Influence of Placement of Overhead Ground Wires on Steady State Induction in AC-DC Hybrid Transmission Corridor
- 18 June 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 33 (6) , 2999-3008
Abstract
To meet the growing power demand of the future, utilities and researchers have considered the addition of dc circuits in existing transmission corridors. The previous research has focused on analyzing the field environment, steady state induction and the negative effects of induction in the hybrid transmission lines. The overhead ground wires (OHGWs) have been used only for improving the lightning performance of overhead lines (OHL). In this paper, the spatial position of OHGWs have been studied with the objective of minimizing the steady state induction between power conductors as well as poorly grounded metallic objects like railroads and fences present near the ac-dc OHL. Candidate space for placement of OHGWs having shielding failure rate (SFR) of less than 4 is identified using the conventional electro-geometric model (EGM). The steady state induction in the power conductors and nearby metallic objects is studied as a function of position of OHGWs using electro-magnetic transient (EMT) simulation. The results indicate a strong correlation between the height of OHGWs and magnitude of induced voltage in power conductors, and metallic objects underneath the transmission line. The conscious effort in placement of OHGWs can reduce the magnitude of induced voltages while ensuring adequate lightning performance.Keywords
Funding Information
- Ministry of Trade, Industry, and Energy of Korea
- Human Resources Program in Energy Technology
- Korea Institute of Energy Technology Evaluation and Planning (20174030201780)
- Korea Electric Power Corporation (R16XA01)
This publication has 17 references indexed in Scilit:
- Investigation on Shielding Failure of a Novel 400-k$\text{V}$ Double-Circuit Composite TowerIEEE Transactions on Power Delivery, 2017
- Analysis of electromagnetic coupling of HVAC cable section partly installed in parallel with HVDC lines in one corridorInternational Journal of Electrical Power & Energy Systems, 2015
- Network transient responses to varying HVAC line length along a HVDC transmission corridor2011
- Analysis of Coupling Effects on Overhead VSC-HVDC Transmission Lines From AC Lines With Shared Right of WayIEEE Transactions on Power Delivery, 2010
- A Calculation Method for the Hybrid Electric Field Under UHVAC and UHVDC Transmission Lines in the Same CorridorIEEE Transactions on Power Delivery, 2010
- Induced Voltage and Current in Parallel Transmission Lines: Causes and ConcernsIEEE Transactions on Power Delivery, 2008
- Induced overvoltages on an AC-DC hybrid transmission systemIEEE Transactions on Power Delivery, 1995
- The effect of HVAC-HVDC line separation in a hybrid corridorIEEE Transactions on Power Delivery, 1989
- Parallel AC/DC transmission lines steady-state induction issuesIEEE Transactions on Power Delivery, 1989
- Field and ion interactions of hybrid AC/DC transmission linesIEEE Transactions on Power Delivery, 1988