Wei Zou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Wei Zou has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Yao Huang
National Institute of Metrology
5 shared publications - Zi Xue
National Institute of Metrology
5 shared publications - Hu Lin
National Institute of Metrology, Chaoyang, Beijing, China
2 shared publications - Shuangliang Che
State Key Laboratory of Modern Optical Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou 310027, China
2 shared publications - Weibin Zhu
China Jiliang University
2 shared publications - Cheng Ma1 shared publication
Latest Publications
- 1 October 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (40) , 405004
A new technology for static and dynamic calibration of angle errors in multi-axis rotary tables
The traditional approach for calibrating the angular position error of a rotary table involves employing an autocollimator coupled with a polygon mirror, or alternatively, utilizing an interferometer coupled with a precision wireless rotary table equipped with a mirror. These approachs require that the standard polygon mirror or standard rotary table be concentric or coaxial with the rotary table being calibrated, so that the angular position of the rotary table can be compared with the standard angle. However, with the widespread application of multi-axis CNC machine tools, which typically consist of multi-axis rotary tables and linear platforms, the centerline of the rotary axis is not parallel to the normal direction of the worktable surface, making the conventional method for calibrating the angular position error of the rotary table inapplicable. This paper develops an optical gyroscope goniometer based on the Sagnac principle to achieve high-accuracy angular position at any position on site. Laboratory and online measurement results, indicate that the angular position error is better than ± 0.3 ′ ′ , and the repeatability is better than 0.2 ′ ′ , which can meet the calibration requirements for angular position errors of CNC rotary tables in CNC machine tools.
- 1 October 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (40) , 405004
A new technology for static and dynamic calibration of angle errors in multi-axis rotary tables
The traditional approach for calibrating the angular position error of a rotary table involves employing an autocollimator coupled with a polygon mirror, or alternatively, utilizing an interferometer coupled with a precision wireless rotary table equipped with a mirror. These approachs require that the standard polygon mirror or standard rotary table be concentric or coaxial with the rotary table being calibrated, so that the angular position of the rotary table can be compared with the standard angle. However, with the widespread application of multi-axis CNC machine tools, which typically consist of multi-axis rotary tables and linear platforms, the centerline of the rotary axis is not parallel to the normal direction of the worktable surface, making the conventional method for calibrating the angular position error of the rotary table inapplicable. This paper develops an optical gyroscope goniometer based on the Sagnac principle to achieve high-accuracy angular position at any position on site. Laboratory and online measurement results, indicate that the angular position error is better than ± 0.3 ′ ′ , and the repeatability is better than 0.2 ′ ′ , which can meet the calibration requirements for angular position errors of CNC rotary tables in CNC machine tools.
- 26 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
A Flexible and High-Precision Perpendicularity Measurement Method of Multiaxis Turntables Based on Single-Axis Laser Gyro Goniometer
This paper gives a new application of laser gyro in the field of metrology, that is, the perpendicularity measurement method between two axes of multi-axis turntables based on single-axis laser gyro goniometer. This method skillfully establishes different coordinate frames on the turntable and uses the projection variation of the sensitive axis of the laser gyro in the coordinate frame to solve the perpendicularity. This method can also accurately solve the misalignment angle of the laser gyro goniometer at the same time. It is suitable for online measurement of perpendicularity between the axes of multi-axis turntables in fields such as CNC machine tools, robots, flight simulation, and inertial testing. This method has simple equipment installation, convenient measurement operation, high measurement accuracy (the measurement uncertainty is U = 0.23′′ (k = 2), and fully utilizes the dynamic characteristics of the laser gyro goniometer.
- 26 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
A Flexible and High-Precision Perpendicularity Measurement Method of Multiaxis Turntables Based on Single-Axis Laser Gyro Goniometer
This paper gives a new application of laser gyro in the field of metrology, that is, the perpendicularity measurement method between two axes of multi-axis turntables based on single-axis laser gyro goniometer. This method skillfully establishes different coordinate frames on the turntable and uses the projection variation of the sensitive axis of the laser gyro in the coordinate frame to solve the perpendicularity. This method can also accurately solve the misalignment angle of the laser gyro goniometer at the same time. It is suitable for online measurement of perpendicularity between the axes of multi-axis turntables in fields such as CNC machine tools, robots, flight simulation, and inertial testing. This method has simple equipment installation, convenient measurement operation, high measurement accuracy (the measurement uncertainty is U = 0.23′′ (k = 2), and fully utilizes the dynamic characteristics of the laser gyro goniometer.
- 26 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
New Application and Research of Ring Laser Gyroscope in the Field of Angle Metrology
Ring laser gyroscope is one of the most important equipment in high-precision strapdown inertial navigation systems, and has been widely used in the field of navigation. At present, there is little research on the application of ring laser gyroscope on the angle error measurement of sub-arc-second in the metrology field, and it has not been officially used as the metrology standard instrument. Aiming at the inaccurate measurement of ring laser gyroscope in metrology due to zero position drift and non-coplanar installation, a non-contact high-precision angle measurement error measurement method is proposed in this paper. Firstly, the original scale factor is calculated on the standard rotating device to avoid re-calculated on the measured device and solve the traceability problem. Secondly, the influence of the installation error between the turntable and the laser gyroscope goniometer on the angle measurement error is analyzed, and the compensation method of angle measurement error in the online measurement of the laser gyroscope is proposed. Finally, the feasibility of online metrology of ring laser gyroscope is verified by experiments, and the measurement uncertainty is estimated. The online measurement results show that compared with the photoelectric autocollimator (measurement uncertainty is U = 0.07ʺ ( k = 2), the angle measurement error of the ring laser gyroscope goniometer in multi-axis turntable is ±0.4ʺ, and the measurement uncertainty is U = 0.36ʺ ( k = 2).
- 26 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
New Application and Research of Ring Laser Gyroscope in the Field of Angle Metrology
Ring laser gyroscope is one of the most important equipment in high-precision strapdown inertial navigation systems, and has been widely used in the field of navigation. At present, there is little research on the application of ring laser gyroscope on the angle error measurement of sub-arc-second in the metrology field, and it has not been officially used as the metrology standard instrument. Aiming at the inaccurate measurement of ring laser gyroscope in metrology due to zero position drift and non-coplanar installation, a non-contact high-precision angle measurement error measurement method is proposed in this paper. Firstly, the original scale factor is calculated on the standard rotating device to avoid re-calculated on the measured device and solve the traceability problem. Secondly, the influence of the installation error between the turntable and the laser gyroscope goniometer on the angle measurement error is analyzed, and the compensation method of angle measurement error in the online measurement of the laser gyroscope is proposed. Finally, the feasibility of online metrology of ring laser gyroscope is verified by experiments, and the measurement uncertainty is estimated. The online measurement results show that compared with the photoelectric autocollimator (measurement uncertainty is U = 0.07ʺ ( k = 2), the angle measurement error of the ring laser gyroscope goniometer in multi-axis turntable is ±0.4ʺ, and the measurement uncertainty is U = 0.36ʺ ( k = 2).
- Open Access
An Eccentricity Error Separation Method for Rotary Table Based on Phase Feature of Moiré Signal of Single Reading Head
In view of the limitations of the existing eccentricity error separation method of the rotary table, an eccentricity error separation method based on the phase feature of the moiré signal of a single reading head is proposed herein. A grating pair transmission model is established based on the analysis of the principle of the rotary table; thereby, the influence of eccentricity error on the phase feature of the moiré signal in the rotation course of the rotary table is clarified, and the corresponding model between the phase feature spectral components and the eccentricity error is established. The verification experiments of the proposed method are carried out based on the laboratory-made circuit system. After verifying the accuracy of the data acquisition of the laboratory-made circuit board, the verification experiments of the eccentricity error separation effect of the proposed method are carried out. The experimental data are compared with those of the traditional method, and the results show that the error between the two methods is 2.34 μm, while the relative error is 2.3%.
Open AccessAn Eccentricity Error Separation Method for Rotary Table Based on Phase Feature of Moiré Signal of Single Reading Head
In view of the limitations of the existing eccentricity error separation method of the rotary table, an eccentricity error separation method based on the phase feature of the moiré signal of a single reading head is proposed herein. A grating pair transmission model is established based on the analysis of the principle of the rotary table; thereby, the influence of eccentricity error on the phase feature of the moiré signal in the rotation course of the rotary table is clarified, and the corresponding model between the phase feature spectral components and the eccentricity error is established. The verification experiments of the proposed method are carried out based on the laboratory-made circuit system. After verifying the accuracy of the data acquisition of the laboratory-made circuit board, the verification experiments of the eccentricity error separation effect of the proposed method are carried out. The experimental data are compared with those of the traditional method, and the results show that the error between the two methods is 2.34 μm, while the relative error is 2.3%.
- Open Access
- 17 October 2023
- Published by MDPI AG in Preprints.org
An Eccentricity Error Separation Method for Rotary Table Based on Phase Feature of Moiré Signal of Single Reading Head
In view of the limitations of the existing eccentricity error separation method of the rotary table, an eccentricity error separation method based on the phase feature of the moiré signal of single reading head is proposed herein. A grating pair transmission model is established based on the analysis of the principle of the rotary table, thereby the influence of eccentricity error on the phase feature of the moiré signal in the rotation course of the rotary table is clarified, and the corresponding model between the phase feature spectral components and the eccentricity error is established. The verification experiments of the proposed method are carried out based on the laboratory-made circuit system. After verifying the accuracy of the data acquisition of the laboratory-made circuit board, the verification experiments of the eccentricity error separation effect of the proposed method are carried out. The experimental data are compared with those of the traditional method and the results show that the error between the two methods is 2.34μm and the relative error is 2.3%.
- 17 October 2023
- Published by MDPI AG in Preprints.org
Open AccessAn Eccentricity Error Separation Method for Rotary Table Based on Phase Feature of Moiré Signal of Single Reading Head
In view of the limitations of the existing eccentricity error separation method of the rotary table, an eccentricity error separation method based on the phase feature of the moiré signal of single reading head is proposed herein. A grating pair transmission model is established based on the analysis of the principle of the rotary table, thereby the influence of eccentricity error on the phase feature of the moiré signal in the rotation course of the rotary table is clarified, and the corresponding model between the phase feature spectral components and the eccentricity error is established. The verification experiments of the proposed method are carried out based on the laboratory-made circuit system. After verifying the accuracy of the data acquisition of the laboratory-made circuit board, the verification experiments of the eccentricity error separation effect of the proposed method are carried out. The experimental data are compared with those of the traditional method and the results show that the error between the two methods is 2.34μm and the relative error is 2.3%.
- 4 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-14
Flexible Extrinsic Parameter Calibration for Multicameras With Nonoverlapping Field of View
In many measurement applications using multicameras, there is often a nonoverlapping field of view (nFOV) between multicameras. It benefits greatly from having all of the cameras unified in a single coordinate frame by means of common spatial constraints. However, it is very difficult to establish common spatial constraints for accurate and quick calibration of the extrinsic parameters between multicameras in the case of long working distance, asymmetric working angle, or limited working space. To overcome these issues, we propose a flexible calibration method using a camera rig, which can be easily modeled as a hand–eye calibration problem and solved by only several sets of calibration images. To further improve the calibration accuracy, the camera intrinsic parameters, lens distortion coefficients, and extrinsic parameters are optimized simultaneously, similar to binocular calibration. However, this causes calculation instability of multiparameters. We extend the epipolar constraint to two images with an nFOV and add it into the optimization objective function together with the reprojection error, which ensures the basic consistency of intrinsic parameters before and after optimization, and reduce the fluctuation caused by the number of images involved in calibration. Experiments and application have proved that the proposed new methods are feasible and effective.
- 4 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-14
Flexible Extrinsic Parameter Calibration for Multicameras With Nonoverlapping Field of View
In many measurement applications using multicameras, there is often a nonoverlapping field of view (nFOV) between multicameras. It benefits greatly from having all of the cameras unified in a single coordinate frame by means of common spatial constraints. However, it is very difficult to establish common spatial constraints for accurate and quick calibration of the extrinsic parameters between multicameras in the case of long working distance, asymmetric working angle, or limited working space. To overcome these issues, we propose a flexible calibration method using a camera rig, which can be easily modeled as a hand–eye calibration problem and solved by only several sets of calibration images. To further improve the calibration accuracy, the camera intrinsic parameters, lens distortion coefficients, and extrinsic parameters are optimized simultaneously, similar to binocular calibration. However, this causes calculation instability of multiparameters. We extend the epipolar constraint to two images with an nFOV and add it into the optimization objective function together with the reprojection error, which ensures the basic consistency of intrinsic parameters before and after optimization, and reduce the fluctuation caused by the number of images involved in calibration. Experiments and application have proved that the proposed new methods are feasible and effective.
- 8 January 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (2) , 1396-1411
High-accuracy measurement system for the refractive index of air based on a simple double-beam interferometry
A measurement system based on a simple double-beam interferometry is built to realize the measurement of air refractive index with high accuracy. The basic principle of the system is that, through measuring the change of optical path difference caused by rapid and smooth vacuumization, measurement of refractive index of air is converted to length measurement. Error correction and signal processing are studied to ensure high-accuracy measurement of the refractive index of air. Three applicable methods are used in system. The system based on the methods realize the subdivision and counting of interference fringe by software with three-error correction, error compensation for the end-window plates’ thickness change caused by vacuumization, steady realization of high vacuum conditions. To verify the accuracy and reliability of the system, the measurement results are compared with that obtained from the method based on empirical Edlén’s formula. Analysis result shows that the expanded measurement uncertainty of the system is U = 5×10−9, with k = 2. The system can be used to compensate the laser wavelength error caused by the refractive index of air with high accuracy.
- 8 January 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (2) , 1396-1411
High-accuracy measurement system for the refractive index of air based on a simple double-beam interferometry
A measurement system based on a simple double-beam interferometry is built to realize the measurement of air refractive index with high accuracy. The basic principle of the system is that, through measuring the change of optical path difference caused by rapid and smooth vacuumization, measurement of refractive index of air is converted to length measurement. Error correction and signal processing are studied to ensure high-accuracy measurement of the refractive index of air. Three applicable methods are used in system. The system based on the methods realize the subdivision and counting of interference fringe by software with three-error correction, error compensation for the end-window plates’ thickness change caused by vacuumization, steady realization of high vacuum conditions. To verify the accuracy and reliability of the system, the measurement results are compared with that obtained from the method based on empirical Edlén’s formula. Analysis result shows that the expanded measurement uncertainty of the system is U = 5×10−9, with k = 2. The system can be used to compensate the laser wavelength error caused by the refractive index of air with high accuracy.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 74-80
Binocular initial location and extrinsic parameters real-time calculation for bionic eye system
A simple binocular visual equipment is designed in this paper, which is mainly composed by two CCD cameras and four stepping motors. Firstly, the two cameras' initial location is determined based on rough location by moving to the limiting position, and precise location by driving the image center aligning with fitted ellipse center. Then, the transformation matrix between coordinate systems of motion module end and the camera is calibrated with eye-in-hand calibration method, which adopts multi frame images and a method based on Levenberg-Marquardt iterative algorithm to improve its precision and robustness. Finally, the updating equations of transformation matrix between two camera's coordinate systems are deduced with high precision and real-time property to guarantee the binocular visual system's depth perception. The performance of the above methods is confirmed by comparative experiments.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 74-80
Binocular initial location and extrinsic parameters real-time calculation for bionic eye system
A simple binocular visual equipment is designed in this paper, which is mainly composed by two CCD cameras and four stepping motors. Firstly, the two cameras' initial location is determined based on rough location by moving to the limiting position, and precise location by driving the image center aligning with fitted ellipse center. Then, the transformation matrix between coordinate systems of motion module end and the camera is calibrated with eye-in-hand calibration method, which adopts multi frame images and a method based on Levenberg-Marquardt iterative algorithm to improve its precision and robustness. Finally, the updating equations of transformation matrix between two camera's coordinate systems are deduced with high precision and real-time property to guarantee the binocular visual system's depth perception. The performance of the above methods is confirmed by comparative experiments.