BOBill Oxley

Bill Oxley

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bill Oxley has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Lumbosacral intervertebral disk extrusions in 13 dogs

    by Luca Bresciani, Raquel Trevail, Stephen Clarke, Rodrigo Gutierrez‐Quintana, Sebastien Behr, Kali Lazzerini, Josep Brocal, Bill Oxley, Jonathan Pink, Roberto José‐López

    Objective: To describe the clinical presentation, magnetic resonance imaging (MRI) findings, and outcome of dogs treated surgically for lumbosacral intervertebral disk extrusion (IVDE).Study Design: Retrospective study.Animals: Thirteen dogs.Methods: Records and MRI studies of dogs with intraoperatively confirmed lumbosacral IVDE were reviewed. MRI features of thoracolumbar IVDE were applied to all cases. Postoperative outcome was subjectively assessed as excellent, good, or poor.Results: All dogs had an acute or subacute onset of lumbosacral pain and nerve root signature. Seven dogs had neurological deficits. MRI revealed lateralized herniated disk material and partial to complete disk degeneration in all cases; the extradural material extended cranial and/or caudally from the disk space in 10 cases. All dogs underwent L7‐S1 dorsal laminectomy and removal of extruded disk material. In six dogs, surgery was complicated by inflammatory changes, including one case of epidural steatitis. On reexamination 4–6 weeks postsurgery, outcome was judged as excellent in 11 dogs and poor in the remaining 2 due to contralateral nerve root signature in one case and nonambulatory paraparesis and urinary incontinence in the case with steatitis.Conclusion: Lumbosacral IVDE in dogs was characterized by acute/subacute onset of lumbosacral pain and nerve root signature and lateralized and often dispersed extradural material over a degenerated L7‐S1 intervertebral disk on MRI. Early decompressive dorsal laminectomy generally resulted in excellent clinical outcome.Clinical Significance: Observation of these clinical and imaging features in dogs should prompt clinical suspicion of lumbosacral IVDE.


  • Accuracy of Placement of Pedicle Screws in the Lumbosacral Region of Dogs Using 3D-Printed Patient-Specific Drill Guides

    by Cristina Toni, Bill Oxley, Stephen Clarke, Sebastien Behr

    Objective The aim of this study was to report the accuracy of pedicle screw placement using three-dimensional (3D)-printed, patient-specific drill guides in the lumbosacral region of dogs. Study Design This was a retrospective study. Thirty-two pedicle screws were placed in five dogs. Medical records were reviewed between November 2015 and November 2018 for dogs showing clinical signs associated with cauda equina syndrome. Inclusion criteria included preoperative magnetic resonance imaging, pre- and postoperative computed tomography (CT) and dorsal stabilization, with pedicle screws placed using 3D-printed, patient-specific drill guides and polymethylmethacrylate. Screw placement was evaluated for medial or lateral breaching on postoperative CT. Results Five dogs met the inclusion criteria. Four had degenerative lumbosacral stenosis and one had discospondylitis. All dogs had failed medical management prior to surgery. Of 32 bicortical pedicle screws placed, 30 were fully contained inside the pedicle and 2 were partially breaching the vertebral canal (less than one-third of the screw diameter). Postoperative CT revealed good alignment of L7-S1 in all planes. Conclusion This technique enabled an accurate and safe placement of pedicle screws in the lumbosacral region of dogs with lumbosacral disease. Three-dimensional, printed patient-specific drill guides are a safe and effective method of placing pedicle screws in dogs with lumbosacral disease.


  • Long‐term outcomes after pantarsal arthrodesis with medial plate fixation without external coaptation in 30 dogs

    by Simone Anesi, Stephen Clarke, Toby Gemmill, Bill Oxley, Jonathan Pink, Kinley Smith, Scott Rutherford

    Objective: To report long‐term outcomes of dogs treated with pantarsal arthrodesis (PTA) with medial plate fixation without external coaptation.Study design: Retrospective case series.Animals: Client‐owned dogs (n = 30).Methods: Medical records of dogs that had undergone a PTA with a medially applied plate without adjunctive rigid external coaptation were reviewed. Data collected included signalment, complications, and assessment of function at last physical examination. Follow‐up information was obtained by phone conversations with owners. Complications were classified as minor, major II, major I, and catastrophic.Results: Thirty‐six PTA were performed in 30 dogs. Recorded complications included eight (22.2%) minor complications, 11 (30.6%) major II complications and 11 (30.6%) major I complications. One (2.8%) dog required amputation because of catastrophic complication. Owners provided follow‐up for 26 dogs at a median duration of 1215 days (range, 325‐3495) after surgery. The outcome was reported as full function in 12 dogs and acceptable function in 14 dogs, with no owners reporting unacceptable function. The owner of the dog in which amputation was required was not contacted. Incorrect contact details prevented owner follow‐up in the other three dogs, but all had acceptable function at last veterinary follow up.Conclusion: Dogs treated with PTA by medially applied plate had a high incidence of complications requiring surgical or medical management, although full or acceptable function was achieved in 29 of 30 dogs.Clinical significance:Pantarsal arthrodesis offers a predictably good medium to long‐term outcome in spite of a high risk of complications.


  • Accuracy of three‐dimensional printed patient‐specific drill guides for treatment of canine humeral intracondylar fissure

    by Tim G. Easter, Alexis Bilmont, Jonathan Pink, Bill Oxley

    Objective: To determine the accuracy of three‐dimensional printed patient‐specific drill guides (3D‐PDG) as treatment of humeral intracondylar fissures (HIF) in dogs.Study design: Retrospective consecutive case series.Animals: Client‐owned dogs with HIF treated with a 5‐mm transcondylar screw (TCS) placed from medial to lateral with a 3D‐PDG.Methods: The proposed TCS entry point and trajectory were planned using computed tomography (CT) data and computer‐aided design software (CAD), and a 3D‐PDG was produced. During surgery the 3D‐PDG was used to drill the pilot hole from medial to lateral; the guide was then removed, the pilot hole was overdrilled, and a 5‐mm TCS was placed. Postoperative CT data were imported into CAD software, and the entry points, exit points, and trajectories were compared between the planned and actual screw locations.Results: Sixteen elbows from 11 dogs were included. Mean (SD) entry point translation was 1.3 mm (0.64), with all screws entering cranial to the proposed location. Mean maximum screw angulation was 5.2° (2.10°), with most screws directed caudodistal to the desired trajectory. Mean (SD) exit point translation was 1.8 mm (0.89) from the planned location. There was no intra‐articular screw placement.Conclusion: Use of a 3D‐PDG permitted accurate placement of a mediolateral 5‐mm locking TCS within the humeral condyle.Clinical significance: Three‐dimensional printed patient‐specific drill guides should be considered as accurate and consistent for placing TCS for treatment of HIF in dogs.


  • Accuracy of placement of pedicle screws in the thoracolumbar spine of dogs with spinal deformities with three‐dimensionally printed patient‐specific drill guides

    by James H. Elford, Bill Oxley, Sebastien Behr

    Objective: To determine the accuracy of pedicle screw placement in the thoracic spine of dogs with spinal deformities with three‐dimensionally (3D) printed patient‐specific drill guides.Study design: Retrospective study.Sample population: Six dogs in which sixty pedicle screws were placed in the thoracolumbar spine.Methods: Medical records were searched between June 2017 and June 2018 for dogs with clinical signs associated with a thoracolumbar vertebral malformation. Inclusion criteria included MRI and computed tomography (CT) data that were used to create 3D printed patient‐specific drill guides. All dogs were stabilized dorsally with guided bicortical pedicle screws and polymethylmethacrylate. Accuracy of screw placement was assessed by immediately postoperative CT according to a modified Zdichavsky classification.Results: Five pugs and one French bulldog met the inclusion criteria. Sixty bicortical pedicle screws were placed; 96.7% were graded as I (optimal placement), and 3.3% were classified as IIa (partial penetration of the medial pedicle wall) according to a modified Zdichavsky classification.Conclusion: Three‐dimensionally printed patient‐specific drill guides allowed safe and accurate placement of pedicle screws in the thoracolumbar spine in dogs with vertebral malformation.Clinical significance: Three‐dimensionally printed patient‐specific drill guides are a safe and effective method of placing pedicle screws in dogs with thoracolumbar vertebral malformations.


  • A 3‐dimensional‐printed patient‐specific guide system for minimally invasive plate osteosynthesis of a comminuted mid‐diaphyseal humeral fracture in a cat

    by Bill Oxley

    Objective: To report the use of a 3‐dimensional (3D)‐printed patient‐specific reduction guide system to facilitate minimally invasive plate osteosynthesis (MIPO) of a humeral fracture in a cat.Study design: Case report.Animals: A 9‐year‐old male neutered domestic short hair cat weighing 4.4 kg.Methods: A 9‐year‐old male domestic short hair cat was presented with a comminuted, mid‐diaphyseal left humeral fracture. Computed tomographic data were processed to yield 3D mesh representations of both humeri and subsequently manipulated in computer‐aided design software. The mirrored, intact humerus was used as a template for appropriate spatial orientation of the major proximal and distal fracture fragments. Patient‐specific Ellis pin orientation guides and a reduction guide were designed and 3D printed. The guide system was used intraoperatively to align the major fracture fragments before application of locking internal fixation via standard MIPO surgical portals.Results: Internal fixation of the fracture resulted in appropriate bone alignment. Recovery was uncomplicated, with early return to normal limb function and radiographic evidence of advanced fracture healing after 4 months.Conclusion: A 3D‐printed patient‐specific reduction guide system facilitated accurate alignment of a comminuted humeral fracture during MIPO without intraoperative imaging.


  • Bilateral shoulder arthrodesis in a Pekinese using three-dimensional printed patient-specific osteotomy and reduction guides

    by Bill Oxley

    Summary: Objective: To report the use of computeraided design software for virtual surgical planning and design of three-dimensional printed patient-specific osteotomy and reduction guides for facilitation of bilateral shoulder arthrodesis in a dog.Methods: A three-year-old male entire Pekinese was presented unable to walk due to bilateral severe medial shoulder instability. Computed tomographic data was processed to yield three-dimensional mesh representations of the humeri and scapulae which could be manipulated in computeraided design software. Key virtual surgical planning steps included joint realignment, osteo-tomies of the glenoid and humeral head, and reduction. Virtual osteotomy and reduction guides were designed, three-dimensionally printed, and used intra-operatively.Results: Appropriate alignment, reduction and fixation of the humeri and scapulae were achieved bilaterally. The patient regained the ability to walk unassisted after two weeks and was subsequently able to exercise normally without lameness.Clinical significance: Patient-specific, three-dimensional printed osteotomy and reduction guides facilitated accurate bilateral shoulder arthrodeses.ORCID iD:http://orcid.org/0000-0002-2158-7133


  • Accuracy of a patient‐specific 3D printed drill guide for placement of cervical transpedicular screws

    by Sinead E. Hamilton‐Bennett, Bill Oxley, Sebastien Behr

    Objective: To develop a patient‐specific 3‐dimensional (3D) printed drill guide for placement of cervical transpedicular screws and to assess its accuracy.Study design: Prospective case‐series.Sample Population: Thirty‐two cervical pedicle screws (CPS) placed in 3 large breed dogs.Methods: Computed tomographic (CT) data of the cervical vertebrae were exported to a medical image processing software and 3D virtual vertebral models were created for each vertebra. These models were processed in a computer aided design (CAD) software to determine the optimal trajectory and size of the CPS. Virtual drill guides were created for each patient, 3D‐printed, and used intraoperatively. Locking titanium screw heads were bonded with polymethylmethacrylate cement to stabilize affected vertebral segments. Postoperative CT was used to assess the radiological accuracy of CPS placement in each dog. For each screw, CAD files were analyzed to determine a screw‐diameter‐to‐pedicle‐width‐ratio (SDPWR) at the narrowest point of the pedicle.Results: A total of 32 CPS were placed, measuring 3.5 mm (n = 20), 2.7 mm (n = 11), and 2.4 mm (n = 1) in diameter. The majority (29/32) of these screws were placed without evidence of vertebral canal breach (grade 0), whereas a vertebral canal breach <2 mm (grade 1) was detected in 3/32 screws. This outcome was achieved despite a mean SDPWR of 0.75 (range 0.58‐0.93).Conclusion: The use of a 3D‐printed patient‐specific drill guide permitted accurate placement of 32 bicortical pedicle screws in the caudal cervical vertebrae of 3 dogs. This technique may improve clinical outcome through superior biomechanical properties of screws, reduced surgical time, and reduced morbidity. These results warrant evaluation of patient outcome in a larger population.