Sliding behavior of zirconia porous implant surfaces against bone
- 19 September 2018
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 107 (4) , 1113-1121
Abstract
Different zirconia porous layers were produced on zirconia dense zirconia substrates by slip casting using powder with different mean sizes: 40 μm (Z40), 70 μm (Z70), and 100 μm (Z100). The dynamic and static coefficients of friction against bovine femoral bone, mimicking the implantation process, were conducted using a ball‐on‐flat reciprocating sliding tribometer under 3 N of normal load. Additionally, the porous layers were assessed with regard to their low temperature degradation (aging).Results revealed that the porous layers were able to keep their integrity during the sliding testes against bone, with no zirconia particles being transferred to the bone. Results did not show significant differences (p > 0.05) in kinetic and static COF values for Z40, Z70, Z100, and GRAD specimens, ranging from 0.53 to 0.77 and 0.65 to 0.90, respectively. The aging tests revealed that all surfaces were prone to low temperature degradation (~49% of monoclinic content after 18 h). In conclusion, the cohesive integrity of the layers and relatively high COF observed reveled that zirconia porous layers may be considered for replacing the current implant surfaces, and are expected to improve their primary stability. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1113–1121, 2019.Keywords
Funding Information
- Conselho Nacional de Desenvolvimento Científico e Tecnológico (PVE/CAPES/CNPq/407035/2013‐3)
- Fundação para a Ciência e a Tecnologia (NORTE‐01‐0145‐FEDER‐000018 ‐ HAMaBICo, UID/EEA/04436/2013, EXCL/EMS‐TEC/0460/2012)
This publication has 32 references indexed in Scilit:
- Microstructural and Wear Behavior Characterization of Porous Layers Produced by Pulsed Laser Irradiation in Glass-Ceramics SubstratesMaterials, 2013
- Low-temperature degradation in zirconia with a porous surfaceActa Biomaterialia, 2011
- Surface‐modified zirconia implants: tissue response in rabbitsClinical Oral Implants Research, 2009
- Osseointegration of zirconia implants compared with titanium: an in vivo studyHead & Face Medicine, 2008
- Low-Temperature Degradation of Zirconia and Implications for Biomedical ImplantsAnnual Review of Materials Research, 2007
- Artificial composite bone as a model of human trabecular bone: The implant–bone interfaceJournal of Biomechanics, 2007
- Loaded Custom‐Made Zirconia and Titanium Implants Show Similar Osseointegration: An Animal ExperimentJournal of Periodontology, 2004
- Influence of Porosity on Friction and Wear of Tetragonal Zirconia PolycrystalJournal of the American Ceramic Society, 1997
- Friction properties of the interface between porous‐surfaced metals and tibial cancellous boneJournal of Biomedical Materials Research, 1990
- Calibration Curve for Quantitative Analysis of the Monoclinic-Tetragonal ZrO2System by X-Ray DiffractionJournal of the American Ceramic Society, 1984