HLHo‐Ling Liu

Ho‐Ling Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ho‐Ling Liu has a total of 64 co-authors. Here are the top co-authors by number of shared publications:

  • Changwei Wesley Wu

    Research Center of Sleep Medicine, Taipei Medical University Hospital, Taipei, Taiwan

    5 shared publications
  • Kun‐Eng Lim

    Department of Medical Imaging, Buddhist Tzu Chi General Hospital, Taipei, Taiwan

    4 shared publications
  • Yuan‐Yu Hsu

    Department of Medical Imaging, Buddhist Tzu Chi General Hospital, Taipei, Taiwan

    4 shared publications
  • Wan‐Chun Kuan

    Department of Medical Physics Koo Foundation Sun Yat‐Sen Cancer Center Taipei City Taiwan

    3 shared publications
  • Yau‐Yau Wai

    Department of Medical Imaging and Radiological Sciences Chang Gung University Taoyuan Taiwan

    3 shared publications
  • Yung‐Liang Wan

    Department of Medical Imaging and Radiological Sciences Chang Gung University Taoyuan Taiwan

    3 shared publications

Latest Publications

  • Open Access

    Heterogeneous Cerebral Vasoreactivity Dynamics in Patients with Carotid Stenosis

    by Ting-Yu Chang, Wan-Chun Kuan, Kuo-Lun Huang, Chien-Hung Chang, Yeu-Jhy Chang, Ho-Fai Wong, Tsong-Hai Lee, Ho-Ling Liu

    Cerebral vasoreactivity (CVR) can be assessed by functional MRI (fMRI) using hypercapnia challenges. In normal subjects, studies have shown temporal variability of CVR blood oxygenation level-dependent responses among different brain regions. In the current study, we analyzed the variability of BOLD CVR dynamics by fMRI with a breath-holding task in 17 subjects with unilateral carotid stenosis before they received carotid stenting. Great heterogeneity of CVR dynamics was observed when comparing BOLD responses between ipsilateral and contralateral hemispheres in each patient, especially in middle cerebral artery (MCA) territories. While some subjects (n=12) had similar CVR responses between either hemisphere, the others (n=5) had a poorly correlated pattern of BOLD changes between ipsilateral and contralateral hemispheres. In the latter group, defined as impaired CVR, post-stenting perfusion tended to be more significantly increased. Our data provides the first observation of divergent temporal BOLD responses during breath holding in patients with carotid stenosis. The development of collateral circulation and the derangement of cerebral hemodynamics can be detected through this novel analysis of the different patterns of BOLD changes. The results also help in prediction of robust increase of perfusion or hyperperfusion after carotid stenting.


  • Variations in BOLD response latency estimated from event‐related fMRI at 3T: Comparisons between gradient‐echo and Spin‐echo

    by Mei‐Yu Yeh, Changwei W. Wu, Wan‐Chun Kuan, Pei‐Shan Wei, Yung‐Liang Wan, Yau‐Yau Wai, Hsu‐Huei Weng, Ho‐Ling Liu


  • Effects of Quality Assurance Regulatory Enforcement on Performance of Mammography Systems: Evidence From Large-Scale Surveys in Taiwan

    by Yi-Shuan Hwang, Hui-Yu Tsai, Chien-Chuan Chen, Pei-Kwei Tsay, Huay-Ben Pan, Giu-Cheng Hsu, Jen-Hsuan Lin, Chen-Shou Chui, Yung-Liang Wan, Ho-Ling Liu

    OBJECTIVE. The Standards for Medical Exposure Quality Assurance in mammography systems were enacted on July 1, 2008, in Taiwan. This study aimed to evaluate the trends in performance of mammography units before and after the regulation started on the basis of annual on-site surveys from 2008 to 2010. MATERIALS AND METHODS. On-site measurements were conducted on 215, 205, and 209 mammography units in 2008, 2009, and 2010, respectively, which accounted for more than 95% of all units in Taiwan. Phantom image quality, average glandular dose (AGD), and half-value layer were evaluated on all systems. Processor conditions, compression conditions, radiation output, and computed radiography exposure indicators were assessed on units participating in mammography screening in 2008 and on all units in the later years. Evaluations of maximum compression force and automatic exposure control reproducibility were added into the protocol from 2009 onward. RESULTS. Mean phantom scores were improved significantly from 2008 to 2009 (11.63 ± 1.30 vs 12.31 ± 0.94, p < 0.05) and remained stable for 2010 (12.35 ± 0.87). Mean AGDs were 1.48 ± 0.47, 1.38 ± 0.41, and 1.37 ± 0.42 mGy over the 3 years, with a significant reduction from 2008 to 2009 (p < 0.05). For film-screen mammography systems, variations of sensitometric curves were greatly reduced in 2009 and 2010 when compared with 2008. Passing rates were increased after the regulation took effect in almost all aspects. CONCLUSION. Results from large-scale on-site surveys showed an overall improvement in performance after quality assurance in mammography was enforced in Taiwan.


  • Resting-State Functional Magnetic Resonance Imaging Analysis with Seed Definition Constrained by Regional Homogeneity

    by Feng-Xian Yan, Changwei W. Wu, Shih-Yu Cheng, Kun-Eng Lim, Yuan-Yu Hsu, Ho-Ling Liu

    Researchers have recently focused their attention on the intrinsic functional connectivity (FC) in the brain using resting-state functional magnetic resonance imaging. Seed-based correlation analysis (SCAC), which correlates a predefined seed region with other voxels in the brain, is a common index for FC. However, definition of seed sizes and locations was ambiguous in previous studies and this may lead to spurious results for people with a unique functional anatomy. To address this issue, this study proposes a novel method (SCAReHo) that provides a data-driven seed selection (including sizes and locations) method by incorporating regional homogeneity (ReHo) in the SCAC method. The disparities between SCAC and SCAReHo methods among 12 healthy participants were evaluated in the FC of default mode network (DMN), task-positive network (TPN), and amygdala network. The SCAReHo method bypasses the seed-selection ambiguity and enhances the sensitivity in detecting FC of the DMN, TPN, and amygdala network. This study suggests that the SCAReHo method improves the sensitivity of FC analysis and reduces the uncertainty of seed selection. Thus, this method may be particularly useful for psychiatric and neurological investigations.


  • Comparison of three‐dimensional pseudo‐continuous arterial spin labeling perfusion imaging with gradient‐echo and spin‐echo dynamic susceptibility contrast MRI

    by Alex M. Wong, Feng‐Xian Yan, Ho‐Ling Liu

    Purpose: To compare the relative cerebral blood flow (CBF) obtained by pseudo‐continuous arterial spin labeling sequence incorporated with volumetric fast spin‐echo readout (3D‐PCASL) with those by gradient‐echo (GE) and spin‐echo (SE) dynamic susceptibility contrast (DSC) MRI.Materials and Methods: Thirty patients with various neurological diseases participated in this study. In addition to 3D‐PCASL, 15 patients received GE‐DSC and the others received SE‐DSC imaging on a 3 Tesla scanner. A cortical gray matter (GM) to white matter (WM) and a thalamus (TM) to WM CBF ratio were determined from each perfusion scan. In addition, histograms of relative CBF distributions were obtained from each method for comparison.Results: Significant correlations of CBF ratios were found between 3D‐PCASL and the two DSC methods (P < 0.05). The 3D‐PCASL resulted in GM/WM CBF ratios similar to SE‐DSC but significantly smaller than GE‐DSC (P = 2.3 × 10−7). TM/WM CBF ratio obtained by 3D‐PCASL was significantly smaller than those by GE‐ and SE‐DSC (P = 4.1 × 10−7 and 1.2 × 10−6, respectively). The histogram of relative CBF maps obtained from SE‐DSC, after applied spatial smoothing, agreed well with that from 3D‐PCASL.Conclusion: This study suggested that perfusion images obtained from 3D‐PCASL exhibited significant correlations with DSC‐MRI, with greater microvascular weighting like SE‐DSC. J. Magn. Reson. Imaging 2014;39:427–433. © 2013 Wiley Periodicals, Inc.


  • Open Access

    Vascular space occupancy MRI during breathholding at 3 tesla

    by Yuan‐Yu Hsu, Wen‐Cheng Chu, Kun‐Eng Lim, Ho‐Ling Liu

    Purpose: To evaluate the vasodilatory response of normal human brain and meningiomas under repeated breathholding challenges using vascular space occupancy (VASO) MRI at 3 Tesla (T). Materials and Methods: Five normal volunteers and five patients with meningiomas were recruited for this study. For the normal group, VASO MRI during repeated breathholds of different duration (5 to 30 s) was acquired. Patients performed a 15-s breathhold paradigm for VASO MRI. The maximum signal change and full-width at half-maximum (FWHM) were determined by curve fitting. Results: Significant VASO signal decreases in the gray matter could be detected for a breathhold period as short as 5 s. The fractional activation volume vs. breathhold duration reached a plateau around 34.21 ± 3.39% at 15 s. In the patient group, there were significant VASO signal decreases in normal gray matters and also in small areas of three large-sized meningiomas. Conclusion: The 3T VASO MRI detected significant signal decreases in the gray matter, but not in the white matter, during short periods of breathholding. The fractional activation volume reached the plateau at 15-s breathhold, which is recommended for clinical application. J. Magn. Reson. Imaging 2012;36:1179–1185.


  • In vivo correlation between semi‐quantitative hemodynamic parameters and Ktrans derived from DCE‐MRI of brain tumors

    by Chen Chih‐Feng, Hsu Ling‐Wei, Lui Chun‐Chung, Lee Chen‐Chang, Weng Hsu‐Huei, Tsai Yuan‐Hsiung, Liu Ho‐Ling

    Dynamic contrast‐enhanced (DCE) magnetic resonance imaging (MRI) has become more and more widely applied in cancer diagnosis and treatment follow‐up. Without complicated calculation, a semiquantitative parameter – modified initial area under the curve (mIAUCc) – was proposed for better correlation with volume transfer constant (Ktrans) by computer simulation. In this study, we aim to further investigate the correlation between mIAUCc and Ktrans in clinical. A total of 10 patients with brain tumors participated in this study and images were acquired by using a 3‐Tesla clinical MR scanner. The results showed that mIAUCc was highly correlated with Ktrans with the correlation coefficient of 0.913. Although the ideals of Ktrans and mIAUCc are different, mIAUCc does the trick for brain tumors evaluations in DCE‐MRI. It reveals that mIAUCc could be an alternative for physiological condition evaluation in DCE‐MRI. © 2012 Wiley Periodicals, Inc. Int J Imaging Syst Technol, 22, 132–136, 2012


  • Breathhold‐regulated blood oxygenation level‐dependent (BOLD) MRI of human brain at 3 tesla

    by Yuan‐Yu Hsu, Wan‐Chun Kuan, Kun‐Eng Lim, Ho‐Ling Liu

    Purpose: To investigate the cerebrovascular response to repeated breathhold challenges using blood oxygenation level‐dependent (BOLD) MRI at 3T and compare the results with previous data at 1.5T.Materials and Methods: Six normal volunteers and six patients with brain tumors were recruited for this 3T study. For the normal group, BOLD MRI during repeated breathholds of different durations (five to 30 seconds) were acquired. Maximum signal change, full‐width at half‐maximum (FWHM) and onset time (defined as the time to the first half‐maximum) were determined by curve fitting. The fractional activation volume was also calculated. Patients performed a 10‐ or 15‐second breathhold paradigm according to individual capability.Results: Significant BOLD signal increases in the gray matter for a breathhold period as short as 5 seconds at 3T, instead of 10 seconds at 1.5T. The fractional activation volume vs. breathhold duration reached a plateau of 49.54 ± 7.26% at 15 seconds at 3T, which was higher and shorter than that at 1.5T. The maximum signal changes were significantly larger (a 69% increase) at 3T than at 1.5T. In the patient group, there were BOLD signal increases in gray matter but not in tumor bulk or perifocal edema, which agreed with the results previously found at 1.5T.Conclusion: BOLD MRI at 3T is more sensitive for detecting breathhold‐regulated signal changes than at 1.5T, which allows a shorter and more feasible breathhold paradigm for clinical applications in patients with brain tumors. J. Magn. Reson. Imaging 2010;31:78–84.


  • Study of onset time-shift and injection duration in DCE-MRI: a comparison of a reference region model with the general kinetic model

    by Ing-Tsung Hsiao, Yen-Peng Liao, Ho-Ling Liu

    In dynamic contrast‐enhanced MR imaging (DCE‐MRI), sampling of the arterial input function (AIF) is required for analysis using the general kinetic model (GKM). Alternatively, the recently proposed reference region model (RRM) may be employed to avoid the need of acquiring the AIF. This study aimed to evaluate the influence of the AIF onset‐time shift and the injection duration, under various sampling intervals, on physiological parameter estimation in DCE‐MRI using the GKM, and to compare the performance between GKM and RRM. Computer simulations were performed to assess the mean error (ME) and coefficient of variation (CoV) of Ktrans,TOI and ve,TOI from shifted and dispersed AIF with temporal resolution of 1, 5 and 10 s. With 5‐s sampling, the maximal ME of Ktrans,TOI was roughly 22% for the GKM and 0.5% for the RRM. With 10‐s sampling, they increased to around 28% and 0.7%, respectively. The maximal MEs of ve,TOI for all cases were under 5%. However, owing to the lower SNR in the reference region, the CoV obtained by the RRM were all higher than those by the GKM. The results suggested that with compromised temporal resolution, the RRM was relatively less sensitive to the AIF onset‐time shift and the injection duration compared with the GKM. Copyright © 2009 John Wiley & Sons, Ltd.


  • Open Access

    Vessel size imaging using dual contrast agent injections

    by Yuan‐Yu Hsu, Wei‐Shan Yang, Kun‐Eng Lim, Ho‐Ling Liu

    Purpose: To investigate the feasibility of a vessel size imaging (VSI) technique with separate contrast agent injections for evaluation of the vessel caliber in normal tissues and in brain tumors.Materials and Methods: Computer simulation was first performed to assess the potential errors in the estimation of vessel caliber that could result from time shifts between the dual contrast agent injections. Eight patients (four female, four male, 37–77 years old) with brain tumors (three high‐grade gliomas, two low‐grade gliomas, and three meningiomas) were recruited for clinical study. Dynamic susceptibility contrast magnetic resonance imaging (MRI) using gradient echo (GE) and spin echo (SE) echo‐planar imaging sequences were performed separately with a 10‐minute interval on a 3.0T scanner. Vessel caliber maps were calculated and analyzed in regions of interest at cortical gray matter (GM), thalamus, white matter (WM), and tumors.Results: From the computer simulation, the error of vessel caliber measurement was less than 8% when the difference between the time‐to‐peak of the GE and the SE studies was 1.5 seconds, and reduced to within 5% when the difference was 1 second. From the patient datasets of a 64 × 64 matrix, the estimated vessel calibers were 37.4 ± 12.9 μm for cortical gray matter, 20.7 ± 8.8 μm for thalamus, and 15.0 ± 5.1 μm for white matter, comparable to results in the literature. Two patients had a VSI with 128 × 128 matrix and showed similar results in vessel calibers of normal tissues. All the tumors had larger mean vessel diameter than normal‐appearing tissues. The difference in vascular size between normal tissue and tumor was demonstrated clearly in both the VSIs of regular and high spatial resolution.Conclusion: This study suggests that VSI with a dual injection method is a feasible technique for estimating microvascular calibers of normal tissues and brain tumors in clinical scanners. J. Magn. Reson. Imaging 2009;30:1078–1084.