Background: This study aimed to compare clinical and radiographic outcomes for a new tibial component (Attune S +) and the previous design (Attune S) in total knee arthroplasty (TKA) patients using ATTUNE® posterior stabilized (PS) prosthesis and also assessed related factors for the development of tibial radiolucent line(RLL). Methods: This retrospective study included 362 knees (179 Attune S, 183 Attune S +) with an average 4 years (range, 2–8) follow-up. Clinical outcomes, radiologic parameters and the incidence of RLL around the tibial component were compared through the serial assessment. For the subgroup analysis, radiologic parameters were compared between patients with and without RLL. Results: There was no significant difference in terms of clinical outcomes and radiologic parameters between two designs. The incidence of RLL was not different through the serial follow-up (P > 0.05). In the subgroup analysis, the preoperative medial proximal tibial angle (83.7° versus 85.0°, P = 0.01) was smaller and preoperative hip-knee-ankle angle (169.1° versus 171.8°, P = 0.01) has more varus in the group with RLL than those without. Conclusions: The clinical and radiologic outcomes including the incidence of tibial RLL between new design and predecessor were not significantly different at average 4 years follow-up. The development of tibial RLL was associated with preoperative varus deformity of tibia and lower limb alignment.Keywords
This publication has 29 references indexed in Scilit:
- Internal fixation of intracapsular fractures of the hip using a dynamic locking plateThe Bone & Joint Journal, 2013
- Osteolysis around total knee arthroplasty: A review of pathogenetic mechanismsActa Biomaterialia, 2013
- Preoperative Malalignment Increases Risk of Failure After Total Knee ArthroplastyJournal of Bone and Joint Surgery, 2013
- Metal block augmentation for bone defects of the medial tibia during primary total knee arthroplastyJournal of Orthopaedic Surgery and Research, 2013
- Complications of Total Knee Arthroplasty: Standardized List and Definitions of The Knee SocietyClinical Orthopaedics and Related Research, 2013
- Modified gap‐balancing technique in total knee arthroplasty: evaluation of the post‐operative coronal laxityKnee Surgery, Sports Traumatology, Arthroscopy, 2009
- Reliability of detecting prosthesis/cement interface radiolucencies in total hip arthroplastyJournal of Orthopaedic Research, 2002
- The natural history of tibial radiolucent lines in a proximally cemented stemmed total knee arthroplastyThe Journal of Arthroplasty, 1999
- Radiolucency at the bone-cement interface in total knee replacement. The effects of bone-surface preparation and cement technique.Journal of Bone and Joint Surgery, 1994
- The Knee Society Total Knee Arthroplasty Roentgenographic Evaluation and Scoring SystemClinical Orthopaedics and Related Research, 1989