Accuracy of placement of pedicle screws in the thoracolumbar spine of dogs with spinal deformities with three‐dimensionally printed patient‐specific drill guides
- 16 October 2019
- journal article
- research article
- Published by Wiley in Veterinary Surgery
- Vol. 49 (2) , 347-353
Abstract
Objective: To determine the accuracy of pedicle screw placement in the thoracic spine of dogs with spinal deformities with three‐dimensionally (3D) printed patient‐specific drill guides.Study design: Retrospective study.Sample population: Six dogs in which sixty pedicle screws were placed in the thoracolumbar spine.Methods: Medical records were searched between June 2017 and June 2018 for dogs with clinical signs associated with a thoracolumbar vertebral malformation. Inclusion criteria included MRI and computed tomography (CT) data that were used to create 3D printed patient‐specific drill guides. All dogs were stabilized dorsally with guided bicortical pedicle screws and polymethylmethacrylate. Accuracy of screw placement was assessed by immediately postoperative CT according to a modified Zdichavsky classification.Results: Five pugs and one French bulldog met the inclusion criteria. Sixty bicortical pedicle screws were placed; 96.7% were graded as I (optimal placement), and 3.3% were classified as IIa (partial penetration of the medial pedicle wall) according to a modified Zdichavsky classification.Conclusion: Three‐dimensionally printed patient‐specific drill guides allowed safe and accurate placement of pedicle screws in the thoracolumbar spine in dogs with vertebral malformation.Clinical significance: Three‐dimensionally printed patient‐specific drill guides are a safe and effective method of placing pedicle screws in dogs with thoracolumbar vertebral malformations.Keywords
This publication has 25 references indexed in Scilit:
- Accuracy of Conventional Radiography and Computed Tomography in Predicting Implant Position in Relation to the Vertebral Canal in DogsVeterinary Surgery, 2010
- Surgical treatment of a hemivertebra by partial ventral corpectomy and fusion in a Labrador puppyVeterinary and Comparative Orthopaedics and Traumatology, 2010
- Evaluation of thoracic pedicle screw placement in adolescent idiopathic scoliosisEuropean Spine Journal, 2009
- Accuracy of thoracic pedicle screw placement in scoliosis using the ideal pedicle entry point during the freehand techniqueInternational Orthopaedics, 2008
- Vertebral Stabilization Using Positively Threaded Profile Pins and Polymethylmethacrylate, with or Without Laminectomy, for Spinal Canal Stenosis and Vertebral Instability Caused by Congenital Thoracic Vertebral AnomaliesVeterinary Surgery, 2007
- Imaging findings and surgical treatment of hemivertebrae in three dogsJournal of the American Veterinary Medical Association, 2007
- Matrix metalloproteinase-9 activity in the cerebrospinal fluid and serum of dogs with acute spinal cord trauma from intervertebral disk diseaseAmerican Journal of Veterinary Research, 2006
- Thoracic Pedicle Screw Fixation in Spinal DeformitiesSpine, 2001
- Pedicle Screw Instrumentation of the Thoracic Spine in Idiopathic ScoliosisSpine, 1997
- Congenital Anomalies of the Vertebral Column of the Dog: A Study of the Incidence and Significance Based on a Radiographic and Morphologic Study1Veterinary Radiology, 1968