Precision calibration and systematic error reduction in the long trace profiler
Authors:
- 1 January 2000
- journal article
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 39 (1) , 304-310
Abstract
The long trace profiler (LTP) has become the instrument of choice for surface figure testing and slope error measurement of mirrors used for synchrotron radiation and x-ray astronomy optics. In order to achieve highly accurate measurements with the LTP, systematic errors need to be reduced by precise angle calibration and accurate focal plane position adjustment. A self-scanning method is presented to adjust the focal plane position of the detector with high precision by use of a pentaprism scanning technique. The focal plane position can be set to better than 0.25 mm for a 1250-mm-focal-length Fourier-transform lens using this technique. The use of a 0.03-arcsec-resolution theodolite combined with the sensitivity of the LTP detector system can be used to calibrate the angular linearity error very precisely. Some suggestions are introduced for reducing the system error. With these precision calibration techniques, accuracy in the measurement of figure and slope error on meter-long mirrors is now at a level of about 1 µrad rms over the whole testing range of the LTP.Keywords
This publication has 15 references indexed in Scilit:
- Mirror distortion measurements with an in-situ LTP1998
- Vertical scanning long trace profiler: a tool for metrology of x-ray mirrors1997
- Precise measuring method for detecting the in situ distortion profile of a high-heat-load mirror for synchrotron radiation by use of a pentaprism long trace profilerApplied Optics, 1997
- Penta-Prism Long Trace Profiler (PPLTP) for measurement of grazing incidence space optics1996
- Measurement of x‐ray telescope mirrors using a vertical scanning long trace profilerOptical Engineering, 1996
- The penta-prism LTP: A long-trace-profiler with stationary optical head and moving penta prisma)Review of Scientific Instruments, 1995
- In situ surface profiler for high heat load mirror measurementOptical Engineering, 1995
- Improved measurement accuracy in a long trace profiler: Compensation for laser pointing instabilityNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1994
- Using a straightness reference in obtaining more accurate surface profiles from a long trace profilerReview of Scientific Instruments, 1992
- Design Of A Long Trace Surface Profiler1987