Fernando Dip
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Fernando Dip has a total of 205 co-authors. Here are the top co-authors by number of shared publications:
Raul J. Rosenthal
15 shared publications- Raul Jacobo Rosenthal
Department of Surgery, David Geffen School of Medicine at UCLA, Los Angeles, California, USA
8 shared publications Alberto Rancati
6 shared publicationsEmanuele Lo Menzo
Hospital de Clinicas Jose de San Martin, Buenos Aires, Argentina
6 shared publicationsDiego Sinagra
From the Department of General Surgery, University of Buenos Aires, Buenos Aires, Argentina (F Dip, R Aleman, HR Dip, Rancati, Eiben, Marinelli, Ghiselli, Sinagra, Rosenthal)
5 shared publicationsJorge Falco
University Hospital Das Clinicas, Buenos Aires, Argentina
4 shared publications
Latest Publications
- Open Access
- 1 March 2026
- Published by AME Publishing Company in Gland Surgery
- Vol. 15 (3) , 56
From reaction to prevention: rethinking vocal fold paralysis after thyroid surgery
From reaction to prevention: rethinking vocal fold paralysis after thyroid surgery
- 1 March 2026
- Published by AME Publishing Company in Gland Surgery
- Vol. 15 (3) , 56
Open AccessFrom reaction to prevention: rethinking vocal fold paralysis after thyroid surgery
From reaction to prevention: rethinking vocal fold paralysis after thyroid surgery
- 14 November 2025
- Published by Wolters Kluwer Health in Journal of the American College of Surgeons
- Vol. 241 (6) , 992-999
Enhancing Recurrent Laryngeal Nerve Detection with Neural Autofluorescence in Thyroid Surgery
BACKGROUND: Recurrent laryngeal nerve (RLN) injury is a common and serious complication of thyroidectomy. This study evaluates the sensitivity and specificity of nerve autofluorescence using near-ultraviolet (NUV) light for RLN identification during thyroidectomy. STUDY DESIGN: A retrospective review of prospectively collected data was performed on 614 patients undergoing thyroidectomy for various indications. RLNs were identified using both conventional white light and NUV light autofluorescence techniques. RESULTS: Among the 614 patients, surgical indications included goiter (35%), well-differentiated thyroid carcinoma (20%), and thyroiditis (45%). A total of 1,230 RLN branches were identified using NUV light compared with 840 identified under conventional white light. NUV light autofluorescence demonstrated a sensitivity of 100% (95% CI 99.2 to 100) and specificity of 98.5% (95% CI 98.4 to 98.6) for RLN identification. Mean fluorescent light intensity for RLN (134.3 ± 12.7 pixels [px]) was significantly higher than that of the thyroid gland (33.7 ± 8.9 px) and adjacent tissues (14.4 ± 5.3 px; 1-way ANOVA: F = 842.1, p < 0.001). NUV imaging enabled enhanced visualization of anatomical variations of the RLN. A single case (0.2%) of transient unilateral RLN palsy was observed, occurring in a patient with well-differentiated thyroid carcinoma. CONCLUSIONS: NUV light-based nerve autofluorescence offers high sensitivity and specificity for RLN identification during thyroidectomy, outperforming traditional methods. Its real-time, noninvasive nature and ability to enhance anatomical visualization may contribute to improved surgical outcomes and reduced nerve injury risk.
- 14 November 2025
- Published by Wolters Kluwer Health in Journal of the American College of Surgeons
- Vol. 241 (6) , 992-999
Enhancing Recurrent Laryngeal Nerve Detection with Neural Autofluorescence in Thyroid Surgery
BACKGROUND: Recurrent laryngeal nerve (RLN) injury is a common and serious complication of thyroidectomy. This study evaluates the sensitivity and specificity of nerve autofluorescence using near-ultraviolet (NUV) light for RLN identification during thyroidectomy. STUDY DESIGN: A retrospective review of prospectively collected data was performed on 614 patients undergoing thyroidectomy for various indications. RLNs were identified using both conventional white light and NUV light autofluorescence techniques. RESULTS: Among the 614 patients, surgical indications included goiter (35%), well-differentiated thyroid carcinoma (20%), and thyroiditis (45%). A total of 1,230 RLN branches were identified using NUV light compared with 840 identified under conventional white light. NUV light autofluorescence demonstrated a sensitivity of 100% (95% CI 99.2 to 100) and specificity of 98.5% (95% CI 98.4 to 98.6) for RLN identification. Mean fluorescent light intensity for RLN (134.3 ± 12.7 pixels [px]) was significantly higher than that of the thyroid gland (33.7 ± 8.9 px) and adjacent tissues (14.4 ± 5.3 px; 1-way ANOVA: F = 842.1, p < 0.001). NUV imaging enabled enhanced visualization of anatomical variations of the RLN. A single case (0.2%) of transient unilateral RLN palsy was observed, occurring in a patient with well-differentiated thyroid carcinoma. CONCLUSIONS: NUV light-based nerve autofluorescence offers high sensitivity and specificity for RLN identification during thyroidectomy, outperforming traditional methods. Its real-time, noninvasive nature and ability to enhance anatomical visualization may contribute to improved surgical outcomes and reduced nerve injury risk.
- 23 June 2025
- Published by Springer Nature in Surgical Endoscopy
- Vol. 39 (8) , 4890-4898
Global insights: fluorescence guided surgery
Fluorescence guided surgery (FGS) has been progressively and globally adapted by multiple surgical disciplines over the last decade. Determining its reach and rate of expansion as a navigational surgical technique is challenging from traditional surveys. Google-trends (GT) was introduced as an ongoing-developing web-kit providing data on search trends to analyze the general population interest on specific topics. The purpose of this study is to implement GT data as an indicator for the world's interest in FGS. GT was used to access data for specific medical subject headings (MeSH) terms associated with FGS, from 2019 to 2024. Collected data included interest over time, interest by country/continent, and related queries. Data were represented as search interest relative to the highest point on global charts for a given region and time. A value of 100% was set as peak popularity for searched term (s). Multiple correlation analyzes were performed between MeSH terms and surgical subspecialties. The number of worldwide searches related to the MeSH terms indocyanine green (ICG) and fluorescence imaging (FI) have consistently increased over time, from 47 and 64% in 2019, to 88 and 69% by the end of 2024, respectively. America withholds the continent with the highest interest for ICG and FI, followed by Europe and Asia with 50 and 45%, respectively. Correlation analyzes with surgical subspecialties showed a significant positive relationship between the interest over time for ICG and fluorescent imaging when paired with endocrine surgery (p < 0.0001; p < 0.0001), urologic surgery (p = 0.003; p = 0.002), and gynecologic surgery (p < 0.0001; p = 0.005). The data conveyed by GT complements the outlook of FGS across the world. Implementing these trends alongside healthcare advocacy and patient therapeutic education, FGS can further expand its applications and potentials to practice safe surgery.
- 23 June 2025
- Published by Springer Nature in Surgical Endoscopy
- Vol. 39 (8) , 4890-4898
Global insights: fluorescence guided surgery
Fluorescence guided surgery (FGS) has been progressively and globally adapted by multiple surgical disciplines over the last decade. Determining its reach and rate of expansion as a navigational surgical technique is challenging from traditional surveys. Google-trends (GT) was introduced as an ongoing-developing web-kit providing data on search trends to analyze the general population interest on specific topics. The purpose of this study is to implement GT data as an indicator for the world's interest in FGS. GT was used to access data for specific medical subject headings (MeSH) terms associated with FGS, from 2019 to 2024. Collected data included interest over time, interest by country/continent, and related queries. Data were represented as search interest relative to the highest point on global charts for a given region and time. A value of 100% was set as peak popularity for searched term (s). Multiple correlation analyzes were performed between MeSH terms and surgical subspecialties. The number of worldwide searches related to the MeSH terms indocyanine green (ICG) and fluorescence imaging (FI) have consistently increased over time, from 47 and 64% in 2019, to 88 and 69% by the end of 2024, respectively. America withholds the continent with the highest interest for ICG and FI, followed by Europe and Asia with 50 and 45%, respectively. Correlation analyzes with surgical subspecialties showed a significant positive relationship between the interest over time for ICG and fluorescent imaging when paired with endocrine surgery (p < 0.0001; p < 0.0001), urologic surgery (p = 0.003; p = 0.002), and gynecologic surgery (p < 0.0001; p = 0.005). The data conveyed by GT complements the outlook of FGS across the world. Implementing these trends alongside healthcare advocacy and patient therapeutic education, FGS can further expand its applications and potentials to practice safe surgery.
- Open Access
- 6 January 2025
- Published by Springer Nature in Cureus
- Vol. 17 (1) , e77025
Nerve-Sparing Parotidectomy Guided by Nerve Auto-Fluorescence Technology
Parotidectomy is a commonly performed surgery for various indications, including inflammatory conditions, infection, congenital symptomatic malformations, and neoplasm resection. Irrespective of its indication, the performance requires meticulous surgical navigation by highly experienced surgeons because of its proximity to the facial nerve. While the surgical technique continues to evolve, nerve paralysis and nerve-related complications remain a significant concern following an intervention. Due to the high learning curve required to reduce the incidence of surgical iatrogenic events, a novel device has been developed to emit real-time nerve auto-fluorescence in parallel to artificial intelligence (AI) surgical navigation software (SNS) feedback to isolate and accurately identify nerve structures during surgery. The authors herein present one of the first cases of a benign parotid tumor excision implementing dual AI and nerve auto-fluorescence technology for a minimally invasive, nerve-sparing parotidectomy. This report underscores the potential of nerve auto-fluorescence-guided surgery to improve surgical precision and patient outcomes.
- 6 January 2025
- Published by Springer Nature in Cureus
- Vol. 17 (1) , e77025
Open AccessNerve-Sparing Parotidectomy Guided by Nerve Auto-Fluorescence Technology
Parotidectomy is a commonly performed surgery for various indications, including inflammatory conditions, infection, congenital symptomatic malformations, and neoplasm resection. Irrespective of its indication, the performance requires meticulous surgical navigation by highly experienced surgeons because of its proximity to the facial nerve. While the surgical technique continues to evolve, nerve paralysis and nerve-related complications remain a significant concern following an intervention. Due to the high learning curve required to reduce the incidence of surgical iatrogenic events, a novel device has been developed to emit real-time nerve auto-fluorescence in parallel to artificial intelligence (AI) surgical navigation software (SNS) feedback to isolate and accurately identify nerve structures during surgery. The authors herein present one of the first cases of a benign parotid tumor excision implementing dual AI and nerve auto-fluorescence technology for a minimally invasive, nerve-sparing parotidectomy. This report underscores the potential of nerve auto-fluorescence-guided surgery to improve surgical precision and patient outcomes.
- 4 January 2025
- Published by Springer Nature in Langenbeck's Archives of Surgery
- Vol. 410 (1) , 1-5
Thyroid surgery under nerve auto-fluorescence & artificial intelligence tissue identification software guidance
Thyroid cancer is a common malignancy that requires comprehensive clinical evaluation prior to adequate surgical management. Over the last three decades thyroid surgery has tripled and is considered one of the most commonly performed procedures in general surgery. These procedures are associated with potential postoperative complications with significant deterioration in the patient’s quality of life. While the current rates of recurrent laryngeal nerve injury following thyroidectomy have decreased secondary to intraoperative neuromonitoring, thyroid surgery remains the leading cause of iatrogenic injury. The authors herein present a case of a thyroid nodule with cervical lymph node involvement undergoing total thyroidectomy guided by near-ultraviolet (NUV) imaging nerve auto-fluorescent technology to visualize, identify and protect vital structures.
- 4 January 2025
- Published by Springer Nature in Langenbeck's Archives of Surgery
- Vol. 410 (1) , 1-5
Thyroid surgery under nerve auto-fluorescence & artificial intelligence tissue identification software guidance
Thyroid cancer is a common malignancy that requires comprehensive clinical evaluation prior to adequate surgical management. Over the last three decades thyroid surgery has tripled and is considered one of the most commonly performed procedures in general surgery. These procedures are associated with potential postoperative complications with significant deterioration in the patient’s quality of life. While the current rates of recurrent laryngeal nerve injury following thyroidectomy have decreased secondary to intraoperative neuromonitoring, thyroid surgery remains the leading cause of iatrogenic injury. The authors herein present a case of a thyroid nodule with cervical lymph node involvement undergoing total thyroidectomy guided by near-ultraviolet (NUV) imaging nerve auto-fluorescent technology to visualize, identify and protect vital structures.
- 1 March 2024
- Published by Asociacion Argentina de Cirugia in Revista Argentina de Cirugia
- Vol. 116 (1) , 24-31
Algorithm to select chest wall perforator flaps in immediate conservative breast surgery reconstruction
Background: Chest wall perforator flaps are a good option for immediate breast reconstruction after conservative surgery. Objective: The aim of this study was to describe the clinical results of an algorithm for using chest wall perforator flaps for breast reconstruction after breast-conserving surgery for breast cancer. Material and methods: We conducted a descriptive and retrospective study. The information was retrieved from the medical records of the patients diagnosed with breast cancer who underwent breast-conserving surgery and required reconstruction using chest wall perforator flaps between January 2020 and March 2022. The indications included volume deficit, contour defect and asymmetry. The vascular pedicle of the flap was evaluated by color Doppler ultrasound in all cases, which allowed us to follow an algorithm for selecting the best flap option. Results: Twenty flaps were made in 19 patients. Mean age: 52 years ± 11 (range 30-76). There were no intraoperative complications. One patient required reoperation due to a hematoma with compression of the vascular pedicle of the flap with partial flap loss, and another flap presented superficial epidermolysis. There were no cases of complete flap loss. All the patients underwent postoperative radiation therapy without loss of volume or retractions. Mean follow-up was 15 months. At 6 months, patients rated the results as excellent, good, and fair in 7, 11, and 2 cases, respectively. Conclusion: The selection of local perforator flaps to correct breast defects after conservative surgery, using preoperative color Doppler ultrasound to identify the vascular pedicle and a specific algorithm, allowed us to obtain satisfactory aesthetic results without the need for alloplastic elements or subsequent revisions.
- 1 March 2024
- Published by Asociacion Argentina de Cirugia in Revista Argentina de Cirugia
- Vol. 116 (1) , 24-31
Algorithm to select chest wall perforator flaps in immediate conservative breast surgery reconstruction
Background: Chest wall perforator flaps are a good option for immediate breast reconstruction after conservative surgery. Objective: The aim of this study was to describe the clinical results of an algorithm for using chest wall perforator flaps for breast reconstruction after breast-conserving surgery for breast cancer. Material and methods: We conducted a descriptive and retrospective study. The information was retrieved from the medical records of the patients diagnosed with breast cancer who underwent breast-conserving surgery and required reconstruction using chest wall perforator flaps between January 2020 and March 2022. The indications included volume deficit, contour defect and asymmetry. The vascular pedicle of the flap was evaluated by color Doppler ultrasound in all cases, which allowed us to follow an algorithm for selecting the best flap option. Results: Twenty flaps were made in 19 patients. Mean age: 52 years ± 11 (range 30-76). There were no intraoperative complications. One patient required reoperation due to a hematoma with compression of the vascular pedicle of the flap with partial flap loss, and another flap presented superficial epidermolysis. There were no cases of complete flap loss. All the patients underwent postoperative radiation therapy without loss of volume or retractions. Mean follow-up was 15 months. At 6 months, patients rated the results as excellent, good, and fair in 7, 11, and 2 cases, respectively. Conclusion: The selection of local perforator flaps to correct breast defects after conservative surgery, using preoperative color Doppler ultrasound to identify the vascular pedicle and a specific algorithm, allowed us to obtain satisfactory aesthetic results without the need for alloplastic elements or subsequent revisions.
- Open Access
Consensus Statement on the Use of Near-Infrared Fluorescence Imaging during Pancreatic Cancer Surgery Based on a Delphi Study: Surgeons’ Perspectives on Current Use and Future Recommendations
Indocyanine green (ICG) is one of the only clinically approved near-infrared (NIR) fluorophores used during fluorescence-guided surgery (FGS), but it lacks tumor specificity for pancreatic ductal adenocarcinoma (PDAC). Several tumor-targeted fluorescent probes have been evaluated in PDAC patients, yet no uniformity or consensus exists among the surgical community on the current and future needs of FGS during PDAC surgery. In this first-published consensus report on FGS for PDAC, expert opinions were gathered on current use and future recommendations from surgeons’ perspectives. A Delphi survey was conducted among international FGS experts via Google Forms. Experts were asked to anonymously vote on 76 statements, with ≥70% agreement considered consensus and ≥80% participation/statement considered vote robustness. Consensus was reached for 61/76 statements. All statements were considered robust. All experts agreed that FGS is safe with few drawbacks during PDAC surgery, but that it should not yet be implemented routinely for tumor identification due to a lack of PDAC-specific NIR tracers and insufficient evidence proving FGS’s benefit over standard methods. However, aside from tumor imaging, surgeons suggest they would benefit from visualizing vasculature and surrounding anatomy with ICG during PDAC surgery. Future research could also benefit from identifying neuroendocrine tumors. More research focusing on standardization and combining tumor identification and vital-structure imaging would greatly improve FGS’s use during PDAC surgery.
Open AccessConsensus Statement on the Use of Near-Infrared Fluorescence Imaging during Pancreatic Cancer Surgery Based on a Delphi Study: Surgeons’ Perspectives on Current Use and Future Recommendations
Indocyanine green (ICG) is one of the only clinically approved near-infrared (NIR) fluorophores used during fluorescence-guided surgery (FGS), but it lacks tumor specificity for pancreatic ductal adenocarcinoma (PDAC). Several tumor-targeted fluorescent probes have been evaluated in PDAC patients, yet no uniformity or consensus exists among the surgical community on the current and future needs of FGS during PDAC surgery. In this first-published consensus report on FGS for PDAC, expert opinions were gathered on current use and future recommendations from surgeons’ perspectives. A Delphi survey was conducted among international FGS experts via Google Forms. Experts were asked to anonymously vote on 76 statements, with ≥70% agreement considered consensus and ≥80% participation/statement considered vote robustness. Consensus was reached for 61/76 statements. All statements were considered robust. All experts agreed that FGS is safe with few drawbacks during PDAC surgery, but that it should not yet be implemented routinely for tumor identification due to a lack of PDAC-specific NIR tracers and insufficient evidence proving FGS’s benefit over standard methods. However, aside from tumor imaging, surgeons suggest they would benefit from visualizing vasculature and surrounding anatomy with ICG during PDAC surgery. Future research could also benefit from identifying neuroendocrine tumors. More research focusing on standardization and combining tumor identification and vital-structure imaging would greatly improve FGS’s use during PDAC surgery.