Telma A Dantas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Telma A Dantas has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Filipe Samuel Silva
CMEMS – Center for Microelectromechanical Systems, University of Minho, Guimarães, Portugal
9 shared publications - Mafalda M. Costa
Center for Micro-Electro Mechanical Systems (CMEMS-UMinho), University of Minho, Campus de Azurém, 4800-058 Guimarães, Portugal
3 shared publications Paula Vaz
Center for MicroElectroMechanical Systems, University of Minho, Porto, Portugal
3 shared publications- Bruno Henriques
Post-Graduation Program of Dentistry, Center for Education and Research on Dental Implants, Federal University of Santa Catarina, Florianópolis, Brazil
2 shared publications - Cristiano S. Abreu
Physics Department, Porto Superior Engineering Institute, ISEP, 4200-072 Porto, Portugal
2 shared publications - Georgina Miranda
CICECO, Aveiro Institute of Materials, University of Aveiro, 3810-193 Aveiro, Portugal
2 shared publications
Latest Publications
- Open Access
- 1 January 2023
- Published by Medknow in Journal of Dental Implants
- Vol. 13 (1) , 35-48
Subperiosteal dental implants: Past or future? A critical review on clinical trials/case reports and future directions
Subperiosteal implants were first introduced in 1942 in Sweden and were subsequently used worldwide for the treatment of mandibular and maxillary arches with advanced bone atrophy. However, due to the high complication rates and unsuccessful outcomes, this therapy fell in disuse. Advances in digital technology have led to a new interest in subperiosteal implants therapy and investigators are looking for innovative and effective techniques for dental rehabilitation. In this review, a critical analysis on the performance and characteristics of subperiosteal implants was carried out. Parameters such as materials and surface coatings, the design and manufacturing techniques, methods of implantation, complementary strategies and the main clinical outcomes were carefully assessed. Furthermore, a comparison with current dental implants and a proposal for an optimized solution are presented.
- 1 January 2023
- Published by Medknow in Journal of Dental Implants
- Vol. 13 (1) , 35-48
Open AccessSubperiosteal dental implants: Past or future? A critical review on clinical trials/case reports and future directions
Subperiosteal implants were first introduced in 1942 in Sweden and were subsequently used worldwide for the treatment of mandibular and maxillary arches with advanced bone atrophy. However, due to the high complication rates and unsuccessful outcomes, this therapy fell in disuse. Advances in digital technology have led to a new interest in subperiosteal implants therapy and investigators are looking for innovative and effective techniques for dental rehabilitation. In this review, a critical analysis on the performance and characteristics of subperiosteal implants was carried out. Parameters such as materials and surface coatings, the design and manufacturing techniques, methods of implantation, complementary strategies and the main clinical outcomes were carefully assessed. Furthermore, a comparison with current dental implants and a proposal for an optimized solution are presented.
- 1 July 2022
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 133, 105350
Customized root-analogue dental implants - Procedure and errors associated with image acquisition, treatment, and manufacturing technology in an experimental study on a cadaver dog mandible
- 1 July 2022
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 133, 105350
Customized root-analogue dental implants - Procedure and errors associated with image acquisition, treatment, and manufacturing technology in an experimental study on a cadaver dog mandible
- 1 November 2021
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 123, 104786
Bacteria co-culture adhesion on different texturized zirconia surfaces
- 1 November 2021
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 123, 104786
Bacteria co-culture adhesion on different texturized zirconia surfaces
- Open Access
Customized Root-Analogue Implants: A Review on Outcomes from Clinical Trials and Case Reports
(1) It is estimated that 10% of the world’s population will need a dental implant in their lifetime. Despite all the advances in the comprehension of dental implant designs, materials and techniques, traditional implants still have many limitations. Customized root-analogue implants are, therefore, gaining increased interest in dental rehabilitation and are expected to not only preserve more hard and soft tissues but also avoid a second surgery and improve patient overall satisfaction. In this sense, the aim of this review was to collect and analyse the clinical trials and case reports on customized root-analogue implants available in the literature; (2) This review was carried out according to the PRISMA Statement. An electronic database search was performed using five databases: PubMed, Google Scholar, Medline, Science Direct, and Scopus. The following keywords were used for gathering data: custom-made, dental implants, root-analogue, anatomical, customized and tooth-like; (3) 15 articles meeting the inclusion criteria—articles reporting clinical trials, case reports or animal studies and articles with root-analogue implants and articles with totally customized implant geometries—were selected for the qualitative synthesis. The design and manufacturing techniques, implant material and surface treatments were assessed and discussed; (4) The performance of some root-analogue implants with specific features (i.e., macro-retentions) was successful, with no signs of infection, periodontitis nor bleeding during the follow-up periods.
Open AccessCustomized Root-Analogue Implants: A Review on Outcomes from Clinical Trials and Case Reports
(1) It is estimated that 10% of the world’s population will need a dental implant in their lifetime. Despite all the advances in the comprehension of dental implant designs, materials and techniques, traditional implants still have many limitations. Customized root-analogue implants are, therefore, gaining increased interest in dental rehabilitation and are expected to not only preserve more hard and soft tissues but also avoid a second surgery and improve patient overall satisfaction. In this sense, the aim of this review was to collect and analyse the clinical trials and case reports on customized root-analogue implants available in the literature; (2) This review was carried out according to the PRISMA Statement. An electronic database search was performed using five databases: PubMed, Google Scholar, Medline, Science Direct, and Scopus. The following keywords were used for gathering data: custom-made, dental implants, root-analogue, anatomical, customized and tooth-like; (3) 15 articles meeting the inclusion criteria—articles reporting clinical trials, case reports or animal studies and articles with root-analogue implants and articles with totally customized implant geometries—were selected for the qualitative synthesis. The design and manufacturing techniques, implant material and surface treatments were assessed and discussed; (4) The performance of some root-analogue implants with specific features (i.e., macro-retentions) was successful, with no signs of infection, periodontitis nor bleeding during the follow-up periods.
- 1 July 2020
- Published by Elsevier in Ceramics International
- Vol. 46 (10) , 16328-16336
Design and optimization of zirconia functional surfaces for dental implants applications
- 1 July 2020
- Published by Elsevier in Ceramics International
- Vol. 46 (10) , 16328-16336
Design and optimization of zirconia functional surfaces for dental implants applications
- 1 December 2019
- Published by Elsevier in Transactions of Nonferrous Metals Society of China
- Vol. 29 (12) , 2523-2533
Corrosion behaviour of PEEK or β-TCP-impregnated Ti6Al4V SLM structures targeting biomedical applications
- 1 December 2019
- Published by Elsevier in Transactions of Nonferrous Metals Society of China
- Vol. 29 (12) , 2523-2533
Corrosion behaviour of PEEK or β-TCP-impregnated Ti6Al4V SLM structures targeting biomedical applications
- 19 September 2018
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 107 (4) , 1113-1121
Sliding behavior of zirconia porous implant surfaces against bone
Different zirconia porous layers were produced on zirconia dense zirconia substrates by slip casting using powder with different mean sizes: 40 μm (Z40), 70 μm (Z70), and 100 μm (Z100). The dynamic and static coefficients of friction against bovine femoral bone, mimicking the implantation process, were conducted using a ball‐on‐flat reciprocating sliding tribometer under 3 N of normal load. Additionally, the porous layers were assessed with regard to their low temperature degradation (aging).Results revealed that the porous layers were able to keep their integrity during the sliding testes against bone, with no zirconia particles being transferred to the bone. Results did not show significant differences (p > 0.05) in kinetic and static COF values for Z40, Z70, Z100, and GRAD specimens, ranging from 0.53 to 0.77 and 0.65 to 0.90, respectively. The aging tests revealed that all surfaces were prone to low temperature degradation (~49% of monoclinic content after 18 h). In conclusion, the cohesive integrity of the layers and relatively high COF observed reveled that zirconia porous layers may be considered for replacing the current implant surfaces, and are expected to improve their primary stability. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1113–1121, 2019.
- 19 September 2018
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 107 (4) , 1113-1121
Sliding behavior of zirconia porous implant surfaces against bone
Different zirconia porous layers were produced on zirconia dense zirconia substrates by slip casting using powder with different mean sizes: 40 μm (Z40), 70 μm (Z70), and 100 μm (Z100). The dynamic and static coefficients of friction against bovine femoral bone, mimicking the implantation process, were conducted using a ball‐on‐flat reciprocating sliding tribometer under 3 N of normal load. Additionally, the porous layers were assessed with regard to their low temperature degradation (aging).Results revealed that the porous layers were able to keep their integrity during the sliding testes against bone, with no zirconia particles being transferred to the bone. Results did not show significant differences (p > 0.05) in kinetic and static COF values for Z40, Z70, Z100, and GRAD specimens, ranging from 0.53 to 0.77 and 0.65 to 0.90, respectively. The aging tests revealed that all surfaces were prone to low temperature degradation (~49% of monoclinic content after 18 h). In conclusion, the cohesive integrity of the layers and relatively high COF observed reveled that zirconia porous layers may be considered for replacing the current implant surfaces, and are expected to improve their primary stability. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1113–1121, 2019.
- 1 September 2018
- Published by Elsevier in International Journal of Refractory Metals and Hard Materials
- Vol. 75, 85-93
Wear behaviour of tetragonal zirconia polycrystal with a porous surface
- 1 September 2018
- Published by Elsevier in International Journal of Refractory Metals and Hard Materials
- Vol. 75, 85-93
Wear behaviour of tetragonal zirconia polycrystal with a porous surface
- Open Access
- 1 January 2018
- Published by Elsevier in Procedia CIRP
- Vol. 70, 278-283
Mechanical Design of a Standing Frame adapted for Children with mental deficiency
- 1 January 2018
- Published by Elsevier in Procedia CIRP
- Vol. 70, 278-283
Open AccessMechanical Design of a Standing Frame adapted for Children with mental deficiency