Effective R-value of enclosed reflective space for different building applications
- 11 October 2019
- journal article
- research article
- Published by SAGE Publications in Journal of Building Physics
- Vol. 43 (5) , 398-427
Abstract
Many parts of the building envelopes contain enclosed airspaces. Also, the insulating glass units in fenestration systems, such as curtain walls, windows, and skylight devices, contain enclosed spaces that are normally filled with air or heavy gas such as argon, xenon, or krypton. The thermal resistance (R-value) of an enclosed space depends mainly on the type of the filling gas, emissivity of all surfaces that bound the space, the size and orientation of the space, the direction of heat flow through the space, and the respective temperatures of all surfaces that define the space. Assessing the energy performance of building envelopes and fenestration systems, subjected to different climatic conditions, requires accurate determination of the R-values of the enclosed spaces. In this study, a comprehensive review is conducted on the thermal performance of enclosed airspaces for different building applications. This review includes the computational and experimental methods for determining the effective R-value of enclosed reflective airspaces. Also, the different parameters that affect the thermal performance of enclosed airspaces are discussed. These parameters include the following: (a) dimensions, (b) inclination angles, (c) directions of heat flow, (d) emissivity of all surfaces that bound the space, and (e) operating conditions. Moreover, numerical simulations are conducted using a previously developed and validated model to investigate the effect of the inclination angle, direction of heat transfer, and the coating emissivity on the R-values of enclosed spaces when they are filled with different types of gases.Keywords
This publication has 27 references indexed in Scilit:
- Practical correlation for thermal resistance of horizontal enclosed airspaces with downward heat flow for building applicationsJournal of Building Physics, 2013
- Long-term hygrothermal performance of white and black roofs in North American climatesBuilding and Environment, 2012
- Thermal response of basement wall systems with low-emissivity material and furred airspaceJournal of Building Physics, 2011
- Thermal analysis of above-grade wall assembly with low emissivity materials and furred airspaceBuilding and Environment, 2011
- Analysis of impact of daylight time savings on energy use of buildings in KuwaitEnergy Policy, 2011
- Performance characteristics and practical applications of common building thermal insulation materialsBuilding and Environment, 2005
- On the performance of radiant barriers in combination with different attic insulation levelsEnergy and Buildings, 2000
- Two-Dimensional Heat Transfer Effects on Vacuum and Reflective InsulationsJournal of Thermal Insulation, 1991
- Prediction of the Thermal Performance of Single and Multi-Airspace Reflective Insulation Materials1991
- Thermal Resistance of Wall Cavities Containing Reflective InsulationJournal of Solar Energy Engineering, 1986