3DMPR – a robust morphological approach for applying phase retrieval in proximity to highly attenuating objects in computed tomography
Open Access
- 31 July 2025
- journal article
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 32 (5) , 1319-1327
Abstract
X-ray imaging is a fast, precise and non-invasive method of imaging which, when combined with computed tomography, provides detailed 3D rendering of samples. Incorporating propagation-based phase contrast can vastly improve data quality for weakly attenuating samples via phase retrieval, allowing radiation exposure to be reduced. However, applying phase retrieval to multi-material samples commonly requires the choice of which material boundary to tune the reconstruction. Selecting the boundary with strongest phase contrast increases noise suppression, but at the detriment of over-blurring other interfaces and potentially removing quantitative sample information. Additionally, conventional phase retrieval algorithms cannot be used for regions bounded by more than one material, requiring alternative methods. Here we present a computationally efficient, non-iterative nor AI-mediated method for applying strong phase retrieval, whilst preserving sharp boundaries for all materials within the sample. 3D phase retrieval is combined with morphological operations to prevent over-blurring artefacts from being introduced, while avoiding the potentially long convergence times required by iterative approaches. This technique, entitled 3DMPR, was tested on phase contrast images of a rabbit kitten brain encased by the surrounding dense skull. Using 24 keV synchrotron radiation with a 5 m propagation distance, 3DMPR provided a 6.8-fold improvement in the signal-to-noise ratio (SNR) of brain tissue over the standard phase retrieval procedure, without over-smoothing the images. Simultaneous quantification of edge resolution and SNR gain was performed with an aluminium–water phantom imaged using a microfocus X-ray tube at 35 kV p and 0.576 m effective propagation distance. There, 3DMPR provided a four-fold SNR boost whilst preserving the boundary spatial resolution at 54 ± 1 µm, compared with 108 ± 2 µm using conventional phase retrieval. These results illustrate the ability of 3DMPR to create new avenues of dose reduction in clinical settings.Keywords
Funding Information
- Australian Research Council (FT18010037)
- National Health and Medical Research Council (2012257)
This publication has 33 references indexed in Scilit:
- The ASTRA Toolbox: A platform for advanced algorithm development in electron tomographyUltramicroscopy, 2015
- Neuroimaging in adult penetrating brain injury: a guide for radiographersJournal of Medical Radiation Sciences, 2015
- Current and future diagnostic tools for traumatic brain injuryHandbook of Clinical Neurology, 2015
- Functionalized synchrotron in-line phase-contrast computed tomography: a novel approach for simultaneous quantification of structural alterations and localization of barium-labelled alveolar macrophages within mouse lung samplesJournal of Synchrotron Radiation, 2015
- Ventilation/perfusion mismatch during lung aeration at birthJournal of Applied Physiology, 2014
- Quantitative evaluation of a single-distance phase-retrieval method applied on in-line phase-contrast images of a mouse lungJournal of Synchrotron Radiation, 2014
- Interface-specific x-ray phase retrieval tomography of complex biological organsPhysics in Medicine & Biology, 2011
- 2D and 3D X-ray phase retrieval of multi-material objects using a single defocus distanceOptics Express, 2010
- Artifacts in CT: Recognition and AvoidanceRadioGraphics, 2004
- Simultaneous phase and amplitude extraction from a single defocused image of a homogeneous objectJournal of Microscopy, 2002