Radiolucency at the bone-cement interface in total knee replacement. The effects of bone-surface preparation and cement technique.
Authors:
- S A HerbstSHS A Herbst
- E M KeatingEKE M Keating
- P M FarisPFP M Faris
- 1 January 1994
- journal article
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 76 (1) , 60-65
Abstract
Tion of the bone surfaces with a syringe and manual packing of the bone cement. Group 2 (sixty-one knees) had high-volume, high-pressure lavage of the bone surfaces and manual packing of the cement. Group 3 (147 knees) had high-volume, high-pressure lavage and pressure injection of low-viscosity methylmethacrylate cement. Radiolucency was evaluated at each follow-up interval, and the findings were subjected to chi-square analysis and Kaplan-Meier survival analysis. Chi-square analysis of the data at one and three years indicated a significantly higher frequency of lines at the bone-cement interface in the femur and tibia in Group-1 knees compared with those in Groups 2 and 3. The survival curves showed increasing rates of radiolucency adjacent to the tibial components of the knees that had been prepared with lavage that was not high-volume and high-pressure and that had been prepared with finger-packing of cement (Group 1). This may partially explain the clinical problem of loosening of tibial components despite acceptable alignment. This study demonstrates that proper preparation of the cancellous bone and pressurization of the cement reduce the initial occurrence of a radiolucent line, which may have a positive effect on the ultimate failure of at least the tibial component. Three hundred and sixty-three knees (221 patients) that had been treated with total arthroplasty between 1975 and 1985 were divided into three groups on the basis of the preparation of the surface of the bone and the technique of the cement application. Group 1 (155 knees) was treated with irrigation of the bone surfaces with a syringe and manual packing of the bone cement. Group 2 (sixty-one knees) had high-volume, high-pressure lavage of the bone surfaces and manual packing of the cement. Group 3 (147 knees) had high-volume, high-pressure lavage and pressure injection of low-viscosity methylmethacrylate cement. Radiolucency was evaluated at each follow-up interval, and the findings were subjected to chi-square analysis and Kaplan-Meier survival analysis. Chi-square analysis of the data at one and three years indicated a significantly higher frequency of lines at the bone-cement interface in the femur and tibia in Group-1 knees compared with those in Groups 2 and 3. The survival curves showed increasing rates of radiolucency adjacent to the tibial components of the knees that had been prepared with lavage that was not high-volume and high-pressure and that had been prepared with finger-packing of cement (Group 1). This may partially explain the clinical problem of loosening of tibial components despite acceptable alignment. This study demonstrates that proper preparation of the cancellous bone and pressurization of the cement reduce the initial occurrence of a radiolucent line, which may have a positive effect on the ultimate failure of at least the tibial component. Copyright © 1994 by The Journal of Bone and Joint Surgery, Incorporated...Keywords
This publication has 9 references indexed in Scilit:
- High-volume, high-pressure pulsatile lavage during cemented arthroplasty.Journal of Bone and Joint Surgery, 1989
- The cemented kinematic-II and the non-cemented porous-coated anatomic prostheses for total knee replacement. A prospective evaluation.Journal of Bone and Joint Surgery, 1988
- Long-term Results after Total Condylar Knee ArthroplastyClinical Orthopaedics and Related Research, 1987
- Biplane radiographic measurements of reversible displacement (including clinical loosening) and migration of total joint replacements.Journal of Bone and Joint Surgery, 1983
- Mechanical strength of poly(methyl methacrylate) cement‐human bone interfacesJournal of Biomedical Materials Research, 1983
- The role of lavage in preventing hemodynamic and blood-gas changes during cemented arthroplasty.Journal of Bone and Joint Surgery, 1983
- Effect of cement pressure and bone strength on polymethylmethacrylate fixationJournal of Orthopaedic Research, 1983
- Strength of the Cement-Bone InterfaceClinical Orthopaedics and Related Research, 1982
- Influence of positioning of prosthesis in total knee replacementJournal of Bone and Joint Surgery, 1977