Enhancing Recurrent Laryngeal Nerve Detection with Neural Autofluorescence in Thyroid Surgery
Authors:
- 14 November 2025
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of the American College of Surgeons
- Vol. 241 (6) , 992-999
Abstract
BACKGROUND: Recurrent laryngeal nerve (RLN) injury is a common and serious complication of thyroidectomy. This study evaluates the sensitivity and specificity of nerve autofluorescence using near-ultraviolet (NUV) light for RLN identification during thyroidectomy. STUDY DESIGN: A retrospective review of prospectively collected data was performed on 614 patients undergoing thyroidectomy for various indications. RLNs were identified using both conventional white light and NUV light autofluorescence techniques. RESULTS: Among the 614 patients, surgical indications included goiter (35%), well-differentiated thyroid carcinoma (20%), and thyroiditis (45%). A total of 1,230 RLN branches were identified using NUV light compared with 840 identified under conventional white light. NUV light autofluorescence demonstrated a sensitivity of 100% (95% CI 99.2 to 100) and specificity of 98.5% (95% CI 98.4 to 98.6) for RLN identification. Mean fluorescent light intensity for RLN (134.3 ± 12.7 pixels [px]) was significantly higher than that of the thyroid gland (33.7 ± 8.9 px) and adjacent tissues (14.4 ± 5.3 px; 1-way ANOVA: F = 842.1, p < 0.001). NUV imaging enabled enhanced visualization of anatomical variations of the RLN. A single case (0.2%) of transient unilateral RLN palsy was observed, occurring in a patient with well-differentiated thyroid carcinoma. CONCLUSIONS: NUV light-based nerve autofluorescence offers high sensitivity and specificity for RLN identification during thyroidectomy, outperforming traditional methods. Its real-time, noninvasive nature and ability to enhance anatomical visualization may contribute to improved surgical outcomes and reduced nerve injury risk.Keywords
This publication has 28 references indexed in Scilit:
- Thyroid surgery under nerve auto-fluorescence & artificial intelligence tissue identification software guidanceLangenbeck's Archives of Surgery, 2025
- Nerve autofluorescence under near-ultraviolet light: cutting-edge technology for intra-operative neural tissue visualization in 17 patientsSurgical Endoscopy, 2021
- Nerve autofluorescence in near-ultraviolet light markedly enhances nerve visualization in vivoSurgical Endoscopy, 2021
- Nerve spectroscopy: understanding peripheral nerve autofluorescence through photodynamicsSurgical Endoscopy, 2021
- Patient, thyroid, and surgeon related factors that make thyroidectomy difficult-cohort studyAnnals of Medicine & Surgery, 2020
- In vivo nerve identification in head and neck surgery using diffuse reflectance spectroscopyLaryngoscope Investigative Otolaryngology, 2018
- Continuous vagal IONM prevents recurrent laryngeal nerve paralysis by revealing initial EMG changes of impending neuropraxic injury: A prospective, multicenter studyThe Laryngoscope, 2014
- Surgical adverse events: a systematic reviewThe American Journal of Surgery, 2013
- Complications of Thyroid Surgery: How to Avoid Them, How to Manage Them, and Observations on Their Possible Effect on the Whole PatientWorld Journal of Surgery, 2000
- Relationship between vocal cord paralysis and benign thyroid diseaseHead & Neck, 1995