated by the partner and the environment are summed together. This work uses techniques from psychophysics to investigate the ability of humans to untangle these two sources when collaborating in a joint perceptual task where one subject's actions can have a strong impact on the partner's perception. We asked 16 pairs of subjects to perform a joint force detection task, in which they had to identify the direction of a weak external force. Results unveiled a variety of force sharing strategies adopted by the dyads. We present the different strategies adopted by the dyads and their implications on the subjects' task performance.


  • Ability of Low-Cost Force-Feedback Device to Influence Postural Stability

    by Gabriel Baud-Bovy, Fabio Tatti, Nunzio A. Borghese

    Low-cost gaming technology offers promising devices for the rehabilitation of stroke patients at home. While several attempts have been made to use low-cost motion tracking devices (Kinect) or balance boards (Wii Board), the potential of low-cost haptic devices has yet to be explored in this context. The objective of this study was to investigate whether it is possible to influence postural stability with a low-cost device despite its technical limitations, and to explore the most promising modes of haptic interaction to increase and decrease postural stability. Two groups of younger subjects used a high-end (Omega.3) and a low-cost (Falcon) device respectively. A third group of older subjects used the Falcon. We show that light touch contact with the device improves stability, whereas the force tasks decrease it. The effects of the different tasks are consistent in the two age groups. Although there are differences in the participants' interaction with the two devices, the effect of the devices on postural stability is comparable. We conclude that a low-cost haptic device can be used to increase or decrease postural stability of healthy subjects with an age similar to that of typical stroke patients, in a safe and controllable way.