MKMarcus J. Kitchen

Marcus J. Kitchen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Marcus J. Kitchen has a total of 276 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Estimations of lung structural properties from a single propagation-based dark-field x-ray image

    by D W O’COnnell, K S Morgan, L C P Croton, J A Pollock, G Ruben, K J Crossley, M J Wallace, E V McGillick, S B Hooper, M J Kitchen

    Objective. To employ a single-projection dark-field imaging approach to obtain statistical information on alveolar size and number as key structural indicators of lung health. Approach. The algorithm employed here retrieves the projected thickness of the sample from a propagation-based phase contrast image using the transport-of-intensity equation. The first Born approximation is then used to isolate the dark-field signal associated with edge scattering, which increases the visibility of microstructure boundaries. Poly(methyl methacrylate) spheres of known sizes were imaged first as an idealised alveolar model. The dark-field signal was then recovered from propagation-based phase-contrast x-ray images of the lungs of small mammals using this method. Main results. The retrieved dark-field signal was found to be proportional to both the alveolar size ( R 2 = 0.85 ) and the number in projection ( R 2 = 0.69 ), and these measurements could be combined to provide an estimate of the total surface area of the alveolar interfaces ( R 2 = 0.78 ). Significance. This demonstrates the approach’s ability to potentially indicate lung health using the dark-field signal retrieved from a single-phase-contrast x-ray image.

  • Surfactant enhances the distribution of ventilation in partially aerated lungs of preterm rabbits

    by Francesco Cavigioli, Indya M. Davies, Gianluca Lista, Katie Lee, Megan J. Wallace, Marcus J. Kitchen, Dominic Jurkschat, Corinna Binder-Heschl, Arjan B. Te Pas, Stuart B. Hooper, et al.

    Preterm newborns commonly receive intermittent positive pressure ventilation (iPPV) at birth, but the optimal approach that facilitates uniform lung aeration is unknown, particularly in a partially aerated lung. We have shown that surfactant administration to partially aerated lungs markedly enhances aeration of unaerated lung regions, which redistributes the incoming tidal volume to more evenly ventilate the lung. These experimental findings support the rationale to administer surfactant as soon as possible after birth in preterm infants.

  • Open Access

    In Vivo 4D X-Ray Dark-Field Lung Imaging in Mice

    by Ying Ying How, Nicole Reyne, Michelle K. Croughan, Patricia Cmielewski, Daniel Batey, Lucy F. Costello, Ronan Smith, Jannis N. Ahlers, Marian Cholewa, Magdalena Kolodziej, et al.

    X-ray dark-field imaging is well-suited to visualizing the health of the lungs because the alveoli create a strong dark-field signal. However, time-resolved and tomographic (i.e., 4D) dark-field imaging is challenging, since most x-ray dark-field techniques require multiple sample exposures, captured while scanning the position of crystals or gratings. Here, we present the first in vivo 4D x-ray dark-field lung imaging in mice. This was achieved by synchronizing the data acquisition process of a single-exposure grid-based imaging approach with the breath cycle. The short data acquisition time per dark-field projection made this approach feasible for 4D x-ray dark-field imaging by minimizing the motion-blurring effect and the total time required. Images were captured from a control mouse and from mouse models of muco-obstructive disease and lung cancer, where a change in the size of the alveoli was expected. This work demonstrates that the 4D dark-field signal provides complementary tomographic information that is inaccessible from conventional attenuation-based CT images, in particular, measurements that indicate changes in the size of the alveoli from different parts of the lungs during the breath cycle, with examples shown across the different models. By quantifying the dark-field signal and relating it to physical properties of the alveoli, this technique could be used to perform functional lung imaging that allows the assessment of both global and regional lung conditions where the size or expansion of the alveoli is affected.


  • Open Access

    CT ring artefact suppression via detector calibration: from monochromatic to polychromatic x-ray sources

    by L C P Croton, G Ruben, K S Morgan, A S McGovern, J A Pollock, M J Kitchen

    This study validates the effectiveness of a quantitative detector calibration—originally developed for monochromatic synchrotron radiation—when applied with a polychromatic x-ray source, using both a Hamamatsu CMOS flat panel detector and a WidePIX photon-counting detector with Timepix chips. We show that, despite the energy dependence of the detector response, this calibration is a simple yet robust tool for suppressing computed tomography (CT) ring artefacts in both attenuation contrast and phase contrast CT. Furthermore, we demonstrate that this algorithm is effective even when the ring artefacts are present at a level below the shot noise. This makes it especially useful for data that is filtered in a way that suppresses noise, such as low-dose imaging via phase retrieval.

  • Open Access

    In situ propagation-based lung computed tomography for large animal models

    by Lorenzo D'AMico, Lucy Costello, Yakov Nesterets, Martin Donnelley, Timur Gureyev, Anton Maksimenko, Cathy Beck, Jannis Ahlers, Ronan Smith, Ying Ying How, et al.

    The lung is a complex organ with a hierarchical structure, containing four times more air than tissue. It is in constant contact with environmental factors such as pollution and pathogens, leading to pathological alterations at various hierarchical levels. Because of its intricate structure and continuous movement, lung imaging presents significant challenges for most existing techniques. Recent advancements in phase-contrast computed tomography and photon-counting detectors have greatly enhanced lung imaging capabilities. Specifically, propagation-based imaging (PBI), a phase-contrast method that does not require optical elements, has proven particularly effective at low X-ray dose rates due to the strong phase shifts between lung tissue and aerated regions. This study introduces an in situ imaging approach for large-scale lungs using PBI at the Imaging and Medical Beamline (IMBL) of the Australian Synchrotron. We investigated optimal conditions for PBI, including energy and propagation distance settings, and found that an X-ray beam energy of 70 keV combined with a 7 m propagation distance yields the highest image quality in terms of contrast-to-noise ratio while also delivering the lowest radiation dose. Furthermore, Monte Carlo simulations were performed on the reconstructed volume to calculate absorbed radiation doses in tissues. These findings provide valuable insights for designing future experiments aimed at minimizing radiation exposure and potentially enable in vivo applications in larger animals or even humans.


  • Open Access

    Role of the Chest Wall in Newborn Respiratory Function at Birth

    by C. Diedericks, K. J. Crossley, I. M. Davies, D. A. Blank, S. J. E. Cramer, M. J. Wallace, A. B. Te Pas, M. J. Kitchen, S. B. Hooper

    The chest wall significantly impacts respiratory function after birth, but its role in the newborn remains poorly understood as it is structurally and functionally different from adults. In neonates, the chest wall is highly compliant, which allows it to expand to accommodate the incoming air and the lung liquid cleared into the pulmonary interstitium during lung aeration. However, the high neonatal chest wall compliance predisposes it to distortion, which reduces breathing efficiency and necessitates respiratory muscle activation to stabilize it. This increases the work of breathing and, when combined with fewer fatigue‐resistant Type I muscle fibers (slow twitch, high oxidative capacity) in the diaphragm muscle, the risk of respiratory fatigue is increased. Nevertheless, as the chest wall is highly compliant in the newborn, recent studies have demonstrated that extra‐thoracic pressures can influence chest wall mechanics. Positive extra‐thoracic pressures (such as those applied with tight swaddling) limit chest wall expansion, whereas a small constant negative extra‐thoracic pressure stabilizes the chest wall and improves oxygenation in neonates. In this review, we aim to summarize the current evidence on chest wall function in fetuses and neonates, particularly during lung liquid clearance, lung aeration, and breathing after birth. Furthermore, we will explore how knowledge from newborn respiratory physiology may inform our understanding of the respiratory consequences of pulmonary oedema in adults, such as occurred during the initial stages of the COVID‐19 pandemic.


  • A small constant external negative pressure improves lung aeration at birth in rabbit kittens with a diaphragmatic hernia

    by Paige J. Riddington, Philip L. J. DeKoninck, Indya M. Davies, Dominic Jurkschat, Megan J. Wallace, Janneke Dekker, Arjan B. Te Pas, Marcus J. Kitchen, Stuart B. Hooper, Kelly J. Crossley

    This study demonstrates that a small constant external negative pressure applied during conventional mechanical ventilation improves lung aeration and achieves set tidal volumes with significantly lower peak inflation pressures in rabbit kittens with a diaphragmatic hernia and severe lung hypoplasia. The negative extrathoracic pressure improved dynamic lung compliance and stabilized the chest wall. Our findings indicate that negative extrathoracic pressures do more than simply act to replace a positive end-expiratory pressure to enhance respiratory function.

  • Open Access

    3DMPR – a robust morphological approach for applying phase retrieval in proximity to highly attenuating objects in computed tomography

    by James A. Pollock, L. C. P. Croton, K. S. Morgan, K. J. Crossley, M. J. Wallace, G. A. Buckley, S. B. Hooper, M. J. Kitchen

    X-ray imaging is a fast, precise and non-invasive method of imaging which, when combined with computed tomography, provides detailed 3D rendering of samples. Incorporating propagation-based phase contrast can vastly improve data quality for weakly attenuating samples via phase retrieval, allowing radiation exposure to be reduced. However, applying phase retrieval to multi-material samples commonly requires the choice of which material boundary to tune the reconstruction. Selecting the boundary with strongest phase contrast increases noise suppression, but at the detriment of over-blurring other interfaces and potentially removing quantitative sample information. Additionally, conventional phase retrieval algorithms cannot be used for regions bounded by more than one material, requiring alternative methods. Here we present a computationally efficient, non-iterative nor AI-mediated method for applying strong phase retrieval, whilst preserving sharp boundaries for all materials within the sample. 3D phase retrieval is combined with morphological operations to prevent over-blurring artefacts from being introduced, while avoiding the potentially long convergence times required by iterative approaches. This technique, entitled 3DMPR, was tested on phase contrast images of a rabbit kitten brain encased by the surrounding dense skull. Using 24 keV synchrotron radiation with a 5 m propagation distance, 3DMPR provided a 6.8-fold improvement in the signal-to-noise ratio (SNR) of brain tissue over the standard phase retrieval procedure, without over-smoothing the images. Simultaneous quantification of edge resolution and SNR gain was performed with an aluminium–water phantom imaged using a microfocus X-ray tube at 35 kV p and 0.576 m effective propagation distance. There, 3DMPR provided a four-fold SNR boost whilst preserving the boundary spatial resolution at 54 ± 1 µm, compared with 108 ± 2 µm using conventional phase retrieval. These results illustrate the ability of 3DMPR to create new avenues of dose reduction in clinical settings.

  • Open Access

    Single-exposure x-ray dark-field imaging via a dual-energy propagation-based setup

    by Jannis N. Ahlers, Konstantin M. Pavlov, Marcus J. Kitchen, Stephanie A. Harker, Emily J. Pryor, James A. Pollock, Michelle K. Croughan, Ying Ying How, Marie-Christine Zdora, Lucy F. Costello, et al.

    X-ray dark-field imaging visualizes scattering from sample microstructure and has found application in medical and security contexts. While most x-ray dark-field imaging techniques rely on masks, gratings, or crystals, recent work on the Fokker–Planck model of diffusive imaging has enabled dark-field imaging in the propagation-based geometry. Images captured at multiple propagation distances or x-ray energies can be used to reconstruct dark-field from propagation-based images but have previously required multiple exposures. Here, we show single-exposure dark-field imaging by exploiting the harmonic content in a monochromatized synchrotron beam and utilizing an energy-discriminating photon-counting detector to capture dual-energy propagation-based images. The method is validated by filming time-varying samples, showing the advantage of the dark-field contrast in analyzing dynamic evolution. We measure and adjust for the impact of detector charge-sharing on the images. This work opens the way for dynamic dark-field x-ray imaging without the need for a high-stability setup and precision optics.


  • Open Access

    X-ray dark-field via spectral propagation-based imaging

    by Jannis N. Ahlers, Konstantin M. Pavlov, Marcus J. Kitchen, Kaye S. Morgan

    Dark-field X-ray imaging visualizes scattering from unresolved microstructure. Most dark-field imaging techniques rely on crystals or structured illumination, but recent work has shown that dark-field effects are observable in straightforward propagation-based imaging (PBI). Based on the single-material X-ray Fokker–Planck equation with an a priori dark-field energy dependence, we propose an algorithm to extract phase and dark-field effects from dual-energy PBI images. We successfully apply the dark-field retrieval algorithm to simulated and experimental dual-energy data, and show that by accounting for dark-field effects, projected thickness reconstruction is improved compared to the classic Paganin algorithm. With the emergence of spectral detectors, the method could enable single-exposure dark-field imaging of dynamic and living samples.