Abstract
Purpose: To compare the relative cerebral blood flow (CBF) obtained by pseudo‐continuous arterial spin labeling sequence incorporated with volumetric fast spin‐echo readout (3D‐PCASL) with those by gradient‐echo (GE) and spin‐echo (SE) dynamic susceptibility contrast (DSC) MRI.Materials and Methods: Thirty patients with various neurological diseases participated in this study. In addition to 3D‐PCASL, 15 patients received GE‐DSC and the others received SE‐DSC imaging on a 3 Tesla scanner. A cortical gray matter (GM) to white matter (WM) and a thalamus (TM) to WM CBF ratio were determined from each perfusion scan. In addition, histograms of relative CBF distributions were obtained from each method for comparison.Results: Significant correlations of CBF ratios were found between 3D‐PCASL and the two DSC methods (P < 0.05). The 3D‐PCASL resulted in GM/WM CBF ratios similar to SE‐DSC but significantly smaller than GE‐DSC (P = 2.3 × 10−7). TM/WM CBF ratio obtained by 3D‐PCASL was significantly smaller than those by GE‐ and SE‐DSC (P = 4.1 × 10−7 and 1.2 × 10−6, respectively). The histogram of relative CBF maps obtained from SE‐DSC, after applied spatial smoothing, agreed well with that from 3D‐PCASL.Conclusion: This study suggested that perfusion images obtained from 3D‐PCASL exhibited significant correlations with DSC‐MRI, with greater microvascular weighting like SE‐DSC. J. Magn. Reson. Imaging 2014;39:427–433. © 2013 Wiley Periodicals, Inc.Keywords
This publication has 28 references indexed in Scilit:
- Whole-Brain Arterial Spin Labeling Perfusion MRI in Patients With Acute StrokeStroke, 2012
- The Value of Arterial Spin-Labeled Perfusion Imaging in Acute Ischemic StrokeStroke, 2012
- Pseudocontinuous Arterial Spin Labeling Quantifies Relative Cerebral Blood Flow in Acute StrokeStroke, 2012
- Comparison of relative cerebral blood flow maps using pseudo‐continuous arterial spin labeling and single photon emission computed tomographyNMR in Biomedicine, 2011
- Pseudocontinuous arterial spin labeling perfusion magnetic resonance imaging—A normative study of reproducibility in the human brainNeuroImage, 2011
- Perfusion MRI of brain tumours: a comparative study of pseudo-continuous arterial spin labelling and dynamic susceptibility contrast imagingNeuroradiology, 2009
- Continuous flow‐driven inversion for arterial spin labeling using pulsed radio frequency and gradient fieldsMagnetic Resonance in Medicine, 2008
- Assessment of Irradiated Brain Metastases by Means of Arterial Spin-Labeling and Dynamic Susceptibility-Weighted Contrast-Enhanced Perfusion MRIInvestigative Radiology, 2004
- Comparison of Arterial Spin-Labeling Techniques and Dynamic Susceptibility-Weighted Contrast-Enhanced MRI in Perfusion Imaging of Normal Brain TissueInvestigative Radiology, 2003
- High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysisMagnetic Resonance in Medicine, 1996