High-accuracy measurement system for the refractive index of air based on a simple double-beam interferometry
- 8 January 2021
- journal article
- research article
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (2) , 1396-1411
Abstract
A measurement system based on a simple double-beam interferometry is built to realize the measurement of air refractive index with high accuracy. The basic principle of the system is that, through measuring the change of optical path difference caused by rapid and smooth vacuumization, measurement of refractive index of air is converted to length measurement. Error correction and signal processing are studied to ensure high-accuracy measurement of the refractive index of air. Three applicable methods are used in system. The system based on the methods realize the subdivision and counting of interference fringe by software with three-error correction, error compensation for the end-window plates’ thickness change caused by vacuumization, steady realization of high vacuum conditions. To verify the accuracy and reliability of the system, the measurement results are compared with that obtained from the method based on empirical Edlén’s formula. Analysis result shows that the expanded measurement uncertainty of the system is U = 5×10−9, with k = 2. The system can be used to compensate the laser wavelength error caused by the refractive index of air with high accuracy.Keywords
Funding Information
- National Key Research and Development Program of China (2017YFF0204803)
- Capacity Improvement Program of the State Administration for Market Regulation of China (24-ANL1804)
- Ministry of Industry and Information Technology of the People's Republic of China (MJ-2018-J-70)
This publication has 19 references indexed in Scilit:
- Air cavity-based Fabry–Perot interferometer sensor fabricated using a sawing technique for refractive index measurementOptical Engineering, 2014
- High-accuracy correction of air refractive index by using two-color heterodyne interferometry of optical frequency combsMeasurement Science and Technology, 2012
- Absolute refractometry of dry gas to ±3 parts in 10^9Applied Optics, 2011
- Novel method for measurement of effective cavity length of DBR fiberChinese Optics Letters, 2010
- Measurement of the refractive index of air and comparison with modified Edl n's formulaeMetrologia, 1998
- Correction of nonlinearity in one-frequency optical interferometryMeasurement Science and Technology, 1996
- An Updated Edlén Equation for the Refractive Index of AirMetrologia, 1993
- Cavity length measurement for synchronously pumped, mode-locked lasersOptics Communications, 1986
- The Refractive Index of AirMetrologia, 1966
- The Dispersion of Standard Air*Journal of the Optical Society of America, 1953